358 19th St 2013 HVAC I. I% ,
N CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Dills)
Application Number . . . . . 13-00002749 Date 5/29/13
Property Address . . . . . . 358 19TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU 4 TONS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CRUTCHFIELD AMY & SMITH MIKE OCEAN STATE HEAT & AIR, INC.
358 19TH ST 1476 ATLANTIC BLVD.
ATLANTIC BEACH FL 322334536 NEPTUNE BEACH FL 32266
(904) 249-8251
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 107 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/25/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 107 . 00 107 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 111 . 00 111 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
�A C,C3-1—7
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845
JoB ADDRFss: S PERMff#
PROJECT VALUE $ 1 S I-
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating_
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INS
ARI# D sib
Air Conditioning: Unit Quantity— Tons Per Unit H REQ
Heat: Unit Quantity— BTU's Per Unit 4A,(VI) Seer Ratid&--D:-]�
Duct Systems: Total CFM REQUIRED
FT" PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans) ,
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Pqy-��A Phone Number _2H� - 211 C)
Mechanical Company CC ect"-) )Stcjf— A-c 'Y Office Phone-2q�2SI Fax-Lqa2ai'fi-
L
city N U�Ue- &11 State F-� Zip
Co.Address: 1.(A -N�C, 11\A - I
I- rtification/Registration#
License Holder(Print):
Notarized Signature of Lkense Holder
ie,
r 4,edTore
w V-Qr. e me thi 2 6'14n day of 203
S rn and sutisc ib S
P I ic
YVETTE P.MORALES ub I , 1,1-p , n
V.
Sipnaap lic 1-44-�
NOTARY PUBLIC
STATE OF FLORIDA �j
Coffvn#EE879174
Expires&=1 7
05/29/2013 08:51 FAX 9042488949 OCEAN-STATE-A/C ATLANTIC-BEACH 002/003
A: 111111101LI CERTIFIE
L
Certificate of Product t<atin2s
AHRI Certified Reference Number. 5290858 Date: 5/24/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Alr-Source
Outdoor Unit Model Number: 4TWZ004881
Indoor Unit Model Number: *AM8AOC48V41
Manufacturer:TRANE
Trade/Brand name: XL201 WEATHERTRON
Manufacturer responsible for the rating of this system combination Is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unita%Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AH -sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 45500
EER Rating(Cooling): 12.25
SEER Rating (Cooling)., 17.75
Heating Capacity(Stuh) @ 47 F: 44500
199gion IV HSPF Rating (Heating): 9,20
Heating Capacity(Btuh) 0 17 F: 26000
SMITH, AMY MC0377
358 19TH ST. 246-2190
ATL. BCH, FL 32233
SYS CIO 5/29/13
RaorigN folil t)y-An mlanslk�') rilicale a voluwarV rvote or preWDU Sly P11blighed dal.B,unle!ls ac=)n�p,�n led w1h a WAS,wi1ch indiww an invowntary ferElte.
DISCLAIMER
AW do"s not endorse the productl listed on this Certificate and nukkes no rtpraz�cntatlorl warrapities or guarantees as to,and assumes no responsibility rpe,
thq product(s)119tod on this Certificate.AHRI expmsally discialing all llnl)lllry for Cil of any kind adeing out of the use or parforll of this product(s),or ll
viiaull altarallon or detu Ilated an thia Certificate.Certified ratings are valid only for modtio and copivourations irtod Ili the directory at veww.alindirecLoly.org.
TERMS AND CONDITIONS
This CmMi and lut i;ontontp rin:peopriatary prodUCtIll ol Thia Cortlflcat&shall owy he used for Incilvidpal parsonnI and ronflaev�Ual reference purposes.
The contentt oll Gv%ifirate rrialy n"in wbole or in paM be reproduced;copied;d1sBernfinated;entarod into a computer databa5e;or otherwise utilized,in any
form or thatinar or by any Mipans,Wept foril user's Incilvidupi,porsonal und conilldonlial Werevica.
CERTIFICATE VERIFICATION
The Inforrvationfor the modal clitad on t,4ia cortillraturan be v6mified A "IMF Air-conditioning,i400iling.
rhck on"Vorlry Nnk and anter the AHPJ Cortill Raferencilli Number arid tha date an
which the certifitate was ll whl�:h hA fttrd illvvc,and the Certificate No.,which ia listed below. ond Refrigeratim Instiliute
Q2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO,: 130138a47779684()10
05/28/2013 08 �52 FAX 9042498949 OCEAN-STATE-A/C ATLANTIC-BEACH Ia003/003
ACCA Manual "J" Heat Load Calculation Date 05129113
Customers Name Amy Smith Location 358 19th St,AB
Type of Construction Heat Transfer Multipliers Area or 6TUH
Exposure Notes HEATING COOLING Length HEATiNG COOLING
1 IGross Wall 1,704
2,3 Windows
North Al, N, 2 29.0 16.0 25 812 448
East& West Al, E &W, 2 29.0 46.0 340 9,860 15,640
South Al, S. 2 29,0 25.0, 28 812 700
4 Doors
Front Solid Wood -Panel 27.0 15.8 60 1,620 948'
Patio Solid Wood - Storm 16A 9.7 0 0 0
I Other SIdq GI Or, S. 2 32.6 25 0 0 0 0
5 Net Wall 1,248
Area I R- 11, 1/2"Asp. Brd. 3.2 1,9 1,248 3,994 2.371
Area 2 R-13, 1/2"Asp. Brd. 3,0 1.8'. 0
I Area 3 R- 13, 1/2"Asp. Brd. 3,0 0 0
6 Ceilings
Area I Attic, R-22 1.9 0 0
Area 2 Attic, R-30 1,3 2,477 3,220 3,1'716
I Area 3 'Attic, R- 19 2.1 2,3 0
7 Floors
Area I Slab 40.5 0'.0 109 4,415 0
Area 2 Open Crawl, Carpet,-F 2.8 I'll' 288 806 '317
8 Infiltration Winter Summer Avg Cilng Ht
I Poor>2100 1 8 18,201 3,640
9 JSub Total BTUH Loss 43,740
10 IDuct BTUH Loss 2,187
11 ITOTAL HEATING LOAD 45,927
12 1 People and Appliances Bedrooms 4 3,600
13 ISub Total 13TUH Gain (Structure) 31,380
14 JE)uct BTUH Gain Location Attic 15% 4,707
15 jTq-rAL SENSIBLE 36,687
16 1 nfiltraton Latent Gain Infit, CFM 165 5,738
17 People Latent Gain #People 4 920
19 TOTAL LATENT 6,658
19 ITotal Cooling Load '42,745