Loading...
350 6th St 2013 Pool " ':► CITY OF ATLANTIC BEACH s) 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �rJf31�'' Application Number . . . . . 13-00002691 Date 5/29/13 Property Address . . . . . . 350 6TH ST Application type description SWIMMING POOL/SPA Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 20000 ---------------------------------------------------------------------------- Application desc NEW POOL ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GEORGI, KIROVALL STRONG, INC 307 BRAYDEN WAY 50 AUDUBON LANE LAYTON UT 84041 FLAGLER BEACH FL 32136 (904) 347-6108 ---------------------------------------------------------------------------- Permit . . . . . . SWIMMING POOL Additional desc . . Permit Fee . . . . 150 . 00 Plan Check Fee 75 . 00 Issue Date . . . . Valuation . . . . 20000 Expiration Date . . 11/25/13 ---------------------------------------------------------------------------- Special Notes and Comments POOL - Wellpoint (if used) must discharge into vegetated area 10 ' minimum from street or drainage feature (swale, structure or lagoon) . Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. Keep roadway cleaned at all times . 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE REQUIRED INSPECTIONS : *POOL STEEL *ELECTRICAL GROUNDING AND BONDING *FINAL (PUMPS MUST BE RUNNING FOR FINAL) SWIMMING POOL SAFETY INSPECTION REQUIRED POOL SHALL BE NO CLOSER THAN 5 ' FROM REAR OR SIDE PROPERTY LINES . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE DCA SURCHARGE 2 . 25 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITIDWAiiEV-i E4FR(INGIIBWNA-kC)3;-r I'HE FLO{I9A 0 0 BUILDING CODES. CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ±� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Page 2 Application Number . . . . . 13-00002691 Date 5/29/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE DBPR SURCHARGE 2 . 25 UTIL REV PRE APP >3 HRS 25 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 150 . 00 150 . 00 . 00 . 00 Plan Check Total 75 . 00 75 . 00 . 00 . 00 Other Fee Total 79 . 50 79 . 50 . 00 . 00 Grand Total 304 . 50 304 . 50 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ' BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH a M 800 Seminole Road, Atlantic Beach, FL 32233 U Office (904) 247-5826 Fax (904) 247-5845 Mq 2 0'201..? Y Job Address: Permit Nu Legal DescriptionIo / 7 "- arce a `1 # Valuation of Work$ QC) Floor Area oq. t. Sq.Ft Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolitir/ji Use of existing/proposed structures) (circle one): Commercial Zg�o If an existing structure,is a fire sprinkler system installed? (Circle one):Florida Product Approval # > For multiple products use product approval form Describe in detail the type of work to be performed: 1,4,'s, ovAll Property Owner Information: / �// Name: e >� Address: 35 y G�4 St f/��� G a"( J7 City StatZip 3�133 Phone ItE-Mail # (Optional) Contractor Information: Company Name: e Qualifying Agent: -IA.*" Address:SU City State _Zip Pz U Office Phone Job Site/Contact Number Ar Fax# State Certification/Registration# GPG 03Sr60 Architect Name&Phone# Engineer's Name&Phone#IPA A&A_ Pi+a Y- 391 �?7 489/ Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. 1 certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes mill and void if work is not commenced within six(6)months, or if construction or work is suspended or abandoned for a period of stx6)months at any time after work is commenced. I understand that separate permits must be secured for forWork,Plumbing,Signs, Wells,Pools, urnaces,Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereb certify that 1 have read and exams ed this a plication and know the same to be true and correct. All provisions of laws and ordinances governing this type oVlwork will be complied with wheth r spec ted herein or not. The granting of a permit does not presume to give alit r' to violate or cancel the provisions of any other federal,st te, or loc I law gulating construction or the performance of construction. Signature of Owner Signature of Contractor C Print Name C �i V Print Name `/..4:.. ,,,e....r........ .. --............................................................. .............................................. ............................................................................. Before, , Before lv� this ;r9ay of a !f 20t 3 this 16, Day of 20 ; • PATRICIAAtXE Nota Public .� •.,, Notary Public ,ti + tS �� r` C. PATRICIA WAL E MY COMMISSION#DD 894636 i,; .: MY COMMI I !� y'• ` EXPIRES:September 4,2013 s:�:4 EXPIRES: S t� 32 2 Bonded ThN Notary Public Underwriters '�pf ihq�` Bonded Th.Notary public Underwriters 800 Seminole Road Atlantic Beach, Florida 32233 Telephone(904)247-5800 FAX(904)247-5805 :t+ r Construction Site Management Plan Compliance A construction site management plan conforming to Atlantic Beach City Code Sec 6-18 has been approved as a part of this building permit. The Construction site management plan was approved based upon the following information. 1. Parking plan—parking plan showing how site will be accessed and all onsite and abutting street parking areas. 2. 3. Location of construction trailers, loading/unloading area and material storage area. 4. Location of chemical toilet area.(chemical toilets must be kept out of City right-of-way and not further than 15 feet from structure under construction) 5. Location of dumpster. Dumpster must be from an approved waste company (in accordance with Chapter 16 City Code) as of 2009 the permitted dumpsters are Advanced Disposal, Realco Recycling, and Shappells. Dumpsters will have tarp covers or rigid covers on windy days. Dumpsters must be removed prior to issuance of Certificate of Occupancy. 6. Traffic control plan, showing access with dimensions, area to be stabilized, narrative on phasing of construction with adequate parking and delivery of materials. 7. Site cleanliness. Contractor must have the entire construction site cleaned by Friday of each week. This means removal of scrap lumber, concrete remnants and other such construction debris including cans, metal, plastic and paper. 8. Erosion and Sediment Control. Contractor must maintain all elements of the approved Erosion & Sediment Control Plan (silt fence, catch basin filters, etc.) until sod or other stabilization has been placed and approved by Public Works. 9. Other activities, where special conditions are identified by the Building Official. Failure to comply with the Construction Site Management Ordinance may result in a Stop Work Order being issued in accordance with City Code Sec. 6-17 (3) Revised 5/2009 Doc # 2013126923, OR BK 16375 Page 1335, Number Pages: 1 , Recorded 05/20/2013 at 11 :06 AM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING $10.00 -BLE Copy ; NOTICE OF COMMENCEMENT' E (PREPARE IN DUPLICATE) Permit No._ /✓ 6 !� Tax Folio No. State of County of To whom N may concern: The undersigned hereby Informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal des ptlon of ro rty bein Improved:L 'fes C Address of property being Improved: O L i Gene`rAl desuuipllon of improvements: A _ OC Owner Address Owners Interest In site of the improvement Fee Simple Titleholder Of other than owner) Name Address Contractor Address Phare No.3S?17 Q Fax No. tasty Of any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the Improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other i documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to recetve a copy of"Lienors Notice as provided In Sectlon 713.08(2)(b),Florida Statutes.(Fill in at Owner's option). Name a. Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date Is ne(1) ar from the date of recording unless a different date Is specMed): g. THIS SPACE FOR RECORDER'S USE ONLYt OWNER c / / r Signed: ATE u /1 ��'13 Before me thls day of o In the Couply of Duval,4atept�Iodda,h7 pe ally appeared O.^4 i CT i r• r/ hereh by - himself/ hersoff and affirms that all etare aro sUc and accurate PATRICIA WAVE M Y.. : MY COMMISSION 4 DD 894636 _ g EXPIRES:September 4,2013 Bonded Thru N012ry Public Underwriters Notary Public at Large,State of L Countyof My commission expaes: Personally Known ❑r Produced[denllficatlon elroL/ EJ iEl o m D ❑ ❑ ❑ ❑ [ I ❑ ❑ ❑ ID C � 9 A S• l7 � �.y'N Tom-, (D 7'm N 'd do T�% Oc09 3��cnov� 3o 01PQ, 0 o mmma� p d o Q N CL QQ °= —In 9 m Q CD CD 7.p N 0 D 0 3 Cl N C1 O Cp y FILE COPY 3' _ 'o - 0 —:0p �.- , CD nm O SCD 65 ~ p � 7 N N QN N n N(D Swimming Pool Energy Efficiency Compliance Information NOTE: These Requirements Apply ONLY to the Filtration Pump ANSI/EPSP/ICC-15 2011 Flow Calculations Pool water volume I y7G-P-►360= y 'gpm-this is the calculated flow rate. Note: for pools under 13,000 gals.The calculated flow rate or 36 gpm whichever is greater=the filtration flow rate If there is an Auxiliary load on the filtration pump? Yes .__ __ No ✓_ If so,what is the calculated auxiliary flow rate h --gpm Flow Rate(low speed) __ gpm ct, Minimum suction side pipe size @ 6 fps 1 in. Minimum suction side branch pipe size @ 6 fps Z _in. Minimum suction side pipe size @ 6 fps Z in. Minimum suction side branch pipe size @ 6 fps?– _in. Determine Filter Size: Filier factors(GPM/SF) Cartridge(0.375) DE(2.0) Sand(15) filter Size: - –/ --- __ ar (Flow Rate) (Filter Fact) Filter Size (Filter Make and Model) Pump Controls Filtration pump has no auxiliary load–standard time clock_ Filtration pump with auxiliary load–Control model for low speed default within 24 hr. Healer Model Gas Heater efficiency rating --- (No Pilot Light) I feat Pump efficiency C.O.P. ANSI 5 & ANSA 7 Compliance Work Sheet Determine Simplified TDH: I. Distance from pool to pump in feet fiction loss(in suction pipe)in �__inch pipe per 1 ft.@ a Zgpm=•_,r / (from pipe flow/friction loss chart) Jww � - 3. Fiction loss(in sQotim pipe)in /Z inch pipe per 1 ft.@ 2- gpin `�z_(from pipe flow/friction loss chart) TDH in Piping Determine Simplified TDH: — Filter/Heater loss in TDH z' �' 1 4. _ -- ---------- t i..ngm ol�Suca.Pipe) (Ft of head/t n.of pipe) (TDI-I Suct.Pipc) - g• Z All other losses _.._ --------_-. x . 12- 1 -_ (Length of Return Pipe) (Ft of head/1 ft.of Pipe) (TDH Suct.Pipe) Total Dynamic Head(TDH): ___----- Determine Pipe Sizes: / Branch Piping to be 2" inch to keep velocity @ G 6 fps max.at 2- gpm System Flow Rate. Trunk,Skimmer& Suction Piping to be 2 inch to keep velocity(cry fps max.at 9 2 gpm System Flow Rate. Return Piping to be w inch to keep velocity @ _. /s9 fps max.at �gpm System Flow Rate Pump Selection as Listed on Curve A or C(circle one) 1'11tralion pump �3R �.r. �`c�:r bP Maximum Flow Rate m -- ---—-- -- --- Y_ Main Drain Cover �-'' ' S►' _ (Make and Model) Determine the Number and'rype of Required In-Floor Suction Outlets: Check all that apply. 1 3'-0" Qo 2 suction outlets(a0 gpm max. flow f 2s 3 suction outlets @, gpm max. flow - channel drain @ gpm w/ _ ports Flow and Friction Loss Per Foot Schedule 40 PVC Pipe Velocity - Feet Per Second _Pipe_ Size 6 fps 8 fps 10 fps 1,, 16m 0.14' 21 gprn 0.23' 28 gpm 0. ' 37 gpm 0.08' 50 gpm -0:14' 62 gpm 21' 2" 62 gpm 0.06' 82 gpm( 0.10' 103 gpni 0.16' 2.5" 88 gpm 0.05' 117 r m 0.09' 146 gpm 0.13' 136 0.04' 181 gpm 0.07' 227 gpm 0.10' _ 9pm 4„ - -- 234 0.03' 313 gpm 0.05' 392 gpm 0.07' m 6V 534 0.02' 712 gpm 0.03' T 111 F— J T_DI I Calculation Options 7- h 3 WNFR For each pump — >�i r o v Check one. _)a:m Signature QZSimplified"Total Dvnamic Head(STDH) Complete STDH Worksheet-Fill in all blanks CPG •. 3SG4fv 13 Total Dynamic Head(TDH) Contractor Cert.No. Complete Program or other calcs. Fill in required blanks on worksheet&attach calculations. G S Z 7 , 7 g ✓ 0 Maximum Flow Capacity Contractor Telephone No. Scale: None Of the new or replacement pump. The Association of Pool&Spa Professionals," ANSVAPSP/ICC.l5 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS I'RO1F(T NAME: _ CONTRACTOR NAME �J AND ADDRI.SS �1+ro V"4 i ► '' r AND AUt3kE:S5: `I•AMES EDEN JI iwNl It. I4 CONTRACTOR PHONE: DATE: IL. i 1 hi•.information sheet was prepared by the APSP-15 Residential Swimming Pool and Spa Energy Efficiency Standard Writing Committee of the Association of Pool and Sp:i Prolv%sionals(AP-1,P). It is not part of the American National Standard ANSI/APSP/ICC-1.5 2011 but is included for information only.Contractors should acquire and comply with the ANSI/AP-,P/ICC--15 2011 standard which can be purchased at www.apsp.org. �t. §5.2.1:Calculated pool volume �. C,allnns: 16 fi00 ' ;or I. Y.7¢a gallons h.calrulated Gallons: __(surface area)X __ (average depth)X 7.48 (gal/ft"3) = 0 '-§5.2.1:Calculated maximum filtration flow rate 2. gpm (1'uul volume: 160 or 36gpm whichever is larger) '.§5.2.2:Auxiliary Fool Load: _UYes, ( No? i (l nirr the highest'auxiliary pool load"to be powered by the swimming pool filtration pump.Do not add auxiliary 3• gpm i pnnl/Wld flow rates together,only the highest is used.) 4. Calculated maximum flow rate 4.— gpm i'llvir7 2 or item 3, whichever is larger.) - §5.5.�,:Pipe sizing: a.Minimum suction pipe diameter 5a._ 2.0 inches (Enter the smallest pipe size from Table 1 with a 6 fps flow rapacity the same or more than item 4.) b. Minimum suction branch pipe diameter 5b. 2.0 inches (Calculate:item 4. _ 47—(-qpm).,Branch Pipes 1 (quantity)=branch flnw rate 47 (gpm). Enter the smallest pipe size from Tnblr 1 with a 6 fps flow capacity the same or more than the calculated ,uctinn branrh.fiow rate.) c. Minimum return pipe diameter Sc. 1 , inches (Enter the smallest pipe size from Table 1 with a 8 fps flow caparity the some or mare than kem 4.) d.Minimum return branch pipe diameter Sd. 1.5 inches (Cnkulote:Item 4. ._ 4?_(qpm);Branch Pipes__? (quartity)=branch Onw rate 47 (gpm). Enter the smallest pipe size from Table 1 with a 8,fps flnw r0pacity the some or more than the calculated i eturn branch flow rate.) 65.4.1: Filter type and size: o. Filter type:(Cartridge, DE,Sand) 6a Cartridge b. Minimum filter-irea (Calculate:item 4._Y/ (gpm)_filter factor 0.375 ) 6b. I v 9. 13 sq.ft. l ilter factors:Cart 'd a=0.375 Sand=25,Diatomaceous Earth-2 1. 45.4.2:Backwash valve: ffYes,Jallo? (Whi•n using n backwash valve,enter result of item Sc or 2 inches whichever is larger) 2.0 inches — Table 1 Plpp$Mdii "1.5" ` -*^ Zvr , 3" 3.6" _7;F7 + Nominal GPM @ 6 fps 3A F3 90 13ii 1t; 23II 3114 I .,40 Nominal GPM 2 a fps 51 II4 119 194 247 317 499 720 `:.Dump selection: h.'..:;.2..t:Enols 17,000gallons or fess,select pump from the database with a Curve-A gpm flow equal to item 2 or less. 1`0011, 17,001 gallons or more,select pump•from the database with a Curve-C gpm flow equal to item 2 or less. "M111ti- ••P'1d pumps must have one speed listed that satisfies this requirement. a.Pump model ga. SFN / — A b. Pump flow 8b. 31 gpm (.0.3.2.1,53.2.2:Applicable Curve A or C gpm flow listed in database) 4/4/17 ANSI/APSP/ICC-15 Standard Writing Committee Form ni ANSI/APSP/ICC 15 ENERGY EFFICIENCY COMPLIANCE INFORMATION FOR RESIDENTIAL SWIMMING POOLS (nmpnnen[ Section Requirements Check 4.4.1.1 Heater has no pilot light r L_J r 4.4.1.2 Readily accessible on-off switch mounted outside of the heater (� I: L___I Heaters 4.3.1.3 No electric resistance heating unless for inground spa with tight fitting cover with R-6 insulation, (� or for pool with 60%of documented pool heating from on-site solar or recovered energy. C� 'i _ 4.3.2 Heater efficiency:gas/oil fired heater efficiency at least 78%,heat pump COP at least 4.0 5.1.1 Pool filter pump listed in database iFvolr r 5.3.3. Pool filter pump with total horsepower 1.0 or more is multi-speed r L_� Multi-speed pump controller programmed to default to the filtration flow rate when no auxiliary 5.3.3 pool loads are operating within. 