Loading...
331 N Oceanwalk Dr 2013 HVAC CITY OF ATLANTIC BEACH s) 800 SEMINOLE ROAD -r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002722 Date 5/23/13 Property Address . . . . . . 331 N OCEANWALK DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------ Application desc 1 cu 1 ahu 2 tons ------------------------------------------ Owner Contractor ------------------------ TOMAMICHEL SNYDER HEATING & AIR 331 OCEANWALK DRIVE P.O. BOX 16826 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32245 (904) 641-0600 ----------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 91 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/19/13 _ ----------------------------- Other Fees . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due _ _ ---------- --- ----- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITU OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax(904)247-5845 JOB ADDRESS: PERmrr# PROJECT VALUE $ -501Z °O NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity _ BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTAI.I,ATION ARI# 5 3316�Z-} Air Conditioning: Unit Quantity k Tons Per Unit Z- REQUIRED Heat: Unit Quantity I BTU's Per Unit ?,-l000 Seer Rating %S Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 3 4-:' Phone Number GtoS-2S7 Z Mechanical Company S�.,d r C-o • Office Phone lost l-ot000 Fax Co. Address: 1USl o City State C-,.- Zip 2T License Holder(Print): Cas,-i^ 1A. rA+tl S to cation/Registration# C ACt`6l3',02 Notarized Signature of License Holder Sworn and subscribed before me this day of 2013 HOLLY A FOUST �\ c* MY COMMISSION#EE 204856 Signature of Notary Public v` EXPIRES:July 21,2016 I'�rFOF F� , Bonded Thru Budget Notwy Services This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service NOU Was 1 between Feb 17, 2009 and Dec 31, 2013. CERTIFIEr r r Certificate of Product Ratings AHRI Certified Reference Number: 5338827 Date: 5/23/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR5024G1 Indoor Unit Model Number: GAF2AOA36M31+TDR Manufacturer: TRANE Trade/Brand name: XR15 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 24000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh)@ 47 F: 22000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 13000 Ratinas followed by an asterisk(')indicate a voluntary rerate of previously published data.unless accompanied with a WAS.which indicates an involuntary rerate- DISCLAIMER AHRI does not endorse the products)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ��' The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. On -' and Refrigeration Institute which the certificate was issued.which is listed above,and the Certificate No.,which is listed below. 'D2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130137913528219538 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems F",Np, customer • • Street Address 331 oceanwalk dr, Atlantic Beach, FL 32233 ..................... .......................................... ....................... Latitude, Longitude 30.33750, -81.76860 ................ ...................... . ......_................................__._...._.................._._........_..........._.................._._....__._........._... House Square Footage: 950 sq. ft. _ ..................................................................._..............._......_._..............._....__._..................._......_._........................_....._....._....._........... Name: jell tomamicheal _.__.._...................................................._........................................_......................................................... .. Phone: 123-123-1234 ......................................................................._..............._................................................_.._..........._...............__....................................._........................................................_.................. Email: example@mail.com House • . • SHR .75 ................................................................................._....................._..................................................................._._........................................................................................ Number of residents 2 ............... ....... ..................................._.........................................................................................._................................................................__._................................................_.................................... Ceiling height 9 ......................... .... ......... Wall U-value R-value 0.09111 .................... ............................................................. ............_........................................_..................................................... .._ .................................... . Floor U-value R-value 0.2 1 5 ............................... ......_.........................................................................._._.............._................................... ....._.____ - Ceiling U-value R-value 0.053 19 ........................................._ Window U-value 0.5 --...........- ....................... ....................................................................................._..................................................._................._..............................................._................................ Window SHGF 0.85 ................................................ .............. ......................................................................................................_............................................................._........._........... .._.......... ................._.......... Moisture grains 53 ........................................... . ............................ .................... . . Duct loss % 10 . ............................ ........................... ...................................... ........................................... .................... ...................... Duct gain % 10 ...................... ..................... ...................... ............... Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 ............................................._....................................................................................................................._