260 6th St 2013 HVAC BEACH
CITY OF ATLANTIC
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002632 Date 5/08/13
Property Address . . . . . . 270 6TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 -----------------------
-- --------------------------------------------------
Application desc
1 cu 1 ahu 2 . 5 tons -------------------------------
-- -----------------------------------------
Owner Contractor--------------
----------
------------------------ DONOVAN HEATING & AIR
YEATS ALEXANDER 315 SIXTH AVENUE SOUTH
270 6TH ST FL 32250
ATLANTIC BEACH FL 322335318 JACKSONVILLE BEACH
(9 04) 24 1-3 7 8 5
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc - - 95 . 00 Plan Check Fee . 00
Permit Fee . . . . Valuation . . . . 0
Issue Date . . . .
Expiration Date . - 11/04/13 --------------------------------
--------------------------------------------CH DCA SURCHARGE 2 . 00
Other Fees . . . . . . . . . STATE ME
STATE MECH DBPR SURCHARGE 2 . 00
------- ---------------------------------------------------------
- -------- Paid Credited Due
Fee summary Charged ----- ----------
----------------- ---------- -----95 . 00 . 00 . 00
Permit Fee Total 95 . 00 . 00 . 00
Plan Check Total . 00 00
other Fee Total 4 . 00 4 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
Job:
Project summary Date: May 3,2013
wrightsoft Entire House By: Aaron Thacker
Donovan Heat & Air
Phone:904-241-3785 Fax!904-241-3745 Email:aaron@donovanac1com Web www.DonovanAG,Gom
315 6th Ave S,Jacksonville Beach, FL 32250 -
MMIM
For-. Alex Yeats
270 6th St,Atlantic Beach, FL 32233
Notes:
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
99 'F
39 'F outside db 75 'F
Outside db 70 'F Inside db 24 'F
Inside db 31 'F Design TD L
Design TD Daily range 50 %
Relative humidity 69 gr/lb
Moisture difference
Heating Summary Sensible Cooling Equipment Load Sizing
21470 Btuh
21368 Btuh Structure 7399 Btuh
Structure 4158 Btuh Ducts 0 Btuh
Ducts 0 Btuh Central vent (0 cfm) 0 Btuh
Central vent (0 cfm) 0 Btuh Blower
Humidification 0 Btuh n
Piping nt load 25527 Btuh Use manufacturer's data 1.04
Equipme Rate/swing multiplier
Infiltration Equipment sensible load 30023 Btuh
simplified Latent Cooling Equipment Load Sizing
Method Average 2616 Btuh
Construction quality 0 Structure 2094 Btuh
Fireplaces Ducts 0 Btuh
coolin Central vent (0 cfm)
Heatin nt latent load 4710 Btuh
Area (ft2) 1931 UP Equipme
VolUrne(ft3) 15444 15444 Equipment total load 34734 Btuh
Air changes/hour 0.38 0.20 Req. total capacity at 0.75 SHR 3.3 ton
Equiv.AVF (cfm) 98 51 Cooling Equipment Summary
Heating Equipment Summary Make Carrier PURON HP
Make Carrier Trade BASE 15
Trade BASE 15 PURON HP Cond 25HBC542A 30
Model 25HBC542A**30 Coil FV4CN(B,F)005
AHRI ref no3646151 AHRI ref no3646151
Efficiency 13.0 EER, 15.5 SEER
Efficiency 8.7 HSPF Sensible cooling 31500 Btuh
Heating input 42000 Btuh @ 47'F Latent cooling 10500 Btuh
42000 Btuh
Heating output. 27 'F Total cooling 1400 CfM
Temperature rise 1400 cfm Actual air flow 0.048 cfm/Btuh
Actual air flow 0.055 cfm/Btuh Air flow factor 0 in H20
Air flow factor 0 in H20 Static pressure 0.86
Static pressure Load sensible heat ratio
Space thermostat
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2M-May-07 l3i35i56
Pagel
+ wrightSOft Right-Suite@ Universal 8.0.24 RSU05995
'1� C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3.5 ton-rup Calc=MJ8 Front Door faces: E
-M—ECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDRESS: 0 <z,T PERMIT#
PROJECTVALUE$ % 0c)_
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per.Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating—
Duct Systems: Total CFM REQULI?ED
REPLACEMENT AIR CONDITIONING & BEATING SYSTEM INSTALLATION
ARI# 3t,V�-/S,/
Air Conditionjing: Unit Quantity Tons Per Unit S,S REQUBtED
Heat: Unit Quantity BTU'sPerUnit 17-cou Seer Rating.-�I
5—_5 �
Duct Systems: Total CFM REQVZRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escal50—rs
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
Vented Wall Furnaces Refrigerator Condenser BTU's
Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
:)THER:
�ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six moaths-I herebY certify that I have read
iis application and know the same to be true and corr=L All provisions of laws and ordinances governing this work will be complied with whether specified
r not Ile permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction-
roperty Owners Name Alr--x '/CAT-S Phone Number -7-?z 3z i /3 1-3
-IQ�OVO ii F41 fL -7f - -7� -
fechanical Company Office Phone ��1-3 6S Fax -LH 1-3 -)y
o.Address: 31,!�- e,-V,-, - cjty_�)a.!v- ik-&eAck StatefL- Zip 3,;Q-5b
icense Holder Qhint): uJAU&VA Qui-,civar-i State Certification/Registration#
i9tarized Sknature of License HoMer
Sworn and subscribed before me this day of //41? 20 1
Signature of Notary Public
NotarY Pubfic state of ROO �A
Timothy Lee Hughes
my commission EE 186278
44T/ Expires()4=12016
This combination qualifies for a Federal Energy
"Imp Efficiency Tax Credit when placed in service
A14M NEllki CERTIFIEDT11 between Feb 17, 2009 and Dec 31, 2013.
www.ahiidirectory.org A
Certificate of Product RatinaS
AHRI Certified Reference Number: 3646151 Date: 5/8/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 25HBC542A**30
Indoor Unit Model Number: FV4CN(B,F)005
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: COMFORT 13 PURON HP
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditio,ning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 42000
EER Rating (Cooling): 13.00
SEER Rating (Cooling): 15.50
Heating Capacity(Btuh) @ 47 F: 42000
Region IV HSPF Rating (Heating): 8.50*
Heating Capacity(Btuh) @ 17 F: 25800
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER resentationS,warranties or guarantees as to,and assumes no responsibility for,
AHRI does not endorse the product(s)listed on this Certificate and makes no rep
the product(s)listed oil this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),orthe
unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org.
TERMS AND CONDITIONS f AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
This Certificate and its contents are proprietary products 0 rwise utilized,in any
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or othe
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION at www.ahridirectory.org, Air Conditioning,Heating,
The information for the model cited on this certificate can be verified
click on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on on 41 and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ATE NO.: 130124896927312056
@2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFIC