18 17th St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD -rj ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ills) Application Number . . . . . 13-00002665 Date 5/15/13 Property Address . . . . . . 18 17TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 4999 ---------------------------------------------------------------------------- Application desc 4 TONS 8K BTU' S ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ RICHARDS JOHN & LYNN M LEGGETT HEATING & AIR 18 17TH ST 660 KING STREET ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32204 (904) 384-2612 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/11/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. A Ulm IOU anal CERTIFIEDTM L www.ahridirectory.org_j Certificate of Product Ratings AHRI Certified Reference Number: 5720565 Date: 5/15/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdonr Uni! Model Indoor Unit Model Number: GAM2AOC48S41+TDR Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210!240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 46500 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F 46000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 30800 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRf does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the prod uct(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized a Iteration of data listed on this Certificate.Cenified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRL This Certificate shall only be used for individual,personal and confidential reference purposes. The contents ofthis Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;orotherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited or,th]s cettificate can be vc-Kned at vwh%atjridirectory.org, A "IMF, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above-ard th�Certificate No.,Ithlich is listed below. how On S1 and Ref rigeration Institute @2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130130964953472258 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: +IWL9 0 L�, -,�aa�6 PERMIT# PROJECT VALUE $ L/99 9 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating J� Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION A R I# 5-) -z (9 fto Air Conditioning: Unit Quantity I Tons Per Unit 14 REQUIRED Heat: Unit Quantity i BTU's Per Unit F4 Seer Rating / -7) Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name :22L4 + 21 Phone Number 1.5 Mechanical Company Loqqe, -� g�t T4— Office Phone, Co. Address: (2� Ki'" city Statd,�L Zip 3a, License Holder(Print): B41V Co . 0 j/1) n4r State Certification/Registration#Cfh(-O 59 67 Notarized Signature of License Ho r Sworn and subscribed before me this d 20L KATHERINE L PHLUPS MY COMMSSM 0 EE155163 Signature of Notary Public (k) EXPMS Dowrdw 21,2015 Inc. I Job: Leggett Heating&Air Project Summary Date: May 14,2013 Entire House By: Leggett Heating & Air Inc, 660 King St.,Jacksonville,FL.32204 Phone:904-384-2612 Fax:904-384-4893 Email:Billy_leggeftheatingandair@comcast.net Proiect Information For: Richards 18 17th Street, Atlantic Beach, FL 32223 Notes: Design Information Weather: Jacksonville, Cecil Field NAS, FL, US Winter Design Conditions Summer Design Conditions Outside db 34 'F Outside db 95 'F Inside db 68 'F Inside db 75 'F Design TD 34 'F Design TD 20 'F Daily range M Relative humidity 50 % Moisture difference 40 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32395 Btuh Structure 31757 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32395 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 31757 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2978 Btuh Ducts 0 Btuh Heating Coolin Central vent(0 cfm) 0 Btuh Area (ft') 1461 1469 Equipment latent load 2978 Btuh Volume (ft3) 13149 13149 Air changes/hour 0.54 0.23 Equipment total load 34734 Btuh Equiv. AVF (cfm) 119 50 Req. total capacity at 0.70 SHR 3.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 HSPF Efficiency 0 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47oF Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1448 cfrn Actual air flow 1448 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-May-14 12:01:54 wrightsoft Right-Suite(D Universal 2012 12.0.10 RSU09454 Pagel ...Billy WarlitnerkMy Documents\Wrightsoft HVAC\hchards5l4l3.rup Calc=MJ8 FrontDoorfaces