....................._.__....__ 11 Summer ventilation 0 Design Conditions OutdoorHeating Cooling ..........................._.................................__ ............................ ................... Dry bulb (°F) 32 93 ............. Daily range M ............................................................................................................._......_......................................._.............................. Relative humidity 50% ................................................ ........................................ ....................... ... ........ . _ ...... _ .__... ....__ Moisture difference 53 ................................................................................................................................_ ...__ ..... __....._. .......__..................._.._............._............_ IndoorHeating Cooling ................... ................................................ . ...................... Indoor temperature (°F) 70 . ............................. .................._...__............... ........................... Design temperature differenceff) 38 18 .......................................................................................................................................................................................__...................._......................__ . .._ • • • Area Btuh % of loa . Wall 3326 12.1 ............................... Floor 12753 46.3 Ceiling 1913 6.9 Windows 2603 9.5 ..................... Infiltration 4432 16.1 ................_...................._............................................................ ._..__.....__ System Efficiency Loss 2503 9.1 ............................................................... ................................._................................._.........................................._ Total: 27530 ..................................._................................._......_............_..._..........................._....................._. Heating Loads 27,530 BTU/hr Ceiling System Efficiency Loss Windows Floor Wall Infiltration MO �", ?'�Y'$h°.�. 4., X'r 4?aa,�Rt'n} 1� �knk4,�r ", }�:,'f'txfi„1•r 0 O olinq Loads Area Btuh % of load Wall 24Di Ceiling 2669 12.5 Windows 7603 35.5 Sensible Infiltration 1574 7.4 Latent Infiltration 2866 13.4 ......_..... . . . ....... .. ... . ......... System Efficiency Gain 1716 8 ................... ............................................... . ...................... .. Internal 1615 7.5 ............................................ .................... ....... ........ ........ Sensible People Load 460 2.1 Latent People Load 460 2.1 .............................. . Total: 21414 ..................... ......_.......................... Sensible load 18088 . ......................... .... ....................... Latent load 3326 ................. . ........................................ ................................ SHR 0.84 ........._.........._......... ............................ ....................._- Capacity at .75 SHR 2.01 Tons ..................... .... .................................. Cooling Loads 21,414 BTU/hr r Sensible People Load I ! atent People Load -,"sibie Infiltration Internal Windows System Efficiency ,AA �-Wall Latent Infiltration / `ceiling 'Adequate Exposure AED Graph 10000 7500 a M 5000 J 2500 8am gam 10am 11am 12pm 1pm 2pm 3pm 4pm Spm 6pm 7pm 8pm Hourly Loads —Average 'Equipment ' • System equipment selection will be made using the following derived values. Glass (E) 69 sq. ft. _...........__.._......................-.................................................................._............-................................_...._..._._............._ ____ -................................................................................... Glass (S) 10 sq. ft. .................................-.........._............................_............_..............._............._......................._........................._......_.__ .........-................................. Glass (N) 10 sq. ft. ................................................................................................................................................_................................ ............ .. ._.. .... ---...................................................................................... Glass (W) 48 sq. ft. ..................................................................................................................................................................................................._.............................................--........................................................... . Summer Outdoor 93°F Summer Wet Bulb 77°F .................. _.............. _ _.............................................................................................................................._........................................................................................... Summer Indoor 75°F .............-............... Summer Design Grains 50% Winter Outdoor 320F ..................................._......................................... .........._..................._...................................................._....................................................._.............................._ Winter Indoor 70OF ............ ........................................................................................................................................................................................................_....._._................._.........._...................................._.................. Sensible Cooling 18,088 Btuh ......................................... ...... ....... ........._.._.. .................................................................................... Latent Cooling 3,326 Btuh ................................._. ......_....... ........_................_... _ . Required Cooling Airflow 822 CFM ...................._..._ Sensible Heating 27,530 Btuh ..........................................._................. .. ... Required Heating Airflow 358 CFM ......... .. . . ..... . ... ......... .. .. ...... . . . ..... All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree