299 S Nautical Blvd 2013 HVAC '51 0 �
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002580 Date 5/01/13
Property Address . . . . . . 299 S NAUTICAL BLVD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 2 . 5 tons
----------------------------------------------------------------------------
Owner Contractor
------------------------
------------------------
ROBERTS, KIMBERLY A ONVILLE OCEAN STATE HEAT & AIR, INC.
299 S NAUTICAL BLVD 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 249-8251
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 10/28/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
900 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5945
JOB ADDRESS: 2-9 q A J PERAUT#
PROJECT VALUE S Y5 /V
NEW AIR CONDITIONING & BEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratinal.
T Total CFM REQUIRED
Duct S,stems:
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
A_Fd# .3(o*J-r,-73
Air Conditioning: Unit Quantity Tons Per Unit 21. �T REQVIRED
Heat: Unit Quantity I BTUs Per Unit y K.L.) Seer Rating____LT� ?_f
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinld- er System Quantity (Requires 3P sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underaround Fire Main Value (Requires 3 sets of plans)
Fire E17ose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
(Requires 3 sets of plans)
Fire Suppression Systems Quantity
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qt�,- Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantit�, of Outlets Pumps
4 Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tank-s (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and kmow the same to be true and correct. U provisions of laws and ordinances governing this work will be complied with whether specided
or not. The permit does not give authority to violate the provisions of anv other state or local law regulation construction or the performancff.ofconstruction.
Property Owners Name X-11 V-\ N)L-,_�r- -Phone Number 3 s-?, -j�,�j - o k
Mechanical Company OCcea_4A .. _-�5m-+f- hiq "A' - —Office Phone 2,yt-2zr i Fax z Y9 -W\i 9
Q Cit-yN,.o+v,,, A, �, State R- Zip 5 z-2-L L
Co. Address: (Y 7 So --k+( y to ----C_ - —
License Holder(Print): (rlezm T.-C State Ce onfRegistration4' C*cny93jv
Notarized Si,-nature of License Holder 10
3-w and sub�!Iu e day of -
=TM p.MORALES
YVE
t40TARY PUSM Sign f Notary Publ
STAM-OF FLORIDA
Val Como*Err
S79i74
ACCA Manual "J" Heat Load Calculation Date. 04/30/13
Customers Name Roberts Location Atlantic Beach
Type of Construction Heat Transfer multipliers Area or BTUH
Exposure Notes HEATING COOLING Length HEATING COOLING
1 Gross Wall 1,580
2,3 Windows
North Al, N, 2 29.0 16.0 15 435 240
East& West Al, E &W, 2 29.0 46.0 112 3,248 5,152
South Al, S, 2 29.0 25.0 20 580 500
4 Doors
Front Solid Wood - Pariel 27.0 15,8 30 810 474
Patio Solid Wood - Storm 16-4 9.7 60 984 582
Other SIdg GI Dr, S, 2 32.6 25.0 0 0 0
5 Net Wall
Area I R- 11, 1/2"Asp. B rd. 3.2 1.9 1,343 4,298 2,552
Area 2 R- 13, 1/2"Asp. Brd. 3.0 1�8 --- 0 0
Area 3 R- 13, 1/2"Asp. B rd. 3.0 1.8 0 0
6 Ceilings
Area I Attic, R-22 1.9 2.1 1,580 3,002 3,318
Area 2 Attic, R- 19 2.1 2.3 0 0
Area 3 Attic, R- 19 2,1 2.3 0 0
7 Floors P
Area I Slab 40.5 &0 167 6,764 0
Area 2 None 0.0 0.0 0 0
8 Infiltration Winter Summer Avg Cilng Ht
Poor 1500 - 2100 1.2 0. 1 9 6,387 3,135
9 Sub Total BTUH Loss 26,507
`0 Duct BTUH Loss 2,651
11 TOTAL HEATING LOAD 299158
'12 People and Appliances Bedrocms 3 3,000
13 Sub Total BTUH Gain (Structure) 18,952
14 Duct BTUH Gain Location Attic 15% 2,843
15 TOTAL SENSIBLE 21,795
16 Infiltraton Latent Gain Infit. CFIVI 142 4,941
17 People Latent Gain # People 4 980
19 TOTAL LATENT 5,921
19 Total Cooling Load 27,717
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
an ILI CERTIFIED,. J j between Feb 17, 2009 and Dec 31, 2013.
Lwww.ahri d I rectory,org
Certificate of Product Ratins
AHRI Certified Reference Number: 3645736 Date: 4/30/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 25HBC530A*k3O
Indoor Unit Model Number: FV4CNFOO2
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: COMFORT 13 PURON HP
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 28200
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.25
Heating Capacity(Btuh) @ 47 F: 27800*
Region IV HSPF Rating (Heating): 8.50
Heating Capacity(Btuh) @ 17 F: 16800
it
I I
*Ratings followed t)v an asterisk(')tridic ate a volunl,iry rer3te()f preVIOUSly PLIblished da'a,uriless&-companied v4uh a'VA S. vdiid)it)dicait's an involiontory i�,:Ite_
ISCLAIMER
sentations,warranties or guarantees as to.and assumes no responsibility for.
AHRI does not endorse the product(s)listed on this Certificate and makes no repro
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind ansing out of the use or performance of the product(s),orthe
unauthorized alteration of data listed an this Certificate.Certified ratings are valid only fot models and configurations listed in the directory at wwwahridirestory.ora.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not.in whole or in part,be reproduced;copied�disseminated;entered utto,a computer database;or otherwise utilized,it,any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION -iry,org, Air-Conditioning,Heating,
The information for the model cited on this certificate can be verified at wvtw.ahridirect,
click on link and enter the AHRI Certified Reference Number and the date on Oil ILI and Refrigerotion Institute
which the certificate was issued.which is listed above,and the Certificate No.,which is listed below.
@2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130118335096864847