Loading...
330 Country Club Ln 2013 Screen Enclosure SSS CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002574 Date 5/03/13 Property Address . . . . . . 330 COUNTRY CLUB LN Application type description SCREENED ENCLOSURE Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 11900 ---------------------------------------------------------------------------- Application desc Screened pool enclosure ---------------------------------------------------------------------------- Owner Contractor PARKER EARL W JR & LEYA M ALL PRO ENCLOSURES INC 505 BASSWOOD CT 582 ST JOHNS PARKWAY JACKSONVILLE FL 32259 ST AUGUSTINE FL 32092 (904) 962-3032 ---------------------------------------------------------------------------- Permit RESIDENTIAL ALT/OTHER Additional desc . . Permit Fee . . . . 110 . 00 Plan Check Fee 55 . 00 Issue Date . . . . Valuation . . . . 11900 Expiration Date . . 10/30/13 ---------------------------------------------------------------------------- Special Notes and Comments 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE *REPORT ANY UNFORSEEN STRUCTURAL DAMAGE TO THE BUILDING DEPARTMENT IMMEDIATELY. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE DCA SURCHARGE 2 . 00 DEV REVIEW-SINGLE & 2-FAM 50 . 00 STATE DBPR SURCHARGE 2 . 00 UTIL REV PRE APP >3 HRS 25 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 110 . 00 110 . 00 . 00 . 00 Plan Check Total 55 . 00 55 . 00 . 00 . 00 Other Fee Total 79 . 00 79 . 00 . 00 . 00 Grand Total 244 . 00 244 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. City of Atlantic Beach Building Department NUMBERart ment) 800 Seminole Road ' x ' Atlantic Beach, Florida 32233-5445 � >r�M Phone(904)247-5826 Fax(904)247-5845 3 E-mail: building-dept@coab.usp � -: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING. FORM Property Address: 133Qmdb�aA [p Deo rtment review required Ye o `/�� n C` A fiian�ning&Zoninci� Applicant: ' 1 ll ` sydtS lou, Tree Administrator Project: �� Cj`,fublic Works ublic Utilities Public 9996 Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept.of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: proved. ❑Denied. 1 (Circle one.) Comments: BUILDING PLANNING&ZONING Reviewed by: _Date: . -02—0 TREE ADMIN. Second Review: . ❑Approved as revised. ❑De PUBLIC WORKS Comments: PUBLIC UTILITIES l PUBLIC SAFETY Reviewed by: Date: ! FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07127/10 RPCEIVED P a a City of Atlantic Beach T � MICATION NUMBER Building Department MAY 01 2013 ' o be assigned by the Building;Depaitment.) <. 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.usxDati� City web-site: http://vwm.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3�0 CC1 I l� �'� 0 09 L 1 __ e a ent review required Yes No I Pyy)- c' fI BuilApplicant: { Gnl�) �u �� �� tanning &zoning �q� r�rTi� -�,nr 1 �cf ' Tree AcIminfstrator Project: Sy, A�'vyI Cir �, �-x� pub l' Pu icUfilities ; Fire Servi^e5 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: �Approved. ODenied. (Circle one.) Comments: _,,n BUILDING �l/�� l lI PLANNING&ZONING Reviewed by: Date: �Z TREE ADMIN. Second Review: []Approved as revised. []Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07f27110 J City of Atlantic Beach RCFTVED # A�FI� ATION?NUMBER Building Department :.? n be assigned by to Building Depaitment) u 800 Seminole Road MAYO 12013 Atlantic Beach, Florida 32233-5445 iI Phone(904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us __ - Daerouted}A' -.t City web-site: http://www.coab.us APPLICATION REVIEW AND TP CKING FORD Property Address: 350 C lU19 D 1 Department eeviiew required Yes No Buildin Applicant: ' 'r -Xnc-� 'Planning&Zoning � Tree Administrator Project: _ayjC_r )l�; Public W 'Public Public e Fire Services Other Agency Review or Permit Required Review or Receipt pate of Permit Verified B Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Div sion of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS j Reviewing Department First Review: 6pproved. [Denied. (Circle one.) Comments: !!! BUILDING PLANNING&ZONING Reviewed bY: Date: ' 3 TREEA MIN. Second Review: J ❑Approved as revised. ®Denied. P ORKS Comments: P LIC UTILITIE PUBLIC SAFE Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: I _ Reviewed by: Date: ii Revised 07/27/10 City of Atlantic Beach I�CSATION��NUMBER Building Department (To beassigrred5b thW Building Depaitment) r 800 Seminole Road71 Atlantic Beach, Florida 32233-5445b �;� . Phone(904)247-5826 Fax(904)247-5845 ,� £t` 1 ' zQ E-mail: building-dept@coab.usD'atefouted` City web-site: http://www.mab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 3 3rd C ' ( 6 l► J O LW L+) De&artment review required Yes No _ Build' Applicant: 6 ' '�� � �-�C/, ing &Zoning afor Project: u, Public orks ublic Utilitse -Pt�blie-Saf Fire Services .00 Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept.of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcohoiic Beverages and Tobacco Other: — APPL CATION STATUS Reviewing Department First Review: Approved. QDenied. ' (Circle one.) Comments: PLANNING&ZONINGDate: �01 Reviewed by: Date: / 248 TREE ADMIN. Second Review: QApproved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: i Reviewed by: ....�. Date: — I _ ,.__.__-.�_..�..._�._._.._..._..� � Revised 07/27/10 rzt.,,...... ..." BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH E1 i. E COPY 800 Seminole Road, Atlantic Beach, FL 32233 APR 30 2013 Office (904) 247-5826 Fax (904) 247-5845 ILJY Job Address: 330 (foun C 1 l_ ate Permit Number: 1 _2_52 t' Legal Description a?-G /G —2 S —24 E Se1$2c, M ei U '*�,Z Parcel# Floor Area ot q. t. 