Loading...
1530 Selva Marina Dr 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 r Application Number . . . . . 13-00002819 Date 6/06/13 Property Address . . . . . . 1530 SELVA MARINA DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MOFFITT, JOHN TROPIC HEATING & AIR 1530 SELVA MARINA DR. 750 MAYPORT RD ATLANTIC BEACH FL 322335614 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . - Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . - 12/03/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. &5/13 MECHANICAL PER Ainh APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: lmr, *N�aN a —PERMIT# PROJECT VALUE '<44 0 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# V47 Air Conditioning: Unit Quantity Tons Per Unit 3 REQUIRED Heat: Unit Quantity BTU's Per Unit 34-6;on02_.A1v Seer Rating 15--n, Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Purrips # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that 1 have read this application and know the same tobe true and correct. All provisions of laws and ordinances governing this work-will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company I Office PhoneN Faa( Co. Address: city State K_zip License Holder(Print State Certification/Registration# Cp Notarized Signature of License Holder KAREN E.PANTFOEDER Sworn and sub7scribe�before me this yof 20-a- NOTARY PUBLIC STATE OF FLORIDA Signature of Notary Publ� Comm#EE064448 Expires 3/4/2015 212 abmftlank This combination qualifies for a Federal Energy A&1JJ*J Eff iciency Tax Credit when placed in service CERTIFIED.1m, between Feb 17, 2009 and Dec 31, 2013. Pro- o. AHRI Certified Reference Number: 4843467 Date� 616f2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 215BNA036***+* Indoor Unit Model Number: FX4DN(B,F)037 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS TradelBrand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING S Y ST I-M S -Source Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: in Cooling Capacity (Btuh): 34800 EER Rating(Cool ing): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(l3tuh) @ 47 F: 34600* Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) Ca 17 R 21400 Ratings foilov,,ed by an askerizs*klwdi Late a L4nle-,s acccvnparijed nth a%A.' mich indicates an inwuntary rerde. DISCLAWER osesor guafantecs as to,and Issurnesnovemsponsibility for, AHRI does not endorse the product(s)fisted on this(�ertilicateandrnakes 110 FeWesenUtiff'S,%NOrral the product(s)listed tthe use oi peirf,3iTjwneetwlhf--PoodL§Lt(,,i),orthe W�­ 1­ unauthl)rized altewation o(data listed on this Ceft f1cdtL-Celliftd ratings are v aid only for rnodels arid configui-atiom ii-sed in the dit m(oly at �`;�001Yofg- TE RMS AND CONDITIONS Once Pu9x z 'CeMii�,at_stiall twitir be use�d for individual,pti sGn&I and uoi ifidential te(PR This CEslificate and its cortertS a,eproplietary products 4AHPI,This ed 4 indfW contents of this TtW_1 estitiratem%ay nat,in wx)le oi in part be Feproduced tort,or franoex of by anyrroLmnsi,miceft for ttle user's individual,pel-sonal and conficlential reference- a CERTIFICATE VERIFICATION yi�le inforiTiation for thernodel c iterl on this cCr`tifk&te can beventiedat "Imp Air--C-andiltlinning2 He�dtinj, clickon" --,f,;r-Fzti frat F,link and edff the AH RI Certified peference Hisrher and the date on 41ii"W ME Ad c3nd PefriQsrafion Institute vMich the Certificate vms lssuetj.v4i'lett is J�OeA aboue.and t'ne certit-rateno.,vMch is listed Wow e2013 Air-Conditioning,�-Ijeating,and Pefrigerati011 1�"'Stlt'JtO CERTIFICATE NO.: 13015001201919_3622 fg , - I - Job: Moffitt )roject Summary Date: 6/6QO13 Entire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 750Mayport Rd,Alantic Beach,FL 32233Phom:904-241-1788 Fax 9D4-241-2172 Email:Tropicac@msn.cc)m License CAC052431 Project Information For: J ohn M off itt,Tro pic H e ati ng &Ai rCond iti on ing,l n c. 15 30 Se Iva M ari na Dr.,Atla nti c Be ach, FL 32 233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Notes: Design Information Mather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 *F Inside db 70 'F Inside db 75 'F Design TD 35 *F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29008 Btuh Structure 19797 Btu h Ducts 6305 Btub Ducts 7000 Btuh Centra I vent(0 cf m) 0 Btu h Central I vent(0 cf m) 0 Btu