Loading...
2077 Beach Ave 2013 HVAC CITY OF ATLANTIC BEACH 1 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002759 Date 5/29/13 Property Address . . . . . . 2077 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 4 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SHEPHERD ROBIN W & CHRISTINA DONOVAN HEATING & AIR 2077 BEACH AVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322335934 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/25/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDREss: 0 1] �, �� �/t� PERMIT# PROJECT VALUE$ y p NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit _ Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & ]HEATING SYSTEM INSTALLATION Air Conditioning; Unit Quantity Tons Per Unit ARI# Heat: RE Duct Systems: o��Mtr� i BTU's Per Unit Seer Rah n REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's ALL OTHER GAS PIPING Elevators/EscalatorsHeat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Taniklss(gallons) We OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months_I hereby certify that I haveread this application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified )r not The permit does not give au to violate the provisions of any other state or local law regulation construction or the performance of construction ?roperty Owners Name kob;v-N f Cs�l Phone Number Mechanical Company l��t vvC n -t �- lei" Office Phone Zlt 1-3?KS-Fax ZH 1-31 9S �o. Address: 3I S c. S City owK t34U c 1. State C Zip 3 aaS� :icense Holder(Print): -AU&w, �rtav/G n State Certification/Registration# G�Go3 b Votarized Signature of License Holder Sworn and subscribed before me this `� da of /a 20 YEE tate of Florid S' of Notary Public A. # . Hughesn EE 186278 016 Project Summa Job. + wrightsoft Date: 5/29/13 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south, Jacksonville Beach, Fl-32250 Phone: 241-3785 Email brandon@donovanac.com • • • For: She hers 2077 Beach AVE, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21477 Btuh Structure 17679 Btuh Ducts 7576 Btuh Ducts 15456 Btuh Central vent (57 cfm) 1804 Btuh Central vent (57 cfm) 1244 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30857 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 34379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2029 Btuh Ducts 2778 Btuh Heating Cooling Central vent (57 cfm) 2047 Btuh Area (ft' 2336 2336 Equipment latent load 6854 Btuh Volume �ft3) 21024 21024 Air Changes/hour 0.38 0.16 Equipment total load 41233 Btuh Equiv. AVF (cfm) 132 56 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make carrier Make carrier Trade Trade Model 25HNB648c Cond 25HNB648c ARI ref no. 5480779 Coil FE4AN005 ARI ref no. 5480779 Efficiency 9 HSPF Efficiency 16 SEER Heating input Sensible cooling 32292 Btuh Heating output 45903 Btuh @ 47°F Latent cooling 13840 Btuh Temperature rise 27 °F Total cooling 46132 Btuh Actual air flow 1538 cfm Actual air flow 1538 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft Right-Suite®Universal 7.1.01 RSU05996 2013-May-29 08:11:53 C:\Users\Sales\Documents\Wrightsoft HVAC\4 TON.rup Calc=MJ8 Orientation=N Page 1 I