'q F't Valuation of Work$ 1/1 f 00 Proposed Work heated/cooled non-heated/cooled /RAL/ Class of Work(circle one): New ddition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s) circle one): Commercial If an existing structure,is a fire sprinkler system installed? (Circle one): Yes No N/A Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed: SC r-ejo0n\ enc lckS uf'k Property Owner Information: Name: !Po.r V_eq- Fog- L Address: 5o S Qa S5 wood C4- City 31- U-it. n 1 State _Zip _D4.5 Phone G t - 52Y71 E-Mail or Fax#(Optional) Contractor Information: Company Name: 40 Pro AclaSaresF 27nr- Qualifying Agent: W(-S<<y M,t h'he )-5 Address:5-9.2- 3_oh4 Creek PCity 5h State Fz- Zip 320 92_ Office Phone Job Site/Contact Number qo% 96 2-36 3 2, Fax# Z3o-�/Y8 3 State Certification/Registration# C&_12,51370 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address SAMC Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installati�Oda s as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standarlllawthis jurisdiction. This permit becomes null nd void ifwork isnotcommened withinix(6)monthsorif constructnork is suspended or abandoned for a period of stx6)months at any time after work is commenced. 1 understand that separate permits must be secured for Electric Work,Plumbing,Signs, Wells,Pools, Furnaces,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. 1 hereby certify that 1 have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type o work will be complied with whether sped ted herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state, or local law regulating construction or the performance of construction. Signature of Owne Signature of Contractor Print Name L- r ✓ Print Name .......... ........a.......�G ................................................................ ti,/ .Cp ..... I .th e�v ........................................... Sworn to and subscribed before me Sworn to and subscribed before me th', �1 O'Day of If/0h,� 20 �� this �Day of -1 20 !3 EN MARY MCLEOD Nota IC-SUr rL Notary Publicnrly, Somnitz '= MY COMMISSION#DD984996 `Commis ion#DD96588tevised 01.26.10 EXPIRES April 25,2014 E; .' Fprey FEB.25,201 (407)388 015 FIaWalloter Service mr, CBONDINGCO-,INC. " BONDEDTHRIJ ATLANTIC NOTICE OF COMMENCEMENT State of !` �Tax Folio No. County of ✓dl, FILE COPY To Whom It May Concern: +�. . The undersigned hereby informs you thatu�r:�ra�# ��d+� ay real property, and in accordance with Secrion 713 of the Florida Statutes,the following information is stated in this NOTICE OF COMMENCEMENT. Legal Description of property being improved: N l 60 A&Ck A-1VA 1YI&I—II 64G f 2- Address of property being improved: >C3 General description of improvements: P061, Ehd 65 c-rZ-it Owner: Address: So,5 Ras,S WG4 O"• 3 0"rk 7CL 2 255 Owner's interest in site of the improvement: rLe 5 t l e Fee Simple Titleholder(if other than owner): Name: Contractor: A\\ ere-, Address: 5q2 5okn-5 Cr:eC)e—' Pik-tlja5 V sfvrf2 E FL .3Z�I Z Telephone No.: %dy-Q6 2—3 3 Z Fax No: qOq- 230 Surety(if any) Address: Amount of Bond$ Telephone No: Fax No: Name and address of any person making a loan for the construction of the improvements Name: Address: Phone No: Fax No: Name of person within the State of Florida, other than himself, designated by owner upon whom notices or other documents may be served: Name: Address: Telephone No: Fax No: In addition to himself, owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statues. (Fill in at Owner's option) Name: Address: Telephone No: Fax No: Expiration date of Notice of Commencement(the expiration date is one (1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY OWNER Signed: 'ti Date: Before meth is day of in the County of Duval,State Of Florida,has 74- "°cumber Pages: 1 vly personally appeared Y Doc#2013106806,CR B;{1 - PNotary Public at Large,Sta of Florida,Co uval ✓1/L; � Page`"g4 Commission expires: Recorded 04/30;2013 at 10:41 AM, ?ersonall own: fJ(CLEOD Ronnie Fusseil CLERK CIRCUIT COURT DUVAL ro uced Idenf cat}.. COUNTY ( ! EXPIRES April 25,2014 RECORDING$10.00 *: MY C()A, 4 , 153 FlaiAeNde Servia.com EXPIhz. I � DEN - C b RY CLUB LANE r FLO �o� SF= 2-2, 651 - 7- 31 a e alt 5Q-jjcSe- a.5ure- sex ------------- i -nft'3ch� 'nd Tonin (4parttnent _ t fi5 ComE ante with appl;CaNe �. Sfjbdvs:'•on 8fi €>t}}f-i 1Qi:ai µF b t d{. ROt w 1 °7 f f,,-the Is,t a"ice 0 per1 3 '"gyp t a t>tital -w, C,o.4e d o$A othe a, 3Y.te Feder 11 pirmitting rer reg r<t� rR "Nr Arlt? yi " t9t4e=€�+t+�o`;Atlantic c Llif'�U,_. to the assLance at •- r O 2x8 SM 2x8 SMB a! � 2x8 SMB41 —s n J �'• p Q re•^W+ss vp v 2x8 SM x N O < ry z O O 0 2x8 SMB ®vl 0 u cr � N _Z � c —m v 0 c� 3 v 0 0 • • • (n �M�+JI � cD OD J O)U A W N • D "" to 0C�3d f/1DN An O 2lT100 C k�y Z a a, D D S. cam D� <° r ruc m rn� n 'w � m B 3 �:3 3 Q n o m o ° O N m nry c-S N uri v n N O= w O m a,<O N (D O j Z O d Co 91 7 Ol pp< 6,I v y d N ND7 ry 0 �p aC d p til x(� N — (/I d y a-v d N O n 0 N J N O d N N 01 0 O dO 7 NUCO (G (n �. UO v.v N (D 9 O 0 N 'o�mo '3 m 61 i Q .N. 3 Xdo N O Q N�N NzN O ^ �gx DN 3 or r^ paw rn 0 No o a Q o r it '� j O O o� Oo cn `N\\ltllttt:i."i.'l f�!///' y 2 Omoo b o T" V lai \ •I�GI� 3 = °„r�irrlttlnttttlti�`�` PLAN VIEW Revisions: Parker Cleve E.Dryden,PE IIIIIo Count Club Lane 3518 Fortuna Drive 33 n' Orange Park.Florida 32065 Atlantic Beach,F132223 sc•a:maoma Deaipn:cED 904.9556302 _, � Data:al2]It] Drawn: - �nN.lvAt],\iY-Ln]\�•YV��-I_T.yq O N �-r O O r2x5 5M m n LL M QN a< 2,,5 VIB -D '{ z o r z —< Z\0� 2 2x5 SMB N - B 2x5 5M 2x5 5 B 2x5 5MB N x N N O O 2x5 5M TI O X Q r 2x5 5MB °�z i 2-6-z' Qz 4-0 2x�5�85M13 2x5 B 2x5 5M7a 2x5 5MB OT 2x5 5MBNn / 2x5 5MB 2'-6' = N D N m -r R 2x5 5M O Z 2x5 5MB - L i fl.. g f: �" •'Ylilliit 11�' O A ELEVATIONS Revisions: Parker Cleve E.Dryden,PE 3518 Fortuna Drive 330 Country Club Lane orange Park.Florida 32065 - Atlantic Beach,A 32223 904.955-6302 s,me:As rroreo Design:e¢o N I Dare 4123113 Dr,.n: — a.oi��,no.. Cne keep cED o.:.�ub• sM.*...mV�'-amt�w+.N�V-x-•awa o.r1w N z M0 am O Z CO 12" 80 O Z CO Cf) DwO=—OZzI it•;'Ai.�,�3r ♦ s•° ns 4�°•• 1•° � -•nn mENN arnow�0�00O p 9QNm Dm 0 ' �t � cx p M 9- 5'.. ra T m m crnne — 0 • G0Z 00DT �0 CO'00 wm Z �mom00z o ao 0 0of n O O L ZZZ CCC) O OO p (O i Cl) n O tO m ® o O D O OO 21 �dln. 0A • �--�i z ° • 16" _ grn m4 s ---��j l l i ° • - N OND v I I C m O OA • x z • 2—I D D —I ZmiO • n A 0m 0 :L1 0 n s e A D O m 00 • . ♦ ° 0 1071 m Z Z m Q D D U Jm �m-n z V) Mp a CO N C mg JO O � K CO 0 7x _ 3" $ 0 ' 1 m � r O Si B N O 2 2'MIN. 0 a)> li S. �m ro x Z c'o 9 m O >N\\\ a t z tl0 0 0 s U) p 11 11 II a3 • 4g a 1n m 8 .o $op s00rn 3 See Plan �Z T ��z N z DDS ug m -On p ZZ� o o D 0 C 3�za�N 3 0m ' Cc- �xx Z m ow f,3;3 C Ri.. m^ 0 N N CU 0Q1 - Cf) S m m7 x i a r74„a ? 