Loading...
1670 Beach Ave 2013 HVAC h, CITY OF ATLANTIC BEACH- 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 -5814 INSPECTION PHONE LINE 247 Application Number . . . . . 13-00002628 Date 5/08/13 Property Address . . . . . . 1670 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------- ----------------------------------------------------- Application desc 4 tons 48K btu' s -------------------------------------------- Owner Contractor-------------- ---------- DONOVAN HEATING & AIR ESHELMAN THADDEUS 0 315 SIXTH AVENUE SOUTH 1670 BEACH AVE JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-378S ---------- ----------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc - - 107 . 00 Plan Check Fee . 00 Permit Fee . . . . Valuation . . . . 0 Issue Date . . . . Expiration Date . . 11/04/13 ------------------------- ----- ----- ---- - - - - - - - - - ----- -- -----Other-Fees STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------- ----------------------------------------------------------------- Fee summary Charged Paid Credited Due ----- ----------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT AppLICATION CITY OFATLANTIc BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOBADDRF,SS: i(�Io Ave- PERMrr# PROJECTVALUE$ 4,700a" NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditionmg- Unit Quant[ty Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM — - REQME1) REPLACEMENT AIR CONDITIONING & HEATING SySTEM INS # 51J Air Conditioning. Unit Quantity I Tons Per Unit q ARI "Um Heat Unit Quantity I BTU's Per Unit Seer Rating -.- Duct Systems: Total CFM REQUDZED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE P11ACES MISCELLANEOUS: Praffibricated Fireplace Qty_ Automobile Lifts Gras Pipmg Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTUs Water Heaters Solar Collection Systems Tanks(gallons) Wells 3THER: ermit becom es void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read lis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified r not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction- roperty Owners Name 7A141) PhoneNumber 40-�- lechanical Company tbz!r---+ j- Alo- Office Phone V1 1-31 KrFax -ZH I-3-19S- o.Address: 31'�;- ve- -S, City �)a,�t �:�A04 C k State fL_ Zip S.ID-5-b icense Holder(Print): Oanpvr-rN —State Certificafion/Registrafion# e-4 coY)-) 61 owdzed Skmature of License HoMer Sworn and subscribed before me this D dayof ffi4-� 20Q- 0" Notary Public State of Florida gnature of Notary Public. 51;al Timothy Lee Hughes �j %01, Expires D4/0312016 My Comniission EE 278 REM 186 fi Job: Project Summary Date: 5/6113 wrightsoft Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south, Jacksonville Beach, Fl-32250 Phone: 241-3785 Email brandon@donovanac.com Proiect Information For: Eshelmand 1670 Beach Ave, Jacksonville, FL 32233 Notes� Desiqn Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 'F Inside db 68 'F Inside db 75 'F Design TD 29 'F Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21477 Btuh Structure 17679 Btuh D ucts 7576 Btuh Ducts 15456 Btuh Central vent (57 cfm) 1804 Btuh Central vent (57 cfm) 1244 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Use manufacturer's data n Equipment load 30857 Btuh Rate/swing multiglier 1.00 Infiltration Equipment sensi le load 34379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2029 Btuh Ducts 2778 Btuh Heatin coolinp Central vent (57 cfm) 2047 Btuh Area (ft 2�ft. 2339 233 Equipment latent load 6854 Btuh Volume 21024 21024 0.38 0.16 Equipment total load 41233 Btuh Air changes/hour Req. total capacity at 0.70 SHR 4.1 ton Equiv.AVF (cfm) 132 56 Heating Equipment Summary Cooling Equipment Summary Make carrier Make carrier Trade Trade 25HNB648C Model 25HNB648C Cond ARI ref no. 5480779 Coil FE4ANFOO5 ARI ref no. 5480779 16 SEER Efficiency 9 HSPF Efficiency Sensible cooling 32292 Btuh Heating input 13840 Btuh Heating output 45903 Btuh @ 47'F Latent cooling Temperature rise 27 'F Total cooling 46132 Btuh Actual air flow 1538 cfm Actual air flow 1538 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0,83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. — Right-SuiteO Universal 7.1.01 RSU05996 2013-May-06 11:54.22 C:\Us ers\Sales\D ocurn ent s\Wright soft HVAC\4 TON.rup Calc=MJ8 Orientation=N Page I This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service CERTIFIEDT. between Feb 17, 2009 and Dec 31, 2013. Lwww.ahiidirectory.org -A) Certificate of Product Ratin2s AHRI Certified Reference Number: 5480779 Date: 5/8/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HNB648C**31 Indoor Unit Model Number: FE4AN(B,F)005+Ul Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: INFINITY 16 COASTAL HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 46000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 16.00 Heating Capacity(Btuh) @ 47 F: 46500 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 29400 Ratings followed by a_n asterisk(*)indicate a voluntary rerate of previously published data,unless arcompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, laims all liability for damages of any kind arising out ofthe use or performance of the product(s),or the the product(s)listed on this Certificate.AHRI expressly disc ry o unauthorized afteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirecto - rg. TERMS AND CONDITIONS HRI.This Certificate shall only be used for individual,personal and confidential reference purposes. This Certificate and its contents are proprietary products ofA re The contents of this Certificate may not,in whole or in part,be produced;copied;disseminated;entered into a computer database;or othervAse utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION verified at www.ahridirectory.org, A'_C nditioning,Heating, The inforrnation for the model cited on this certificate can be click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on imal n"d Roefrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. CERTIFICATE NO.: 130124940421706734 @2013 Air-Conditioning,Heating,and Refrigeration Institute