Loading...
399 5th St HVAC 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002818 Date 6/06/13 Property Address . . . . . . 399 5TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ JOCHER BARBARA B TRUST ONE HOUR AIR 399 5TH STREET 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 322335345 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc - - Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/03/13 ------ ------------------------------------------------------------- -------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service Multi CERTIFIEDTM between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org 11 Certificate of Product Ratings AHRI Certified Reference Number: 4888609 Date: 6/6/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: ASZC160481A* Indoor Unit Model Number: CA*F4961*6D*+MBVC2000**-lA*+TXV Manufacturer: AMANA HEATING AND AIR CONDITIONING Trade/Brand name: ASZC16 SERIES Manufacturer responsible for the rating of this system combination is AMANA HEATING AND AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 47500 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 16.00 Heating Capacity(Btuh) @ 47 F: 47000 Region IV HSPF Rating (Heating): 9.75 Heating Capacity(Btuh) @ 17 F: 34000 Ratings followed by an asterisk indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wwmahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on On ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130150076930479728 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: S7 If -<MR�e-7— PERMrr# PROJECT VAL UE $ ARI# 1/098 60!2 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit q Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty— Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. W -73 Property Owners Name 8AlQ66" Phone Number (—, —16 Mechanical Company C�e- Oc�urz- A Office Phone 2Y(--3107Fax 2,q7--(;-S-Z6 city4bLqz—[c � state EL zipS 22-75 Co. Address: mAmx—1 License Holder(Print): Ca'a Llig��14,-Cpftification/Registration# raC SN9—z) Notarl—i-,", er t3RAHAM My COMMISSION 4 0r)957760 d 03 I fore me this EXPIRES:February�:14,2014 yp I 's .0 Smded Thru Notary Public Undenvriters gnature of Notary Public Job: 123373 Project Summary Date: 61612013 wrightsoft Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Project Information For: BARBARAJOCKER 399 5TH STREET, ATLANTIC BEACH, FL 32233 Phone: 904-674-1073 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 'F Inside db 75 'F Design TD 35 oF Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 43255 Btuh Structure 38613 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 43255 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 38613 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 0 Structure 4251 Btuh Fireplaces Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft� 2112 2112 Equipment latent load 4251 Btuh Volume (ft) 21120 21120 42864 Btuh Air changes/hour 0.41 0.21 Equipment total load Equiv. AVF (cfm) 144 74 Req. total capacity at 0.80 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA Trade AMANA Model ASZ160481 Cond ASZ160481 AHRI ref 4888609 Coil CAPF4961 D6D AHRI ref 4888609 Efficiency 0 HSPF Efficiency 16 SEER Heating input Sensible cooling 38000 Btuh Heating output 0 Btu h @ 47'F Latent cooling 9500 Btuh Temperature rise 0 'F Total cooling 47500 Btuh Actual air flow 1758 cfm Actual air flow 1758 cfm 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh Air flow factor 0 in H20 Static pressure 0 in H20 Static pressure Space thermostat Load sensible heat ratio 0.90 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jun-06 07 30:23 wrightSOft Right-Suite@ Universal 2012 12.1.07 Right J@ Mobile Page 1 ...\wstmp\2b6gac9e-4788-4967-9edO-d9f1 18528da4.rup Calc=MJ8 Front Door faces: S