715 Redfin Dr 2013 HVAC CITY OF ATLANTIC BEACH
f 800 SEMINOLE ROAD
r�
"J ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002642 Date 5/13/13
Property Address . . . . . . 715 REDFIN DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU 2 . 5 TONS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BASS, JOHNNY HUXHAM HEATING & AIR
715 REDFIN DRIVE 2101 FLORIDA BLVD.
ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/09/13
-----------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
Boo Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845 13- 24�2-
JOB
ADDRESS: -76 PERMIT#.
ov
PROJECT VALUES 610c' p
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit SeeringREQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTTALLAT ON
Air Conditioning: Unit Quantity Tons Per Unit °�'S REQUIRED
Heat: Unit Quantity f BTU's Per Unit.3-0,W� Seer Rating_ 13
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION (quires 3 of plans)
Fire Sprinkler System qty (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires
3 sets of tans
Underground Fire Main Value (Requiresplans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty- Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
within a six month pe[iod or wrack is or abandoned for six months_I heaeby cert*that I have read
Permit becomes void if work does not comms of laws and or�emces govemiog this will be com4)plied with whether specified
this application and know the same to be true and correct- All provisions a the hed�ce of construction
or not. The permit does not give mftritY to violate the p[ummns of any other store or bail iawregnlabon
constraction Property Owners Name FESS Phone Number
/ �� 1,�1 ,, �, t` Office Phone•� Fax y! 03 77
Mechanical Company..�,c., �T,^,,,,., ��,�--
City state P-zip
Co. Address:
93 ll ��� �
State Certification/Registration
License Holder(Print):
Notarized Signature ofLicense H 2(V
3
�.,,,,,,,,,,. �ostt - o and subscribed before thi _day of
'. �,try�
Comm.Exolres�Oct 21,tot tore ofNotary Public
���, CommNOW*EE 045406
Job: 51013
RODRIGUEZ Project Summary Date: May 10,2013
energy consulting
Entire House By: ERIN RODRIGUEZ
Proiect Information
For: BASS
715 REDFIN DRIVE,ATLANTIC BEACH, FL 32233
Notes: HUXHAM -CHANGE OUT
Desian Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 92 °F
Inside db 68 °F Inside db 76 °F
Design TD 29 °F Design TD 16 °F
Daily range L o
Relative humidity 50 /o
Moisture difference 56 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16526 Btuh Structure 14662 Btuh
Ducts 3591 Btuh Ducts 5019 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 20117 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 19090 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Constructionq ualit Tight
558 Btuh
Fireplaces y 0 Structure 1315 Btuh
Ducts
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft2)
1570 1570 Equipment latent load 1873 Btuh
Volume (ft') 12557 12557 Equipment total load 20963 Btuh
Air changes/hour 0.14 0.07
Equiv.AVF (cfm) 29 15 Req. total capacity at 0.70 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make
Trade Trade
Model Cond
AHRI ref Coil
AHRI ref 0 SEER
Efficiency 80AFUE Efficiency 0 Btuh
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 °F Total cooling 787 cfm
Actual air flow 787 cfm Actual air flow 0.040 cfm/Btuh
Air flow factor 0.039 cfm/Btuh Air flow factor 0 in H2O
Static pressure 0 in H2O Static pressure 0.91
Space thermostat Load sensible heat ratio
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2013-May-1011:37:23
+ wrightsoft Right-Suite®universal 2012 12.1.07 RSU01508 Pagel
,411! . ...ents\WrightsoftHVAC\Template\HUXHAM-BASS.rup Calc=MJ8 FrontDoorfaces:N