4141it1 0 m .T�l J I M D o w_ zZZ5 o 0w > 0 i A D 43 T i 10 r O a • O ti x ' Z O O N O COrt STRUCTURAL DETAILS Revisions: Parker Clave E.Dryden.PE K c o Coun Club Lane 3518 Fortuna Drive 33 1� Orange Park,Fonda 32065 Atlantic Beach,Fl 32223 904.955.6302 w SuN:•S Ro7FD DNlpm CEO DOW 923R3 D—RD - W •r.xF mu-�:am.:-uaa a... _�.:n....a+VT-ann•.i.N.�V-a-�a.s orw.av wrn A°)w 0 o NH \ O' N O 2 7 w e3 A\5. K �� ����p3 3 s .3 u-a 3 o N m ao C D. m m a N m 3 2- m 7A0 N Cp (7 S J O m 8 o z o � Z -} Z E: {• � y3� - X a Q z a a u A O(A m xNNNg ZW(A omm� 3 + cam A = R p w ° n m n = r N IT N v � m N MIM 0 c O OD OD 01 O W-1 LO 17-- -a v z mm A W ° � "av,� m D r Cam rr� () p fD D D 0 0 =n n� LTJ �aD v rn = m � -rt*Z W co x Ln O NM ZII++77 �� �^ r vx m ? m ZZy NZ Ort Z-i �� m n p SCO 'ONV ON r-;V D � zm R°N= �(b OD Nf N � D O�� V) NOD O a N D 0 O m 0Nm m W z N V) I' o rnaww o C) e o ' O Z m z El C7 m ° Cm r- o o z�cn v .0D O rt��-1-+ O- o porgy CO ° O z (W*1 O'X D\N X -i D $ CNomz.-4-r �' m. z O N ? �7 m" in �zr' Ov _ z n0n�mm U.1411 `A r"m p " 47 o w ' ...I �nrmi �D y N o_ II Q mn�Z\�_N 0" �O � 5' q M N O -0 a m 0 ^ m O O m 0� '� �g D ov(n F Z7►�z 2Z 7 m Z o m ' a o c O 3 c r II{Ii}t�' STRUCTURAL DETAILS Revisions: Parker Cleve E.Dryden,PE ° 330 Country Club lane 3516 Park,rtuna Drive Orange Park.Florida 32065 Atlantic Beach,Fl 32223 scar.:�s R)TED D••i•n:cm 904.955.6302 Dow:4r2111] D—:RWD Parker Design Calculations BEAM SPAN TABLE Eave l►t(lt Mansard Return 00 Material Specifications Full Man 10 4 0 Aluminium Extrusion 6005-T5 Purlins 6.07 Materials based on E= 10,100,000 psi Ftu= 30ksi (ATM Part 1ATable 3.3-1) Code: 2010 FBC ASC:7-10 Flc 25ksi WS from Chapter 16(Cat 1) Atlantic Beach,Fl 'Wind Speed I fltimate/LRFD Design Pressures RF ASD Mesh Design I,oad 120 MPH Exposure Factor 0.6 0.88 Location Design Pressures B Separate Analysis for all Pri►n uy Structural Members Windward Wall 20 psf 300 LBS Concentrated Livel oad LCC%%'u-d Wall 1 5 psf (No combinations) Root' 6 psf 1 1 200 lbs pt.load on purlins Veritcal Solid 17 psf Risk Category I (1604.5) Using 18x11•x.013 mesh o►n Rool' Allowable Spans SMB Sections(Stitching at 24"to 2x8) (2x9&2x10 @12"Stitching) SMB Sections Bending Stress(ksi) Vertical Uplift O► Spans(Moment fb) Size 28 30 32 34 36 38 40 Fb (Allow) 2x,I 25.1.5 29.21 33.21 37.52 12.06 46.87 51.9:1 9.300 2x5 16.85 19.34 22.01 24.85 27.86 31.0.4 34.31 10.100 2x6 13.09 15.03 17.10 19.30 21.64 24.11 26.71 9.100 2x7 10.49 12.0.4 13.70 15.47 17.34 19.32 2 1.4 1 9.400 2x8 5.73 6.58 7.48 8.1.5 9.47 10.55 11.69 16.300 2x9 4.16 4.77 5.4.3 6.13 6.87 7.65 8.48 20.180 2x 10 3.01 3.15 3.93 4.1•,9 4.97 5.54 6.11-1 20.660 Point Load(300 lbs Live Load) @ Center of Beam Size 28 30 32 34 36 38 40 Fb(Allow) 2x,4 2,5.20 27.00 28.80 30.60 