Loading...
112 Poinsettia St 2013 HVACCITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 13-00002774 Date 6/03/13 Property Address . . . . . . 112 POINSETTIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------ Application desc 1 cu 1 ahu 2 tons -------------------------------------------------------------- Owner Contractor ------------------------ - ----------------------- SMITH LORRAINE N DONOVAN HEATING & AIR 112 POINSETTIA ST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322334018 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 91.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 11/30/13 --------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 ------------------------------------------------------- Fee summary Charged Paid Credited Due ---------- ---------- ----------------- Permit Fee Total ---------- 91.00 ---------- 91.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 95.00 95.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 10B ADDRESS: MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 J\, a '1�z1 PROJECT VALUE $ 7-900 ARI PERMIT # 5-7 %UJB REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Condenser Only Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit f Heat: Unit Quantity I BTU's Per Unit 000 Seer Rating Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) TIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets # Vented Wall Furnaces Pumps Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name L of -C t i rE Mechanical Company ,J0t dVNr� ;o. Address: �� 1 s C2t-1- ,icense Holder (Print): , 11 a ri Phone Number Zy I -yo2 ? A1,/, Office Phone ZY / 3 KFax lyl 37 m k5 S City Votarized Signature of License lder Notary Pubic State or Fbrida efore me this � day of ETV Timothy Lee HughesMy Commission EE 188278 i nature of Notar PublicExpires 0410 312 0 1 8 g y —� State —a Zip �Q / State Certification/Registration # (_ 'A J! X 20 +`+ wrightsoft Project Summary Entire House Donovan Heat & Air Job: Date: May 24, 2013 By: Aaron Thacker 315 6th Ave S, Jacksonville Beach, FL 32250 Phone: 904-241-3785 Fax: 904-241-3745 Email: aaron@donovanac.com Web: www.DonovanAC.com Project Information For: Lorraine Smith, Donovan heat and air 112 Poinsettia St., Jacksonville, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Inside db 70 'F Design TD 31 'F Heating Summary 50 % Moisture difference Structure 11282 Btuh Ducts 3342 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 14624 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heating Coolin Area (ft2) 1324 132 Volume (ft') 11916 11916 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 89 46 Heating Equipment Summary Make Tempstar Trade 13 SEER N SERIES R410A HP Model N4H330A(G)KB` AHRI ref no3464356 Efficiency 7.8 HSPF Heating input Heating output 29800 Btuh @ 47°F Temperature rise 27 'F Actual air flow 993 cfm Air flow factor 0.068 cfm/Btuh Static pressure 0 in H2O Space thermostat Outside db 95 °F Inside db 75 'F Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Sensible Cooling Equipment Load Sizing Structure 15262 Btuh Ducts 4740 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Equipment sensible load 20002 Btuh Latent Cooling Equipment Load Sizing Structure 2253 Btuh Ducts 1011 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 3264 Btuh Equipment total load 23266 Btuh Req. total capacity at 0.70 SHR 2.4 ton Cooling Equipment Summary Make Tempstar Trade 13 SEER N SERIES R410A HP Cond N4H330A(G)KB-Coil 4** FE --7 5 �� AHRI ref n / Efficiency 11. EER, 14 SEER Sensible cooling 20860 Btuh Latent cooling 8940 Btuh Total cooling 29800 Btuh Actual air flow 993 cfm Air flow factor 0.050 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013 -May -31 10:12:46 wrightsoft Right -Suite® Universal 8.0.24 RSU05995 Page 1 ACCP, C:\Users\Owner\Documenls\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc = MJ8 Front Door faces: S ti9i CERTIFIEDTM www.ahridirectory.org Certificate of Product Rati AHRI Certified Reference Number: 5782014 Date: 6/3/2013 Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source Outdoor Unit Model Number: N4H330A(G)KF1 Indoor Unit Model Number: FEA4X30**A* Manufacturer: TEMPSTAR Trade/Brand name: 13 SEER N SERIES R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 30000 EER Rating (Cooling): 11.20 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 29400 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh) @ 17 F: 17600 Ratings followed by an asterisk (') indicate a voluntary rerate of previously published data, unless accompanied with a WAS, which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized atteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or in part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, "CO Air -Conditioning, Heating, click on "Verify Certificate" link and enterthe AHRI Certified Reference Number and the date on �..0'' and Refrigeration Institute which the certificate was issued, which is listed above, and the Certificate No., which is listed below. ©2013 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130147494310120420