Loading...
299 S Nautical Blvd 2013 HVAC '51 0 � CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002580 Date 5/01/13 Property Address . . . . . . 299 S NAUTICAL BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2 . 5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ROBERTS, KIMBERLY A ONVILLE OCEAN STATE HEAT & AIR, INC. 299 S NAUTICAL BLVD 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 10/28/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 900 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5945 JOB ADDRESS: 2-9 q A J PERAUT# PROJECT VALUE S Y5 /V NEW AIR CONDITIONING & BEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratinal. T Total CFM REQUIRED Duct S,stems: REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION A_Fd# .3(o*J-r,-73 Air Conditioning: Unit Quantity Tons Per Unit 21. �T REQVIRED Heat: Unit Quantity I BTUs Per Unit y K.L.) Seer Rating____LT� ?_f Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinld- er System Quantity (Requires 3P sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underaround Fire Main Value (Requires 3 sets of plans) Fire E17ose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) (Requires 3 sets of plans) Fire Suppression Systems Quantity FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qt�,- Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantit�, of Outlets Pumps 4 Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tank-s (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and kmow the same to be true and correct. U provisions of laws and ordinances governing this work will be complied with whether specided or not. The permit does not give authority to violate the provisions of anv other state or local law regulation construction or the performancff.ofconstruction. Property Owners Name X-11 V-\ N)L-,_�r- -Phone Number 3 s-?, -j�,�j - o k Mechanical Company OCcea_4A .. _-�5m-+f- hiq "A' - —Office Phone 2,yt-2zr i Fax z Y9 -W\i 9 Q Cit-yN,.o+v,,, A, �, State R- Zip 5 z-2-L L Co. Address: (Y 7 So --k+( y to ----C_ - — License Holder(Print): (rlezm T.-C State Ce onfRegistration4' C*cny93jv Notarized Si,-nature of License Holder 10 3-w and sub�!Iu e day of - =TM p.MORALES YVE t40TARY PUSM Sign f Notary Publ STAM-OF FLORIDA Val Como*Err S79i74 ACCA Manual "J" Heat Load Calculation Date. 04/30/13 Customers Name Roberts Location Atlantic Beach Type of Construction Heat Transfer multipliers Area or BTUH Exposure Notes HEATING COOLING Length HEATING COOLING 1 Gross Wall 1,580 2,3 Windows North Al, N, 2 29.0 16.0 15 435 240 East& West Al, E &W, 2 29.0 46.0 112 3,248 5,152 South Al, S, 2 29.0 25.0 20 580 500 4 Doors Front Solid Wood - Pariel 27.0 15,8 30 810 474 Patio Solid Wood - Storm 16-4 9.7 60 984 582 Other SIdg GI Dr, S, 2 32.6 25.0 0 0 0 5 Net Wall Area I R- 11, 1/2"Asp. B rd. 3.2 1.9 1,343 4,298 2,552 Area 2 R- 13, 1/2"Asp. Brd. 3.0 1�8 --- 0 0 Area 3 R- 13, 1/2"Asp. B rd. 3.0 1.8 0 0 6 Ceilings Area I Attic, R-22 1.9 2.1 1,580 3,002 3,318 Area 2 Attic, R- 19 2.1 2.3 0 0 Area 3 Attic, R- 19 2,1 2.3 0 0 7 Floors P Area I Slab 40.5 &0 167 6,764 0 Area 2 None 0.0 0.0 0 0 8 Infiltration Winter Summer Avg Cilng Ht Poor 1500 - 2100 1.2 0. 1 9 6,387 3,135 9 Sub Total BTUH Loss 26,507 `0 Duct BTUH Loss 2,651 11 TOTAL HEATING LOAD 299158 '12 People and Appliances Bedrocms 3 3,000 13 Sub Total BTUH Gain (Structure) 18,952 14 Duct BTUH Gain Location Attic 15% 2,843 15 TOTAL SENSIBLE 21,795 16 Infiltraton Latent Gain Infit. CFIVI 142 4,941 17 People Latent Gain # People 4 980 19 TOTAL LATENT 5,921 19 Total Cooling Load 27,717 This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service an ILI CERTIFIED,. J j between Feb 17, 2009 and Dec 31, 2013. Lwww.ahri d I rectory,org Certificate of Product Ratins AHRI Certified Reference Number: 3645736 Date: 4/30/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC530A*k3O Indoor Unit Model Number: FV4CNFOO2 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 28200 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.25 Heating Capacity(Btuh) @ 47 F: 27800* Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 16800 it I I *Ratings followed t)v an asterisk(')tridic ate a volunl,iry rer3te()f preVIOUSly PLIblished da'a,uriless&-companied v4uh a'VA S. vdiid)it)dicait's an involiontory i�,:Ite_ ISCLAIMER sentations,warranties or guarantees as to.and assumes no responsibility for. AHRI does not endorse the product(s)listed on this Certificate and makes no repro the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind ansing out of the use or performance of the product(s),orthe unauthorized alteration of data listed an this Certificate.Certified ratings are valid only fot models and configurations listed in the directory at wwwahridirestory.ora. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not.in whole or in part,be reproduced;copied�disseminated;entered utto,a computer database;or otherwise utilized,it,any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION -iry,org, Air-Conditioning,Heating, The information for the model cited on this certificate can be verified at wvtw.ahridirect, click on link and enter the AHRI Certified Reference Number and the date on Oil ILI and Refrigerotion Institute which the certificate was issued.which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130118335096864847