32.40 34.20 36.00 9.300 2x5 16.69 17.88 19.07 20.26 21.46 22.65 221.8 4 10.100 2x6 12.96 13.89 14.81 15.71 16.67 17.59 18.52 9.100 2x7 10.39 11.13 11.87 6.89 13.36 14.L 0 1 I-A t 9.400 2x8 5.67 6.08 6.49 6.89 7.30 7.70 8.11 16.300 2x9 4.12 4.41 4.70 5.00 5.29 5.59 .3.88 20.180 2x 10 2.98 3.19 3.1.0 3.62 3.83 4.04 4.25 20.660 Ib- FcOly l7,c•y- 30 ksi Analysis Based on 6005-T5 Aluminum Material fly= 1.65 Isize I 2x6 2x7 2x8 Determine Allowable Bending Stress AlloNmble bending Stress 9.1001 9.400 16.300 18.18 ksi S<S 1 Allowable Shear Stress- 1 3.281 5. 21 7.57 12.5 ksi S 1<S<S2 Specific Calculations ASD Loads Beam Bending Load Width(fl.) Span (11.) Load(lb/It) M(K-in.) Total(MI' Iwil., ► ► 6.83 36.50 Bending(V00 21.64 13.24 .53. 4° 6.83 36.50 Liveload(lbs) 300 32.85 32;,68 2.9 .S xC 5.83 9.83 Bending W 18.47 2.68 1:3 NX5� 5,83 9.83 Liveload(lbs) 300 8.85 84 ;5'2. .3 •. n Calculations ���f�//o��sSi'ONiAI�����`��� Page Design `����I1111111111t1N����� Parker Design Calculations 7.85711 28.33 1 Bending(W)1 28.29 1 34.05 1 44.711 10.07 0.3,=1SX8 7.851 28.331 Liveload(lbs)1 300 1 25.50 25.50[_ 5.74 3.46 1 S2X8 Mansard Preferred Stiching for 2x9SMB is 12 inches. Beam Support Allowable A Actual A Sire(SMB) Point (,Airld) 5.48 In 3.14 In S2X8 Wind Load Fixed F,nd Dead Load 1.00 Lb/ft. 1.63 lu weight of material= 1 lbs/ft. <6.45 Inches-OK Beam Support Allowable A _Actual A Si%C (SMB) Point(LI.) 1.97 In 0.06 Ia Uniform (Wind Load) 0.02 In Bcarrr/Post S2X8 2x5SMB Total Verticil Pressure UFO WOO Ali(sl) Load(psl) POW 47.83 36.50 1745.795 3.6 6284.9 Vetical Reactions(lbs)-Front Wall 747.9 Vertical Reactions (lbs)-Interior Beams L(lt) Pv Pdl V-Reaction 36.50 6.00 0.7 747.885 Vertical Reaction(lbs)Corner Column 747.89 Non-Flow Thm Loads Horizontal Reaction Summary Host 972.2.5 First Two Host Beam Connections (Couple) Front 0.00 Force In at each Return Wall Horizontal Pressure Ht.(ft) W(ft) L(ft) Man(ft) Ain Awn Avn 10 18.33 17 4 240.66 70.66 311.32 Total Horizontal Non-Flow"Ilim Load(lbs) Supports 4047.16 5.41 lbs/support 747.885 Horizontal Forces at Middle of Front Wall h F111 273.20 13 3551.60 1-h2 546.40 12 6556.80 x113 887.90 6.25 5549.38 Ft(Ibs) 1707.50 1957.22 Hf(lbs) -249.72 Summary of Host(H)and Front (F) Horizontal Non-Flow,rhru Loads(lbs) H1 112 H3-H10 H11 H12 972.25 0.001 19.37.22188 0 972.25 Fl Fl F3-F10 F11 F12 0.00 -499.44 Z 19.72 -4,99.44375 0.00 Flow 1 hru Horizontal load Page 2 Design Calculations Parker Design Calculations Vertical Projected Area Awf AS Avf 183.30 54.99 238.29 Phf 3574.4 lbs 'Total Flow Thru load Fir-host 1374.75 lbs Moment 0.00 lb-ft V-Rea(ion 0.00 lbs Vertical Reaction Summary-Flow'Tluu(lbs) Location Windward Leemuxl Middle 0.00 0.00 lbs Pull Out Force on Existing Structure at Each Connection Point Post Connection to Concrete Load Uplift Load Width (pst) Lo-,ml Limit(lt) "Total(Lbs) 4-1/4" SF F-up 6.83 6 9.165 375.6 3200.0 9 F-OT 6.83 20.00 5 683 4,000 6 Vertical Wind 630.00 lbs /connection 5040 Total Vertical Force Shear 300 lbs 2700 Lave Load Front Post Support Design-Axial Compression+Bending Type Height(lt.) 101) Ht.Total Sim 2x5SMB 10 -1• 14 2x5 2x6 2x7 2x8 Area- 1.23 sq.irn. lb(ksi) 8.1 1, 6.32 5.07 2.77 Colurnrn Stress I fa(ksi) 1.82 1.64 1.36 0.91 Desigu Loads k spall(11.) Total Def-(in) 1.52 0.54 0.36 0.18 P-Max 0.75 36.50 3346.7 lbs Max.Moment 12.3 In-Kips Def.Allow 2.10 ft-lbs Max.P 1673.35 lbs Allowable k= I Fc(allow)- 14 Fb(ksi) 9.30 9.10 9.10 16.300 ra 2.99 2x4 Fa(ksi) 1.151 1.538 1.517 2.200 la 120 fc(act)- 2.139 Fc(K) 1.056 1.571 INA 1,06.1. kl/r- 40.1 60m Carry Beam 2x7 SMB Vertical Load 3.2 lb(ksi) 23.04 in-kips 0 ksi 9.50 Span 16 ft Max Mo. Load Width 8.000 It Allowable 2.40 inn 0 Horizontal Mtot(in-k) Beams Beaun M lby(ksi) Page 3 Design Calculations Parker Design Calculations 60 23.010 15 1.51 1.26 Allowable Fh= 0.000 lbs Ream 20 2x8 2x9 2x 10 Allowable rb (ksi) 9.400 15.013 20.180 20.660 Mlia 0.000 in-kps Stress 11)(ksi) 9.50 .5.19 3.76 2.72 LL def(iii) 0.52 0.26 0.16 0.10 Wiud-Vcrt dcl*(in) 0.83 0.42 0.26 0.17 Check Buckling rcy= 35 ksi S I3c Dc Cc ny- 1.6.5 FC- 15.152 ksi Allowable S<S1 8.596 8.7 0.031 185 Fc- 3.05 ksi fc= 0.18 ksi A S 1- 64.35047852 S2= 13369.14063 Posts provide adequate resistance to the applied load conditions. Girt Member Design (Chairrail) Horizonl;d WindLoad M-w I x(3L.^2-,la^2)/2,1+w2(3L^2-4a2^)/24 wl (in-lbs) w2 (in-lbs) L(in) J al (in) a2 (in) sl (in) s2(in) p (psfl 2.19 1.875 81.96 21 18 42 36 15 3.15 300Lb Liveload largest P I, M (in-k) Largest Shear 200 81.96 4.098 0.3 R -QUIRED Size F)(ksi) Sx(in^3) Sx-Wii i SX-Ll. I�t (111^j1) I)OAV tin) 1A.1•-1.1. ,2\2 Ui 0.2 1, 0.197 0.2(i � t►.11!t 't.11:-u!) l 2\,117.'2 o, Ift 0.183 0.21 � rl..;!>�� l.lt�. In o-36.1) 0,177 R� �) 2%1 0.193 0.` 5, 1.271 2-;l- Ill 0-169 t1,?(i7 lti.:3 ti 1. - Deflection Check Allowable bmw 1.02.5 In. 98708797 22.37 0.07 2215317,1.91.21 84607541 23.07 0.01 19.5.5103964 4170421455.15 Page 4 Design Calculations Parker Design Calculations Perlin Check Horizontal WindLoad M-wl x(3L^2-Oki^2)/2d,+w2(3L^2-,i,a2^)/2,1 wl (in-lbs) w2 (in-lbs) I,(in) al (in) a2 (in) sl (in) s2(in) p(psf) M (In-k) 0.51 0.51 72.84 18.21 18.21 36.4`2 3(1.42 4 0.62 3001,6 Liveload Concentrated load Largest p I, M (in-k) Largest Shear 200 72.81. 3.642 0.3 Ri )UIRI:1) Sec 1•b (ksi) Sx(iri^3) Sx-Winn �c-LL i l(i L1^4) t)rf t1 (111) D. 2\2 1 .038 0.`23 U,Ii�) ?t,lh. t1�1 i�.11i`1 T _ 0.036 0.21 (L,;it 1.tV-t;t ,,, 0.22 - 14239253 22.50 0.06 321273136.18 14239252.57 22.50 0.06 321273136.2 642546272.36 Deflection Check Allowable 0.911 In. Foundation Load: "burn down section Load Area Load Area D+I, Lbs/ft Fooling Area Load(lbs/II) Vertical Load 1250 10.7 13375 33.5 399 Stress on Tunidoam Section Wind Load 1250.00 6 7500 33.50 224 Stress added by Wind Max Stress 623 YSF Horizontal-Load Windload YSF Hor-Wind F Ht. W Load Area WL(Lbs-) Hor Supports 35 14 6.83 9.5.62 3316.7 Footing Stress Depth Width(ft) Length(It) Stress(psl) Allow�il�le(psl) 0.67 0.67 17 35.1 2000 Check Uplift Weight(lbs) Length(ft) Width Depth Page 5 Design Calculations Parker Design Calculations Footing 54.5.01 17 0.67 0.33 NR Slab 28667.10 17 36.50 0.33 Patio Slab Structure 2500 Total 31712.11 Length(ft) Width Uplift (psf) Uplift 2233.80 17 36.50 3.6 0.tiD+\\'. 