24 hours and programmed with temporary override capability for L servicing, L . fl :'cfnl systems 5,3,4 Single-speed pump controller capable of operating ❑ p p g pump during off-peak electric demand. �+ 5.5.2 Pipe before pump has at least 4 diameters of P straight pipe. g System installed with solar,or setup for the future addition of solar heating equipment by 5.5.3 installing 18 inches of horizontal or vertical pipe after the filter and before a heater,or built-in or !i built-up connections,or dedicated pipe to and from the pool. 5.5.6 Directional inlets for mixing pool water. Swimming Pool Energy Efficiency Compliance Information NOTE: These Requirements Apply ONLY to the Filtration Pump . remazr staler Pool and SPa»Pool p,:os>,­ Prc>d7atr,s:' P><unps»inground» SuperFl... Page l of For Pool Prcir; 1 l - English E:sp;l}or w ��� - Products Pentair Partners Dealer ResourceEEARGH s Nlaauahl Brrort,nr.•,>. 1 ;2fety/Warnings Eco Select Imag" plow ,tenlo pod p,us>s•FYUWR2a>s ">InarouMl>r Supr rFlO'0 PumPst Products Cliff 011(+(to bxpaatt lief (`lick or H to collansta tilt uper� v) Aogr*, ttd SyAlettle[j.1 Pumps Automation(+J Efficient, cmiet, rugger!and versatile Clf`arllrs(+J . (;omrom tial TIl®SuperFloe Puntpe pumps are specifically designed to be the best choice for a variety of inground llp_ Pool"-SuperFlo features thick walled body pans,a heavy-duty engineered hydraulics.Su "I' tY 56 square flange motor,and highly uikerA(+J perFlo's sflaM mm�lnp capability and small footprint allow It to easily drop into a compact equipment pad, Healers&Ploal Pumpa(+) U.9hling I+) �F'•`9XUt'C:S fiAauttenenco 8 Sefgty uperl 10 by Pentair Pool ProduCbe is a direct replacement for lhn HaHayward"Super punpGDn I-qupment j+( Fxlramely quiet operation PIntIP•`r-( t tr;ionizad fknngs 0'i In,intemni slip and 2 in.oxturnar slip) xtground(-I CAM and Ramp"I.irl ^hark..W High Flow Pumps Heavy-duty,high Gervino factor 58 square flange motor Chenenger lirfth Prrt sure (ntegml"01(40 and pot raa'uca hydraulic noise Rai+oc Protected by(1.5.Patant D517,570 G%n,)•Pro/Dyna-Pro E'nnlps Imolw-!Q VF Hfnh Parwreence Pump 1ree1111"10 V5-3050&VS+SVRS 'filoama Speen PumpA In' 141anuals Brochures g eWPro VF.. - ----- Moref._....-.._..._...�.�.ry. 30:.,0&VS+SVRS ..."'^"".--^^•.•..^^-...... Varshl3 Soeekl Pump Product SPeci ications --.-_- k'46x..[_.Pro puri zs V._.t J SuperFlo Pumps ENERC;Y EFFfCiE(dT$INGLE SPEED C Sk,pe Max FII mps ProductFul (( Motlel Volta( i"�t HP SF SFNp Primary Listings and Port Size C wb(ewah Spwaalty PUMPS � '--- - I A"" Cor ificationa" (NPI) a�Wit Curve whl.: ,Flo High Per6xrnancrr. 348021 SF PII115/208- -- (Lbs) Key (,trrnp 112FE 230 8.8/4.54.4 1R 1.90 0.95 38 348022 SF-NI- 1151208- E k14,isr�+ri'lorilr Ftigh 3/4FE Z80 8.8/4,54.4 8/4 1.25 0.95 pertormuncc Plnnp UL' 1.5'x 1.5" 38 F ,Snvery.round(+j 348023 SF-NI-IAE 11f1.218.OS.B 1 1.25 t.25 Cr:mmeru;hi 3348M4 SF-NI-1- 1125/20f1- UL' 1.5"x7.5" 38 G tbcrnny f+' 1f2AE 230 14.81f.8-7.4 12 1.10 1.65 UL' 1.5-x 1.5" 348025 SF-NI-2AE 40 H Ptnnp naon.tsoneA(y 206-23'r 9.81@.@ 2 1.10 220 UL' 348026 SF-NI-2- 1.5"x1.5" qg Udlily,arain'%_W..SWWcrt(+J 1/2AE 208.230 11.0/102 2 1.04 260 c Sarlrtizar,(„ �„ 1/2 UL 1.5"x1.5" 54 STANDARD EFFICIENCY SINGLE SPEEo Varv!mc(,.J 1 Product Medd V Full Lone Prima Ustin p SIS HP SF SFNP Primary ga and Water FOattrcer.(+l SF.N--1----�.-_.An�ps -..-_._ CertlflcetlonG' Carlon tflft Curve j 340036 115" 10.8/5,4 1/2 1.@6 .98 __._-- -2 --- 1 (H�l l4bel K= { V?lita rrx>(1�(.,I SF-N1- UL.NSF 1.S'x 1.5" 38 E 314A 11SI230 10.8/6,4 3/4 1.28 .95 UL',NSF' I Replace Parts C+� F 1A 115/230 9. x 1S" 38 F ChGk a,(.;lo exoAno bo 14.2/7.1 1 1.26 1.25 UL',NSF' C110 or•1_1 to w+yP"tat 340039 SF-N1 1- t- 1.5"x 1.5' 38 G 1/2A 11SQ30 18.0 .0 11-1.101.85 UL 2 ,NSF 1.S'x 1.5" 40 H 1 3'!0040 SF-.N1-2A 115/230 224/11.2 2 1.102.2o00. 2 f 340041 SF-N1-2- NSF 1.5"x 1,5" 46 1 230 11.5 2- j 11- 11-1.04 2.60 UL',NSF' 1.5"x 1,5" 54 f ENERGY 1=FNCIFNTTW0 3Pr:En 3460 RPM,LOIN SPEED 1725 RPM 1 Product Model V Fuil t kuttl Prim Listings and Por,'Sif 1 awe Ampa HP SF SFHP g Size(NPT) Carton Wt Curve 341111 SF-N2- Certlflcadons' SucL&Disch. (Lbs) Key I 314A 115 '14.614.7 3/4•1.67 '1.2.5 -~ t 2 ----- j IJL,DISF 'i.5"x 1,5" 39 A F i 340042 SF-WAA 230 6.0/2.3 1 1.25 1.25 + 2 340043 SF-N2-1- UL,NSF 1,5"x 1.5" 39 B G 112A 2M 7.8/3.0 �- 1.10 1.65 ill-'.NSF2 I 1.5"x 1.5" Al C.H 340044 SF-N2-2A 230 1(1.0/3.5 2 1,10 2.201 2 i.fl_.NSF 1 5•`x 1.5" 49 D.1 i:.UU indicates the pump bears a UI_mark slgnHying evaluation to U.S.Standards UL1091 for permanently Connected Swimmrrig pool and Spa Pumps and to Canadian Standards CAN/CSA C22.2 Nn.108-tri I.uquld Pum s ter 2:'NSP Indioatea that pump beers a NSF mark signifying evaluation to NSF Standard so for Swimimingconls O ly(EP I_psre ). Swimming Pools Only. , o http-//www.pent airpool.cOm/PoOl-pr s/pumps-inground-superflo-Puxntps-165.htrn 2/21/2011 I ll-HAYWARlYpow Products I Hayward Industrial Dri A Hayward Industries, Inc.Company Clemmons,NC 2701; 336-.712-9900 ---_,_..-------- _ _ www.hayWardnec.corn C.ERTIFIC.A.TION OF COMPLIANCE Contains: WG1048E or WG11048EW Description: 8" Round. Suction Outlet Cover Ratings: Floor: � 12S GPM Wall-_ 72 GPM Open Area: 8.1 sq-in (.`.crl.iticd tc, (.'amply witla Section 1404 of the Virginia Graeme Baker Act(VGB) Pool & Spa Safety Act Test Restclt.s can be obtained from:www.Haywardnet.com and/or http://www.nsforg/Certified/Pools/ Manuftict.ured: Atter December 20, 2008, by Hayward Pool Products in Jiangsu Province, China and ('lernmons. NC Divisions of Hayward Industries, Inc. 620 Division Street, F1i7abeth,NJ 07207,Phone 908- 355-799.5 Date of fVi f r: The 1,ot Number shown on the product label contains the Year& Month of manufacture. The Iii;tit number represents the year(ex 8 =2008) and the second character the month (A=Jan,B=Feb,H=Aug, I is skipped, .I=`yep, etc) Tested to ANSI/ASME 112.19.8-2007(addendum 8a-2008) per Section 1404 of the Virginia Graeme Baker Act(VGB)Pool & Spa Safety Act. Certified by NSF International, 789 N. Dixboro, Road, Ann Arbor, MI. 48105 1(800)-NSF- MARK. Date of ISWGIO48COC Rev B 6.. -- SPACING BETWEEN - MOUNTING HOLES USED ON FOLLOWI1dG SE RIE S: 40 t3C� ' WG1030AVPAK2 S?1030A:VPAK2 OOQC>Of?0 WG1048A 0. ' PAK2 S:P1044i14V:PAK2 OOHOU UOOL50 , 0 WG104.9.AYPAK2 SP'1049AVPAK2 000(? 000. W.G1051AVPAK2 SP1.051AVPAK2 SUCTION OUTLET 00 coin_ '��G1048E caoo Cl:'O{flC) WG1052"PAK2' s,.P1052AVPAK2 Ot7000 WG1053AVRAK2 SP1 5314V'PAK2 00. :00 J WG1054AV PAK2 SP1054AV PAK2 000 ?OCa O WGI153AVPAK2 SPJ,1.53A.VPAK2 C? OBJ WG1154AVPAK2 SPT154A1/PAK2 QCT HA'YW,ARD'I�ol Protlurts -F_very par)! T"Ably of Contents.,, :)NS ScIecifications __........._ . ......7 . ............................ .. 14We Fafter Dirrwnsuoats in inches Qmt-nni+ Safety Instructions............ „3 AAWWA General Information.................................... _.. .. ..3 PXC75 !P'W125 l;+st,liatiQn................................................... .4 IU\IATf1lL"AASAQP@ PXC9S PXr_1SO hititil Startup............................................... ..4 A 36(9'14) 51 (1,295) Filter Disassembly/Assernbly...................... ..... ...._5 :> 31 (787) 40(1,016) Cartridge Cleaning Procedure...................... _6 `:y-,Wrvi Inspec tia,n/Winterizing..................... . ..6 Air wolAaqo I-ro bleshooting Guide............ ................... . ......_....._7 \/alvn 3tanRrr: .�'" Repair Parts Li:A................ iieignt ProAc�,ro Warranty............................................................... .... ..9 , _.. - 6(41.4) - _• PXC125 _ A t�oa RMS" FIMPIr _- -- ..._ .... . . _.__ t � -4 H - •-- - o .-T-_47___ _. -- ?(20.'7) - Max FI w-ri Flrny 3. D _ ►L ttl^ rain 0 20 40 60 80 100 120 140 60 (0) la.^oia. — (0) (76) 0 5.1) (22.7) (303) (379) (454) (530) (606) FIU1N dA'e CPPN(LPM) - ' , PW,F, r Sr We Drop k.uuirwe f4W all PXC:MOdlels_ .;N t�tl)I E 'A N la mi ension s i n i nc hes. (rollum) Iai#',;ile 2 - Filltl:er Spez:afpcafi(jnS MaadO Nn. PXaC:I'w fP'W95 (`1^ terra P7C((.:15t1i I iltc Area sq.ft. (W) 75 (6 1)F,) 95 (8.8) 125 1,. j 1 So(1--7.(+) Max- Residential Flow Rate GPM(LPM)* 75 (28") 95(.360) 125 (473) 150(5f>t;) Max. Public Pool Flow Rabe GPM(LPM) '2..R(•t00) 36(137) 47(177) 56(212) Max. Operating Pressure PSI (kPa) ;O(:;,:I.' 50(.345) 50(3.4•.5) 50(.145) Max. Continuous Water I'empsrrature F(C) ..:3.4. 1040(40') 104-(40-) 104".(40") NSF listing ig kw public fx-.nl flow rate-,only- b x e x�f.x ,i ,r= Y• i N :. .�� � �' b to �• � N. c� a � �- $ '� 9 .- -lyy tyTlj� A fjZE �. -• �, h Q• 6 �w ' � . S1� 71* Law Offices of Rod Schiath 2187 S Third St L* 3acksonvitte Bch, FL 32250 z 904-372-9351 beach@rod-law.com PROPERTY ADDRESS:350 blit{STREET ATLANTIC BEACH,Florida 32233 SURVEY NUMBER: FL1205.0884 FIIELD WORK DATE:5n4rz012 REVISION DATE(S):(rev 1 5/14/2012) R 12Q5.08B4 0i j N 89°55'52"ESI 9.02'(M) ;X3f�lYDARYSUR�EY G 1/2'FlPNO �/--t "-- DWAL COUNTY > @ K� 1p OR. 02 wo , _ 5T (4C n - TF 0.0cr(P) —,I I 5OC°0900"W 40.00'(M) Oo 5,59'522-28" E J9.9T(M) ✓ I G 1 G0' L,94 OwM S t � v 7 J v V�l 5� t/2'FIP 1� I/2'FIP NO ID rn NO ID 17e1✓���a� y�ys� U I�I I > 6 a y 24.2 t ' wily!; /boss ! 0-81 OFF WOO 141e C S Q jApe t��lO(J - _ NV . CA 15 Sqr = 97JI ooh 6.0 1z.6' i.00N tn_� Propose-j- i��l r/,,A, Wwt`nn LOT 2 / c)) _ `�'ltJ1/hMlNc �Od yy`S�y Os�7 /ptfJ�'t// = 00 a 25TY. J O o O 06RE5/350 V 00 7n v p- 0 0 tli O w AIG City of Atlantic Beach 2.0' i O in Planning and Zoning Department s.rIT T- 30 ! O 0 This approval verifies compliance with applicable .3'zoning, subdivision and other local land1 development regulations, but does not constitute ( 3ALCeNlb " approval for the issuance of permits. Compliance wlth°FIM69 BuitCmg Code an#allotherapplicable _ f /�.� 16edi;Sti5t64rttt,Fedetal permitting requirements 1Y I ��.P must be verified by signature of the City of Atlantic `� f Beach Building Official prior to the Issuance of e Building Permit. Approved By ,�� Date: telOil m / o I hereby certify that this Sketch of Survey of the hereon described has been mode under 1/2"I'll' 1/2'FIP my direction, �` t of my knowledge and NO ID 50.00'(P) NO ID belief, it is andare presentation of o S.C59°53'42"W 50.00 (M) survey that ee-is tlgtechnical g standards a fpr>!tr bo Board Of 30 0 15 30 Profession escribed in Chapter 5J- de. STATE OF Q GRAPHIC SCALE (In Feet) N State of Floe rofessional Surve tmd Alopper rro� 1 inch = 30' ft- o. r o se o. y^L SURVEY0� use of This Survey for Purposes other than Intended,Without written verification,will be at the User's Sole Risk and Without Liability to the Surveyor. Nothing hereon shall be Construed to Give ANY Rights or Benefits to Anyone Other than those certified. ROOD INFORMATION: POINTS OF INTEREST By performing a search with the local governing municipality or www. NONE VISIBLE fema.gov,the property appears to be located in zone X.This Property was found in CITY OF ATLANTIC BEACH,community number 120075,dated 04/17/89. CLIENT NUMBER:RS12 636 i DATE: 5/14/2012 Florida ' AFFILIATE Title Association BUYER:GEORGE KIROU MEMBERS SELLER:RANDALL RUTLEDGE ' CERTIFIED TO:GEORGE KIROU;ORT;JPMORGAG CHASE BANK,N.A. www.surveystars.com Land Surveyors, Inc. P 866-735-1916• F866-744-2882 This is page 1 of 2 and is not valid without all pages. LB•7337 12220 Towne Lake Drive,Suite 55•Ft.Myers,FL 33913 3K)RfOF9JRYEv -- --- -- - = ==e 2 Z_ .. : c. 'a - :aII pages. } 3W TION: st 1111ficit 7 9J ION`A',ATLANTIC BEACH according to the plat thereof,as recorded in Plat Book 5,Page 69 of the Public Records of ' UVPI courey,Porida. [L4� 1 I DIS 91E'"FiC SURVEYOR NOTES: BEARfNG REFERENCE OF NORTH 0 DEGREES 00 MINUTES 00 SECONDS EAST IS BASED ON THE ASSUMED BEARING OF THE WESTERLY ROPER1Y LINE OF LOT 21,BLOCK 7,LOCATED WITHIN SUBDIVISION "A",ATLANTIC BEACH,ACCORDING TO THE PLAT THEREOF,AS ECORDED IN PLAT BOOK 5,PAGE 69 OF THE PUBLIC RECORDS OF DUVAL COUNTY,FLORIDA. F-: ENERAL SURVEYOR NOTES: Description used to perform this survey was supplied by others. This survey does not determine or imply ownership. s_:aey only shows improvements found above ground. Underground footings,utilities and encroachments are not located on this survey map. a septic tank,or drain field shown on this survey,the location is approximate,and was determined by visual above ground inspection only,and cannot :e-e:ied on for accuracy. ti s "?is son ey is exclusively for the use of the parties to whom it is certified. Additions or deletions to this survey map and report by other than the signing party or parties is prohibited without written consent of the signing party or parties. are in feet and decimals thereof. ,e To Varying construction standards,house dimensions are approximate. 4-y FEMA flood zone data contained on this survey is for informational purposes only. Research to obtain such data was performed at vtnrrw.iema.acv. Pi A`corners marked asset are at a minimum a W'diameter,18"iron rebar with a cap stamped LB#7337. you are reading this survey in an electronic format,the information contained on this document in only valid if this document is electronically signed as specified :,faapter 5.1-17.062(3)of the Florida Administrative Code. The Electronic Signature File related to this document is prominently displayed on the invoice for this s--.eyvvhich is sent under separate cover. Manually signed and sealed logs of all survey signature files are kept in the office of the performing surveyor. If this i wc.ment is in paper format,it is not valid without the signature and original raised seal of a Florida Licensed Surveyor. ^gess otherwise noted,an examination of the abstract of title was NOT performed by the signing surveyor to determine which instruments,if any,are affecting ,^is croperty. Re symbols reflected in the legend and on this survey may have been enlarged or reduced for clarity.The symbols have been plotted at the center of the field ocabon,and may not represent the actual shape or size of the feature. } JEGEND f. {II SURVEYOR'S LEGEND 3a.wCA91 ii1E P/C AIR CONDITIONING ID. IDENTIFICATION SEW SEWER 4 � ! B.R. BEARING REFERENCE INT. INTtR5ECT1ON S.F. SQUARE FEET BLE. BLOCKIR fRON ROD SIDH SET DRILL HOLE B.C. BLOCK CORNER IF IRON FIFE 51RC SET IRON ROD 4 CAP 1 >^•.A2t B.R.L. BUILDING RESTRICTION UNE L LENGTH 5N SET NAIL {{ 55MT. BASEMENT LBO LICENSE O-BUSINESS 5N4D SET NAIL 4 DISC t MW BAYMO(WINDOW 1.50 LICENSE I-SURVEYOR 5TY. STORY :;�..5LOCK WALL (C) CALCULATED (M) MEASURED 5.T.L SURVEY TIE UNE C CURVE N.R. NON RADIAL 5V 5EWER VALVE =A^-_aiK w WIRE FENCE CATV CABLE TV.RISER N.T-5. NOT TO SCALE 5/W SIDEWALK I *Ort..-Na C.B. CONCRETE BLOCK O.C.5. ON CONCRETE SLAB 5.W. SEAWALL CNN. CHIMNEY O.G. ON GROUND TEL TELEPHONE FACILITIES Ilt>, C.LF. CHAIN LINK PENCE O.M.L. OVERHEAD UNE T.O.B. TOP OF BANK j C.O. CLEAN OUT O.RB. OFFICIAL RECORD BOOK TX TRANSFORMER CONC. CONCRETE OH. OVERtANG TM. TYPICAL E'OG' 3 WAm C.V.G. CONCRETE VALLEY GUTTER CVA OVERALL W/C WITNE55 CORNER CLL CENTER LINE CVS OFFSET WIF WATER FILTER *CCC CONCRETE 05 CONCRETE SLAB FKN PARKER-KALON NAIL W.F. WOODEN FENCE CMR COVERED PORCH PSM PROFESSIONAL SURVEYOR WM WATER METUNALVE BOX C5W CONCRETE SIDEWALK AND MAPPER WV WATER VALVE BRICK w TILE COR. CORNER PL5 PROFESSIONAL LAND SURVEYOR V.F. VINYL FENCE P I (D) DEED (P) PIAT I.. LrJ 07W DRIVEWAY PR POOL EQUIPMENT #A-.5k OOVERED AREA D.F. DRAIN FIELD PLT PLANTER EUB ELECTRIC UTILITY BOX PP PINCHED PIPE ) SNCL ENCL05URZ P.B. PLAT BOOK Ew. ENTRANCE P.L. POINT OF INTERSECTION A.E. ANCHOR EASEMENT e BENCH MARK E.O.P. EDGE OF PAVEMENT P.O.D. POINT OF BEGINNING C.M.E. CAW.MAINTENANCE EMT. i= - CALCULATED POINT t.O.W. EDGE OF WATER P.O.C. POINT OF COMMENCEMENT C.U.E. COL■r1Y UTILITY E5Mr. .� CENTRAL ANGLE a DELTA FA. FENCE UNE P.T. POINT OF TANGENCY D.L DRAINAGE EASEMENT a CONTROL FORT F/P FENCE POST P.C. POINT OF CURVATURE E5MT. EASCM11W ! ■ CONCRETE MONUMENT (F) FIELD P.C.C. POINT OF COMPOUND CURVATURE I.tJE.E. E5MT. i A CATCH BASIN F.F. FINISHED FLOOR P.R.C. POINT OF REVERSE CURVATURE WJU. WJWATION EASEMENT �... ELEVATION FPL FLORIDA POWER 4 LIGHT P.C.P. PERMANENT CONTROL POINT LAE. LIMITED ACCC55 99MT. F/DH FOUND DRILL HOLE P.RM. PERMANENT REFERENCE MONUMENT L.B.E. LAR)ISCAEE BUFFER e5MT. `J FIRE HYDRANT RFC POUND IRON PIPE 4 CAP R RADIUS or RADIAL LM.E. LAKE OR LANDBCAFt 0 MANHOLE FIRC FOUND IRON ROD 4 CAP (W RECORD MAM(rEU.M1'..E EA DAW ® TREE FIR FOUND IRON ROD RES. RESIDENCE M.E. MAWMIt:" EASEdEif UTILITY OR UGHT POLE FIF FOUND IRON FIFE RAV RIGHT OF WAY P.U.E. FURIC ''EASEMENT f WEl FCM FND.CONCRETE MONUMENT (5) SURVEY RO-E. ROOF C 2114 MMT. w FN FOUND NAIL 5.15.1- 5tT5ACKUNE 5.W2. SIDEWA, ;_11M W / COMMON OWNERSHIP FN4D FOUND NAIL 4 D15C 5.C.L SURVEY CLOSURE LINE 5.W.M.E 5TC1:' FND. POUND SCR SCREEN 15MT ' GAR GARAGE Wh SET(NULL HOLE GM GAS METER 5EP. SEPTIC TANK _ I ---RONIC SIGNATURE: PRINTING INSTRUCTIONS: OFFER VALID ONLY FOR: GEORGE KIROU -_._c':o Electronically Sign'all of the PDFs sent 1.Whsle viewing the survey in Adobe Reader•select the 7-=5,you must use a hash calculator.A free "Print"button under the"File"tab- -e hash calculator is available ati r — — — — — — — — — — — - 2 Select a printer with legal sized paper. 3. Under"Print Range",dick select the"AAI"toggle. I 'c;iectronically Sign any survey PDF: '..Save the PDF onto your computer. ( 4. Under the"Page Handling"section,select the number 2.Use the online tool at of copies that you would like to print. ( I POOL• •FENCE -ADDITION, S. Under the"Page Scaling"selection drop down menu, i :o browse for the saved PDF on your computer. select"None." 3.Select the Hash Method as SHA. 6. Uncheck the"Auto Rotate and Center"checkbox. 4.Click Submit. ( 25% off I 1 1 7. Checkthe"Choose Paper size by PDF"checkbox. I burPDFiselectronically signed ifallofthe ! (UPTO$500) cltaTacters in the SHA-1 code submitted by STARS 8. Click OK to print. I ANY FUTURE :,.�the code which is produced by the hash I; 1 TO PRINT IN BLACK+WHrre I SURVEYING SERVICES I tabatavar.Ifthey match exactly,your PDF is Ili 1. In the main print screen,choose"Properties". I ON THIS PROPERTY it electroFtically signed.If the codes do not match 2. Choose"Quality"from the options. I i I Offer valid only for the buyer as listed on the ' I eca ,your PDF is not authentic ( 3. Change from"Auto Color"or"Full Color"to first page of the survey.Total discount not to exceed$500. "Gray Scale". I _ I Exacta Land Surveyors,Inc. www.surveystars.com LB47337 P 866-735-1916• F 866.744-2882 - 1222o Towne Lake Drive,Suite 55•Ft.Myers,FL 33913 RECEIVFD City of Atlantic Beach MAY 2 2013 ! APPLICATION NUMBER .,� s s� Building Department (To be assigned by the Building Department.) 800 Seminole Road Y: y Z / Atlantic Beach, Florida 32233-54 /S 6 q1 Phone (904)247-5826 • Fax(904)247-5845 E-mail: building-dept@coab.us Date routed: Z �� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /i� c� ent review required Yes No B Applicant: � ro r0 1h ;��Ianning_&Z .P Tree Administrator Project: / �Q )n(fit' /) ub! Works —� u tic Utilif s Public Safety Fire Services Review fee $ Dept Signature'_ Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. [-]Denied. (Circle one.) Comments: BUILDING PLANNING & ZONING �� Reviewed by: Date: TREE ADMIN. Second Review: A roved as revised. ❑ pp ❑Denied. 4PUBLI Comments: UTILITIIC SAFE Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05114109 City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road /3 z 6 1/ _., Atlantic Beach, Florida 32233-5445 _/ .. Phone(904)247-5826 • Fax(904)247-5845 �r E-mail: building-dept@coab.us Date routed: 2 �� City web-site: http://vmw.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: � /Q�/y d- ent review required Yepf No Bui Applicant: f0 1h fanning &Z Tree Administrator Project: //1�1 X00 J,n arac�n ubl Works u lic Utilit• s Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: s o?©-1 3 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. [-]Denied. Comments: Reviewed by: Date: Revised 05/14/09 rS�,Lv,,J City of Atlantic Beach APPLICATION NUMBER JS S, Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 J Phone(904)247-5826 • Fax(904)247-5845 x�d;;t�~ E-mail: building-dept@coab.us Date routed: 2 �� City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: �._ � �1/y J ent review required Yes No Buil ' Applicant: Fanning &Z Tree Administrator Project: _:�/)J f m X60 �ngrQah ubl' Works u lic Utiliti s Public Safety Fire Services � e % x Dept Signatt e Other Agency Review or Permit Required Review or Receipt Date of Permit Verified BY] Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [ pproved. ❑Denied. (Circle one.) Comments: BUI ANNING &ZONING sla'14"M Reviewed by: Date: 246 TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14109 �1 Cit of Atlantic Beach RECEI�VTED y,s ' Y APPLICATION NUMBER Building Department MAY 2 1 O�3 (To be assigned by the Building Department.) Y , 800 Seminole Road Atlantic Beach, Florida 32233-5 �? Phone(904)247-5826 • Fax(9A7- ----_ .�jjt as E-mail: building-dept@coab.us Date routed: 2 City web-site: http://vmw.coab.us &= —I APPLICATION REVIEW AND TRACKING FORM Property Address: �� jr ent review required Yes No Buil Applicant: f (l, tanning &Zoning Tree Administrator Project: Jim :nal )j'l(,�aah ubl Works Qlic Utili-f s Public Safety Fire Services evie�w ft epi s 9�tl e Other Agency Review or Permit Required Review or Receiptof Permit Verified By Date Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05114109 CITY OF ATLANTIC BEACH ss� 800 SEMINOLE ROAD N� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 !J33 Application Number . . . . . 13-00002691 Date 12/06/13 Property Address . . . . . . 350 6TH ST Application type description SWIMMING POOL/SPA Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 20000 ----------------------------------------- Application desc NEW POOL --------------------------------------- Owner Contractor - ------------------------ ----------------------- GEORGI, KIROVALL STRONG, INC 307 BRAYDEN WAY 50 AUDUBON LANE LAYTON UT 84041 FLAGLER BEACH FL 32136 (904) 347-6108 -- ------------------------------------------------------------------------- Permit ELECTRICAL PERMIT Additional desc . . Sub Contractor . . HAPPY CAT ELECTRIC INC. 00 Permit Fee . . . . 95 . 00 Plan Check Fee Issue Date Valuation . . . . 0 Expiration Date . . 6/04/14 ------------------------------------ Special Notes and Comments POOL - Wellpoint (if used) must discharge into vegetated area 10 ' minimum from street or drainage feature (swale, structure or lagoon) . Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Shappelle ' s and Waste Management . ) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities . Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. Keep roadway cleaned at all times . 2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE REQUIRED INSPECTIONS : *POOL STEEL *ELECTRICAL GROUNDING AND BONDING *FINAL (PUMPS MUST BE RUNNING FOR FINAL) SWIMMING POOL SAFETY INSPECTION REQUIRED POOL SHALL BE NO CLOSER THAN 5 ' FROM REAR OR SIDE PROPERTY LINES . _ ----------------------------------------- ___ _ -------_ _____ __________ ----------- _ �+ nC� sTTpr F PERMIT QtAk1WOVF*@J?LV IN ACCORDANCE WITH ACLCITY"VI�IFI�A BE K7t`vlmltYaPFt��fl THE FLOR13V 00 BUILDING CODES. �t I"�'`�rl��. CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD r� ATLANTIC BEACH,FL 32233 v INSPECTION PHONE LINE 247-5814 Page 2 Application Number 13-00002691 Date 12/06/13 Other Fees _______ . . STATE ELEC DBPR SURCHARGE ----- Fee summary Charged Paid -- Credited _ ------- . 00 ----- ---------- 95 . 00 . 00 Permit Fee Total 95 . 00 00 . 00 4 . 00 4 . 00 . 00 Plan Check Total . 00 00 . 00 Other Fee Total 00 . 00 Grand Total 99 . 00 99 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, FL 32233 Ph (9t0�4) 247-5826 Fax (904) 247-5845 JOB ADDRESS: �� +� S�r�� PERMIT# JEA INFORMATION REQUIRED ON ALL PERMITS 36 o AMPS 7-1-1,0 VOLTS PHASE VALUE OF WORK S-15 6�' a NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole --Residential(Main) Service ❑0-100 amps ❑101-150amps ❑151-200amps ❑ amps #of Meters Commercial(Main)Service 0-100 amps .101-150amps -151-200amps ❑ amps CT Service amps ❑ Conductor Type Size ❑Multi-Family(Main)Service ❑0-100 amps -i 10 1-1 50amps ❑151-200amps ❑ amps #of Unit Meters ❑Temporary Pole ❑ amps SERVICE UPGRADE - amps -i CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) 100 amps ❑150amps ❑200amps amps [I CT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps 31-100amps 101-200amps Appliances: P 0-30am s 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS KVA ❑Motors hp Swimming Pool i-- Sign �Smoke Detectors_Qty ❑Transformers FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK S Qty volts/amps REPAIRS/MISCELLANEOUS 'Replace Burnt/Damaged Meter Can ❑Safety Inspection ❑Panel Change OH to UG G Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. f Phone Number Property Owners Name -.TGCt^ Electrical Company �-��' w�`n� Office Phone 90q 71(o yFaxjoq Z3�'3oSd' Co. Address: 37� -7Lek~� 1- j��acL — City ��c l�Sones ��L State Zip 321-04 State Certification/Registration# 17C 0001105"' License Holder(Print): f2 6 f a No of ff Notary Public-state of Florida day Of 20 .; • •= My Comm.Expires Oct 28,tot orn and subscribed before me is N, Po� Commission #OD 927�9� Cianatiire nfNntnry Pnl�lir %FOg;;°`'� Bonded Thrn.o