Loading...
1305 Violet St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ►� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002772 Date 5/31/13 Property Address . . . . . . 1305 VIOLET ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ HARVEY, ROBERT ONE HOUR AIR 1305 VIOLET STREET 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 322332635 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/27/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 .TOB ADDRESS: /-7C) 1 V IOC S ) PERMrr# PROJECT VALUE $—Z775, — ARI# �/9 3/ 7 9 —2 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Z Heat: Unit Quantity 1 BTU's Per Unit 2 C Seer Rating S Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisio s of any other state or local law regulation construction or the performance of construction. Property Owners Name �( �L % l 42 Ve-` Phone Number 3 Ll 4 - SC3 /8 Mechanical Company ��N�_doupl- - f/z Office Phone 24 k3 tU 7 Fax 2 7- 5 Z6 Co. Address:l 19P W/�Y►Rn` r P,0 City �C / State-L-Zip Z-T;?ZM,,1 License Holder(Print): CrZqia F—DOY tate Certi f gi ation Notarized Signature of License Holder Before me this�_dUfj 20 Signature of Notary Publi Project Summa Job: 123238 wrightsoft Summary Date: 5/31/2013 Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Project • • For: ROBERT&AMBER HARVEY 1305 VIOLET ST,ATLANTIC BEACH, FL 32233 Phone: 904-349-5878 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18402 Btuh Structure 17917 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18402 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17917 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2273 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 976 976 Equipment latent load 2273 Btuh Volume(ftp) 7808 7808 Air changes/hour 0.45 0.23 Equipment total load 20190 Btuh Equiv. AVF (cfm) 59 30 Req. total capacity at 0.75 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Model SSZ140241 Cond SSZ140241 AHRI ref 4431297 Coil AVPTC183014 AHRI ref 4431297 Efficiency 0 HSPF Efficiency 14.5 SEER Heating Input Sensible cooling 18000 Btuh Heating output 0 Btuh @ 47°F Latent cooling 6000 Btuh Temperature rise 0 °F Total cooling 24000 Btuh Actual air flow 0 cfm Actual air flow 816 cfm Air flow factor 0 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft" 2013-May-3106:32:15 � Right-Suile®Universal 2012 12.1.07 Right J®Mobile Page 1 ' '` ...\wstmp\4cfabf7d-59fa-4183-b4c3-2bec1 cOdd584.rup Calc=MJ8 Front Door faces: W III www.ahiidirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 4431297 Date: 5/31/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: SSZ140241A* Indoor Unit Model Number: AVPTC183014A* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING AND HEATING, ENERGI AIR Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 22800 EER Rating (Cooling): 12.20 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh) @ 47 F: 23600 Region IV HSPF Rating (Heating): 8.30 Heating Capacity(Btuh) @ 17 F: 14500 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION � ® The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enterthe AHRI Certified Reference Number and the date on 9%0 No +IIILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130144840956927314