3730.4.55 OK SF' 8.50 Check Laterial Shear shear 900/anchor Uplift 800/anchor 1/4"with 2 1/2"embed(3"edge clearance) Tension 900 lbs/anchor same Sliding W L It. Load(PSF) F-s Connections Resistance 28.42 I L 28 11140.64 33600 Resisting Lbs DL Concrete 14396.4 SF- 2.0 3.0 Struct 4500 Host 3500 Total 22396.4 Overturning r1-0t(p50 Lit. (ft) Area(sl) Mo(ft-lbs) 28.0 20 570.4, 159712 Resistittg Mo(ft-lbs) SI' Slab 122,369.25 1 Connection 214,200.00 1 2100 lbs Use 1/8"Diameter SS Cable Rated Strenght RACKING LOADS Cable Needs Comer Cable Loads Parallel Host Dist. (lbs) H Width(ftJ \'indward(psl Leeward(ps0 10 36.50 20 15 0.25 1916.25 Corner Cable Load parallel to host SF- 1.6 1916.25 1 cables required ALLOWABLE 1/8"CABLE 1400;LBS OK 1-required SidcwapSupport Post Chcck Windl,oad (Horizontal) Wiudload(Vertical) 10 ft. Ld Width= 3.42�ft. H9 Ld Width6.07 11. Span= 6.07 ft. Page 6 Design Calculations Parker Design Calculations VIm.Lx.- 0.80 Ft.-Kips fmax.- 124.4 lbs 9.61 In-Kips Size Allowable Fb(ksi) lb(ksi) Fa(ksi) la(ksi) 2x4 9.300 9.61 0.58 0.159 2x5 10.100 6.37 1.06 0.136 2x6 9.100 4.95 1.57 0.122 2x7 9.400 3.96 1.86 0.101 Not Part of this cicsitm 0 Mlnax. (in-k) Support Column for Cant'Beam 0 Y(lbs) 178 lbs From Carry Beam (.300 lb LL) 300 lbs From SideKa ll Support Point Load Reaction Over Column from SW 478 Total Size Allowable 11)(ksO lb(ksi) Fa(ksi) fa(ksi) 2x4 9.300 0.00 0.58 0.611 2x5 10.100 0.00 1.06 0.521 2x6 9.100 0.00 1.57 0.-468 20 9:100 0.00 1.86 0.389 Alternate Design(Fixed Moment at Beam to Column Support) Not consider for this site Beam Design LI.- 300 WindLoad mi- 20.53 21.32 Center of Beam Mtiktx- 24.64 43.24 At Fixed Pouu Section at Centerline of Beam Sze fb 2x7SMB 10.03 `2x8 SMB 5.18 Page 7 Design Calculations Parker Design Calculations Compression Force on Horizontal Beam Comp 683 lbs 18% Bend 74% Total 93% Shoulder Reaction= 683 lbs Bending M (k-in) 683 Ft-Lbs 8.20 Leeward 204.9 2.46 Full Mansard Only Subtotal 10.65 SMB Properties for Design Major Axis b I d I tw tf A Ix Sx n Iy Sy ry S2X4 2 4 0.046 0.100 0.78`2 2.000 1 A00 1.600 0.470 0.171 0.775 S2X5 2 5 0.0501 0.116 0.917 3.644 1.510 1.993 0.592 0.592 0.800 S2X6 2 6 0.050 0.120 1.022 5.660 1.94:4 2.354 0.685 0.68.5 0.819 S2X7 '2 7 0.055 ; 0.120 1.229 8.472 2.425 2.626 0.849 0.850 0.831 S2X8 2 8 0.072 0.224 1.847 16.557 4.441 2.994 1.215 1.215 0.8109 S2X9 2 9 0.082 : 0.306 2.357 27.16 6.123 3.395 1.524 11.526 0.804 S2X10 2 10 0.092 0.374 3.013 42.28`1 8:462 3.746 1.926 11.926 0.8 6005T5 Results Member Fc Fa Fbx Mx Fby My 52X4 0.742 0.58 8.74 8.74 5.38 2.53 S2X5 1.151 1.06 9.20 13.90 6.08 3.60 S2X6 1.538 1.57 8.96 17.42 5.03 3.45 S2X7 1.517 1.86 9.19 22.29 4.72 4.01 S2X8 2.200 3.78 16.30 72.39 11.10 13.49 S2X9 2.300 5.42 20.18 120.97 16.45 25.10 S2-X10 2.512 7.57 20.66 165.41 1 20.71 39.88 Page 8 Design Calculations