348 8Th St 2013 HVAC CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
J ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002791 Date 6/04/13
Property Address . . . . . . 348 8TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
3tons, 36K
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
MULLINS SUSAN E TROPIC HEATING & AIR
348 8TH ST 750 MAYPORT RD
ATLANTIC BEACH FL 322335436 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/01/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904) 247-5845
.TOB ADDRESS: c/, `S'/Z PERMIT#
PROJECT VALUE $ ARI# Y719971" REQUIRED
Air Handling Equipment Only YAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity l Tons Per Unit j
Heat: Unit Quantity / BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name sa /Y" S Phone Number
Mechanical Companyher s V.PlfK Office Phone ZyI 1?dT Fax 2,Y -2-4�Z
Co. Address: 7 SU �� /%�[ City State_C�2 Zip Z Z?5
License Holder(Print): - State Certification/Registration
Notarized Signature of License Holder
KAREN E.PANTFOEDER Before me thil
_day of 20 �3
NOTARY PUBLIC
STATE OF FLORIDA Signature of Notary Publi
Comm#EE064448
Expires 3/4/2015
This combination qualifies for a Federal Energy
Efficiency Tax Credit when placed in service
between Feb 17, 2009 and Dec 31, 2013.
certificate of Product R
AHRI Certified Reference Number: 4799871 Date: 6/4/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 226ANA036****A*
Indoor Unit Model Number: FV4CN(B,F)005
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: PREFERRED 16 PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 35200
EER Rating (Cooling): 13.00
SEER Rating (Cooling): 16.00
Heating Capacity(Btuh) @ 47 R 36000*
Region IV HSPF Rating (Heating): 9.00*
Heating Capacity(Btuh) @ 17 F: 22200
Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at wrvw.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthe model cited on this certificate can be verified at ,,vw.ahridirectary.org, Air-Conditioning,Heating,
dick on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on AMU 00 I./ and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certrt tate No.,which is listed below.
02013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130148211490270256
Proj1ect Summary Job: Mullins
J Summary Date: 6/3/2013
Entire House By: Tropic Heating&Air C...
'MMOMM
gow6go is om Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431
Proiect Informatian
For: Susan Mullins, Tropic Heating&AirConditioning,inc.
348 8th St., Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Notes:
Design • t
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 21163 Btuh Structure 20228 Btuh
Ducts 4843 Btuh Ducts 4362 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 26006 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 24590 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2149 Btuh
Ducts 1285 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 1408 1408 Equipment latent load 3434 Btuh
Volume(ft) 11264 11264
Air changes/hour 0.45 0.23 Equipment total load 28024 Btuh
Equiv. AVF(cfm) 84 43 Req. total capacity at 0.70 SHR 2.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual air flow 1115 cfm Actual air flow 1115 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Jun-03 17:11:00
wrightsaft Right-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1
' ...\wstmp\Oa7262f6-Od7e-4d9fa951-07d6bf475d44.rup Calc=MJ8 Front Door faces: N
light J®Mobile Report Job: Mullins
p By: Tropic Heating&Air C...
Entire House
Ital,riri� Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431
Project • •
For: Susan Mullins, Tropic Heating&AirConditioning,lnc.
348 8th St., Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75
Elevation: 43 ft Design TD(°F) 35 16
Latitude: 30°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8
Dry bulb(°F) 35 91 Infiltration:
Dailyrange(°F) - 17 ( M ) Method Simplified
V1btbulb(°F) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh %of load
Walls 3.4 3501 13.5 V%dls DuJs
Glazing 30.1 4239 16.3
Doors 13.5 433 1.7
Ceilings 2.8 3946 15.2 Qaft
Floors 4.1 5834 22.4 Irfiltra5m
Infiltration 2.6 3210 12.3
Ducts 4843 18.6 C1ta
Piping 0 0
Humidification 0 0 Calirgs Ficas
Ventilation 0 0
Adjustments 0
Total 26006 100.0
• •
Component Btuh/f8 Btuh %of load
Walls 2.6 2722 11.1 WAIS Interrd Gdrs
Glazing 40.5 5707 23.2
Doors 11.4 367 1.5 ads
Ceilings 4.3 6022 24.5
Floors 2.0 2748 11.2 Gla&g
Infiltration 0.6 773 3.1 Irfiltraticn
Ducts 4362 17.7
Ventilation 0 0
Internal gains 1890 7.7 Other Haas
Blower 0 0
Adjustments 0 Ceilirxy
Total 24590 100.0
Latent Cooling Load=3434 Btuh
Overall U-value=0.215 Btuh/ftz-°F
Data entries checked.
2013-Jun-03 17:11:00
wrightSoft Rig ht-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1
...\wstmp\0a7262f6-Od7e-4d9f-a951-07d6bf475d44.rup Calc=MJ8 Front Door faces: N
JIM Right-J® Worksheet Job: Mullins
Entire House Date: 6/3/2013
By: Tropic Heating&Air Condi...
Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CACO52431
1 Room name Entire House First Floor
2 Exposed wall 152.0 ft 152.0 ft
3 Room height 8.0 ft 8.0 ft heat/cool
4 Room dimensions 1.0 x 1408.0 ft
5 Room area 1408.0 ftp 1408.0 ft'
Ty I Construction U-value Or I HTM I Area (ft') I Load I Area (ftp) I Load
number (Btuh/ftp-°F) (Btuh/ftT) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 yl 12B-Osw 0.097 n 3.36 2.61 288 255 855) 665 288 255 855 665
I- -G 1 D-c2om 0.870 n 30.10 20.96 33 0 1003 699 33 0 1003 699
V) 12B-Osw 0.097 e 3.36 2.61 320 283 948 737 320 283 948 737
r O 1 D-c2om 0.870 e 30.10 56.30 38 0 1129 2111 38 0 1129 2111
11 yJ 12B-Osw 0.097 s 3.36 2.61 288 223 747 581 288 223 747 581
IL—DC, 1D-c2om 0.870 s 30.10 24.98 33 0 1003 833 33 0 1003 833
11 DO 0.390 s 13.49 11.43 32 32 433 367 32 32 433 367
W 12B-0sw 0.097 w 3.36 2.61 320 283 951 739 320 283 951 739
I—G 1 D-c2om 0.870 w 30.10 56.30 37 0 1104 2064 37 0 1104 2064
C 16B-1 lad 0.081 2.80 4.28 1408 1408 3946 6022 1408 1408 3946 6022
F 19A-OcvtD 0.368 4.14 1.95 1408 1408 5834 2748 1408 1408 5834 2748
61 c)AED excursion 01 1 1 0
Envelope loss/gain 1 17953 17565 1 17953 17565
12 a) Infiltration 3210 773 3210 773
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 3 690 3 690
Appliances/other 1200 1200
Subtotal(lines 6 to 13) 21163 20228 21163 20228
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution C 0 3 0
21163
14 Subtotal 21163 20228 20228
15 Duct loads 23% 22% 4843 4362 23% 22% 4843 4362
1 Total room load 1 I 1 260061 245901 1 1 260061 245901
Air required(cfm) 1115 1115 1115 1115
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
�,_ 2013-Jun-03 17:11:00
_ -44- wrightsoft Right-Suite(D Universal 2012 12.1.07 Right J®Mobile Page 1
'�" ...\wstmpt0a7262f6-Od7e-4d9fa951-07d6bf475d44.rup Calc=MJ8 Front Door faces: N
Comrlonen# Constructions Job: Mullins
r Date: 6/3/2013
Entire House By: Tropic Heating&Air C...
Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CA0052431
Projectf •
For: Susan Mullins, Tropic Heating&AirConditioning,lnc.
348 8th St.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75
Elevation: 43 ft Design TD(°F) 35 16
Latitude: 30°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8
Dry bulb(°F) 35 91 Infiltration:
Dailyrange(°F) - 17 ( M ) Method Simplified
Wet bulb(°F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain
ft' 2tuhA1'-`F ft'-'F/Ruh Btuh NO Btuh Btuh/ft' Btuh
Walls
12B-Osw: Frm wall,vnl ext, r-11 cav ins, 1/2"gypsum board int n 255 0.097 11.0 3.36 855 2.61 665
fnsh,2"x4"wood frm e 283 0.097 11.0 3.36 948 2.61 737
S 223 0.097 11.0 3.36 747 2.61 581
w 283 0.097 11.0 3.36 951 2.61 739
all 1043 0.097 11.0 3.36 3501 2.61 2722
Partitions
(none)
Windows
1D-c2om:2 glazing,clr outr,air gas,mtl no brk frm mat,clr innr, 1/4" n 33 0.870 0 30.1 1003 21.0 699
gap, 1/8"thk;50% blinds 45°,light;50%outdoor insect screen e 38 0.870 0 30.1 1129 56.3 2111
S 33 0.870 0 30.1 1003 25.0 833
w 37 0.870 0 30.1 1104 56.3 2064
all 141 0.870 0 30.1 4239 40.5 5707
Doors
11 DO:Door,wd sc type s 32 0.390 0 13.5 433 11.4 367
Ceilings
16B-1 lad:Attic ceiling, asphalt shingles roof mat,r-11 cell ins, 1/2" 1408 0.081 11.0 2.80 3946 4.28 6022
gypsum board int fnsh
Floors
19A-Ocvtp: Fir floor,wd fir, T'thkns,tile fir fnsh, leaky crwl ovr 1408 0.368 0 4.14 5834 1.95 2748
2013-Jun-03 17:11:00
Wright5Oft Right-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1
AC ...lwstmp\Oa7262f6-Od7e-4d9fa951-07d6bf475d44.rup Calc=MJ8 Front Door faces: N
AED Assessment Job: Mullins
t Date: 6/3/2013
Entire House By: Tropic Heating&Air C...
Tropic Heating & Air Conditioning, Inc.
750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431
Project • •
For: Susan Mullins, Tropic Heating&AirConditioning,lnc.
348 8th St.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75
Elevation: 43 ft Design TD(°F) 35 16
Latitude: 30°N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8
Dry bulb(°F) 35 91 Infiltration:
Dallyrange (°F) - 17 ( M )
Wet bulb(°F) - 77
Wind speed (mph) 15.0 7.5
Test for • - • Exposure-Divers
HourlyGlazing Load
8,00
7,00
6,00
5,00
4,00
3,00
2,00
1 ,00
[It
9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
Hourly A,erage 4ED lin it
Maximum hourly glazing load exceeds average by 20.1%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-Jun-03 17:11:00
WrlghtSOf# Right-Suite®Universal 2012 12.1.07 Right J®Mobile Pagel
A-_ _.\wstmp\Oa7262f6-Od7e-4d9f-a951-07d6bf475d44.rup Calc=MJ8 Front Door faces: N