260 6th St 2013 HVAC BEACH CITY OF ATLANTIC 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002632 Date 5/08/13 Property Address . . . . . . 270 6TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------- -- -------------------------------------------------- Application desc 1 cu 1 ahu 2 . 5 tons ------------------------------- -- ----------------------------------------- Owner Contractor-------------- ---------- ------------------------ DONOVAN HEATING & AIR YEATS ALEXANDER 315 SIXTH AVENUE SOUTH 270 6TH ST FL 32250 ATLANTIC BEACH FL 322335318 JACKSONVILLE BEACH (9 04) 24 1-3 7 8 5 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc - - 95 . 00 Plan Check Fee . 00 Permit Fee . . . . Valuation . . . . 0 Issue Date . . . . Expiration Date . - 11/04/13 -------------------------------- --------------------------------------------CH DCA SURCHARGE 2 . 00 Other Fees . . . . . . . . . STATE ME STATE MECH DBPR SURCHARGE 2 . 00 ------- --------------------------------------------------------- - -------- Paid Credited Due Fee summary Charged ----- ---------- ----------------- ---------- -----95 . 00 . 00 . 00 Permit Fee Total 95 . 00 . 00 . 00 Plan Check Total . 00 00 other Fee Total 4 . 00 4 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Job: Project summary Date: May 3,2013 wrightsoft Entire House By: Aaron Thacker Donovan Heat & Air Phone:904-241-3785 Fax!904-241-3745 Email:aaron@donovanac1com Web www.DonovanAG,Gom 315 6th Ave S,Jacksonville Beach, FL 32250 - MMIM For-. Alex Yeats 270 6th St,Atlantic Beach, FL 32233 Notes: Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions 99 'F 39 'F outside db 75 'F Outside db 70 'F Inside db 24 'F Inside db 31 'F Design TD L Design TD Daily range 50 % Relative humidity 69 gr/lb Moisture difference Heating Summary Sensible Cooling Equipment Load Sizing 21470 Btuh 21368 Btuh Structure 7399 Btuh Structure 4158 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Blower Humidification 0 Btuh n Piping nt load 25527 Btuh Use manufacturer's data 1.04 Equipme Rate/swing multiplier Infiltration Equipment sensible load 30023 Btuh simplified Latent Cooling Equipment Load Sizing Method Average 2616 Btuh Construction quality 0 Structure 2094 Btuh Fireplaces Ducts 0 Btuh coolin Central vent (0 cfm) Heatin nt latent load 4710 Btuh Area (ft2) 1931 UP Equipme VolUrne(ft3) 15444 15444 Equipment total load 34734 Btuh Air changes/hour 0.38 0.20 Req. total capacity at 0.75 SHR 3.3 ton Equiv.AVF (cfm) 98 51 Cooling Equipment Summary Heating Equipment Summary Make Carrier PURON HP Make Carrier Trade BASE 15 Trade BASE 15 PURON HP Cond 25HBC542A 30 Model 25HBC542A**30 Coil FV4CN(B,F)005 AHRI ref no3646151 AHRI ref no3646151 Efficiency 13.0 EER, 15.5 SEER Efficiency 8.7 HSPF Sensible cooling 31500 Btuh Heating input 42000 Btuh @ 47'F Latent cooling 10500 Btuh 42000 Btuh Heating output. 27 'F Total cooling 1400 CfM Temperature rise 1400 cfm Actual air flow 0.048 cfm/Btuh Actual air flow 0.055 cfm/Btuh Air flow factor 0 in H20 Air flow factor 0 in H20 Static pressure 0.86 Static pressure Load sensible heat ratio Space thermostat Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2M-May-07 l3i35i56 Pagel + wrightSOft Right-Suite@ Universal 8.0.24 RSU05995 '1� C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3.5 ton-rup Calc=MJ8 Front Door faces: E -M—ECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: 0 <z,T PERMIT# PROJECTVALUE$ % 0c)_ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per.Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM REQULI?ED REPLACEMENT AIR CONDITIONING & BEATING SYSTEM INSTALLATION ARI# 3t,V�-/S,/ Air Conditionjing: Unit Quantity Tons Per Unit S,S REQUBtED Heat: Unit Quantity BTU'sPerUnit 17-cou Seer Rating.-�I 5—_5 � Duct Systems: Total CFM REQVZRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escal50—rs ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps Vented Wall Furnaces Refrigerator Condenser BTU's Water Heaters Solar Collection Systems Tanks(gallons) Wells :)THER: �ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six moaths-I herebY certify that I have read iis application and know the same to be true and corr=L All provisions of laws and ordinances governing this work will be complied with whether specified r not Ile permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction- roperty Owners Name Alr--x '/CAT-S Phone Number -7-?z 3z i /3 1-3 -IQ�OVO ii F41 fL -7f - -7� - fechanical Company Office Phone ��1-3 6S Fax -LH 1-3 -)y o.Address: 31,!�- e,-V,-, - cjty_�)a.!v- ik-&eAck StatefL- Zip 3,;Q-5b icense Holder Qhint): uJAU&VA Qui-,civar-i State Certification/Registration# i9tarized Sknature of License HoMer Sworn and subscribed before me this day of //41? 20 1 Signature of Notary Public NotarY Pubfic state of ROO �A Timothy Lee Hughes my commission EE 186278 44T/ Expires()4=12016 This combination qualifies for a Federal Energy "Imp Efficiency Tax Credit when placed in service A14M NEllki CERTIFIEDT11 between Feb 17, 2009 and Dec 31, 2013. www.ahiidirectory.org A Certificate of Product RatinaS AHRI Certified Reference Number: 3646151 Date: 5/8/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC542A**30 Indoor Unit Model Number: FV4CN(B,F)005 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditio,ning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 42000 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 15.50 Heating Capacity(Btuh) @ 47 F: 42000 Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F: 25800 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER resentationS,warranties or guarantees as to,and assumes no responsibility for, AHRI does not endorse the product(s)listed on this Certificate and makes no rep the product(s)listed oil this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS f AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. This Certificate and its contents are proprietary products 0 rwise utilized,in any The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or othe form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION at www.ahridirectory.org, Air Conditioning,Heating, The information for the model cited on this certificate can be verified click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on on 41 and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ATE NO.: 130124896927312056 @2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFIC