Loading...
715 Redfin Dr 2013 HVAC CITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD r� "J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002642 Date 5/13/13 Property Address . . . . . . 715 REDFIN DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 . 5 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BASS, JOHNNY HUXHAM HEATING & AIR 715 REDFIN DRIVE 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 246-6721 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/09/13 ----------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH Boo Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 13- 24�2- JOB ADDRESS: -76 PERMIT#. ov PROJECT VALUES 610c' p NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit SeeringREQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTTALLAT ON Air Conditioning: Unit Quantity Tons Per Unit °�'S REQUIRED Heat: Unit Quantity f BTU's Per Unit.3-0,W� Seer Rating_ 13 Duct Systems: Total CFM REQUIRED FIRE PREVENTION (quires 3 of plans) Fire Sprinkler System qty (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of tans Underground Fire Main Value (Requiresplans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty- Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: within a six month pe[iod or wrack is or abandoned for six months_I heaeby cert*that I have read Permit becomes void if work does not comms of laws and or�emces govemiog this will be com4)plied with whether specified this application and know the same to be true and correct- All provisions a the hed�ce of construction or not. The permit does not give mftritY to violate the p[ummns of any other store or bail iawregnlabon constraction Property Owners Name FESS Phone Number / �� 1,�1 ,, �, t` Office Phone•� Fax y! 03 77 Mechanical Company..�,c., �T,^,,,,., ��,�-- City state P-zip Co. Address: 93 ll ��� � State Certification/Registration License Holder(Print): Notarized Signature ofLicense H 2(V 3 �.,,,,,,,,,,. �ostt - o and subscribed before thi _day of '. �,try� Comm.Exolres�Oct 21,tot tore ofNotary Public ���, CommNOW*EE 045406 Job: 51013 RODRIGUEZ Project Summary Date: May 10,2013 energy consulting Entire House By: ERIN RODRIGUEZ Proiect Information For: BASS 715 REDFIN DRIVE,ATLANTIC BEACH, FL 32233 Notes: HUXHAM -CHANGE OUT Desian Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 76 °F Design TD 29 °F Design TD 16 °F Daily range L o Relative humidity 50 /o Moisture difference 56 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 16526 Btuh Structure 14662 Btuh Ducts 3591 Btuh Ducts 5019 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20117 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 19090 Btuh Method Simplified Latent Cooling Equipment Load Sizing Constructionq ualit Tight 558 Btuh Fireplaces y 0 Structure 1315 Btuh Ducts Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1570 1570 Equipment latent load 1873 Btuh Volume (ft') 12557 12557 Equipment total load 20963 Btuh Air changes/hour 0.14 0.07 Equiv.AVF (cfm) 29 15 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref 0 SEER Efficiency 80AFUE Efficiency 0 Btuh Heating input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 787 cfm Actual air flow 787 cfm Actual air flow 0.040 cfm/Btuh Air flow factor 0.039 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure 0.91 Space thermostat Load sensible heat ratio Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2013-May-1011:37:23 + wrightsoft Right-Suite®universal 2012 12.1.07 RSU01508 Pagel ,411! . ...ents\WrightsoftHVAC\Template\HUXHAM-BASS.rup Calc=MJ8 FrontDoorfaces:N