h Humidification 0 Btu h Blower 0 Btu h Piping 0 Btu h Equipment load 35393 Btu h Use manufacturer's data y Ratelswing multiplier 1.00 Infiltration Equipment sensible load 25797 Btu h M eth od Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2673 Btu h Ducts 1886 Btu h Heating Cooling Centra I vent(0 cf m) 0 Btu h Are a(ft2) 2064 2064 Equipment latent load 4558 Btu h Vo I ume(W) 16512 16512 Air changes�hour 0.41 0.21 Equipment total load 30355 Btu h Eq uiv.AV F(cfm) 113 58 Req.total capacity at 0-70 SHR 3.1 ton Heating Equipment Summary Cooling Equipment Summary M ake n/a M ake Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Eff iciency n1a Eff icien cy 0 SEER Heating input 0 M Btuh Sensible cooling 0 Btu h Heating output 0 Btu h Latent cooling 0 Btu h Temperature rise 0 'F Total cooling 0 Btu h Actua I air f low 1085 cfm Actual airflow 1085 cfm Air flow factor 0.031 cf m/Btu h Air flow factor 0-042 cfrrVBtuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J Oth Ed. 201 3-Jun-06 06:51:59 wrigi-ttsoft R ig ht-Su it e@ U ni v ersal 2012 12-1.07 R ight J C9 Mo bile Pagel ...kvchp�3bb723fO-4b2447e5-8o4e-fO436197o4Ob.tup Calc=MJ8 Front Door faces: E Job: Moffitt ornponent Constructions Date: 6/62013 Entire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 75OMayport Rd,,Marilic Beach,FL 32233 Phonei 904-241-1788 Fax 904-241-2172 Email:Tropicac@msn.com Licensa CAC052431 Project Information For: John M off itt,Tropic Heating &AirConditioning,lnc. 1530 Selva Marina Dr.,Atlantic Beach, FIL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig. FL, US Indoor temperature (*F) 70 75 Elevation: 43 ft Design TD(*F) 35 16 Latitude� 30'N Relative humidity 30 50 Outdoor: Heating Cooling M oistu re d iff ere nce(g r/lb) 8.4 52-8 Dry bul b('F) 35 91 Infiltration: Dailyrange(*F) - 17 M M eth od Simplified V\k�t bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 75 Fireplaces 0 Or Area LI-vallue Instill R Htg HTM Loss CIg HTM Gain Construction descriptions t. 8tdile-T Ir-*FA" Btkb Ir etuh Obih le 9tuh Wafls 12B-Osw:Frnn wall,vnl ext,r-1 1 cav ins,112"gypsum board int n 642 0-097 11.0 3.36 2156 2.61 1676 fnsh,2"x4"wood frm e 439 0.097 11.0 3.36 1474 2.61 1146 s 610 0.097 11.0 3.36 2048 2.61 1592 w 439 0.097 11.0 3.36 1474 2.61 1146 all 2131 0.097 11.0 3-36 7162 2.61 5560 Partitions (none) Windows 1 D-c2om:2 glazing,clr outr,air gas,rrdl no brk frm mat,cIr innr,1/4" n 62 0.870 0 30.1 1856 21.0 1293 ga p.1k3"thk;50%blinds 45*,light;50%outdoor inse ct screen e 41 0.870 0 30-1 1229 56.3 2299 s 62 0.870 0 30.1 1856 26.0 1540 w 41 0.870 0 30-1 1229 56.3 2299 all 205 0.870 0 30.1 6171 36.2 7431 Doors s 32 0.390 0 13.5 433 11-4 367 11 DO:Door,wd sc type Ceilings 1613-30a d:Attic ceilin g,asp halt shingles roof mat,r-30 ceil ins,112" 1488 0.032 30.0 1.11 1648 1.69 2514 gypsum board intfnsh Floors 22A-cph:Bg f loor,he av y damp soil,on gra cle d epth,carpet f Ir f nsh 200 1.368 0 47-0 9397 0 0 2013-jun-06 06.7-5200 + vv rightSOft Right-Sute@ u riversal 2012 12.1.07 Right J@ Mobile Pagel ...Wwh p�3bb72310.4b24-47e5-8o4e-10436197o4Ob.rup Calc=MJ 8 F ront Door faces: E Job: Moffitt Right J@ Mobile Report [)ate: 6/62013 Entire House By: Tropic Heating&Air C... % Tropic Heating &Air Conditioning, Inc. 75OMaypott Rd,AM artic Beach,FL32233 Phone:904-2414788 Fax 9D4-241-2172 Email:Tropicac@MSn.0Dm License CAC052431 Project Information For John M off itt,Tropic Heating &AirConditi on ing,Inc. 1530 Se Iva Marina Dr.,Atlantic Beach, F-L 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com -Design Conditions Location: Indoor: Hettirs Cooling Jacksonville/Craig, FL, US Indoor temperature (*F) 70 75 Elevation: 43 ft Design TD ff) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.0 Dry bul b(*F) 35 91 Infiltration: Dailyrange('F) - 17 ( M M eth od Simplified Wet bulb('F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Heating_ Component Btu h fif Btu h % of load Walls 3.4 7152 20.2 PLds Glazing 30.1 6171 17.4 Doors 13.5 433 1-2 Ceilings 1.1 1648 4.7 Irilirdion Floors 6.3 9397 26.6 Infiltration 10 4288 12.1 Claorg Ducts 6305 17.0 Piping 0 0 Humidification 0 a cdFings IFICUS Ventilation 0 0 Adjustments 0 Total 35393, Component BtuhN Btu h % of load Walls 2.6 5560 21.6 rterrEI Oks Glazing 36.2 7431 28�0 \Ad] Doors 11 A 367 1.4 Ceilings 1.7 2514 9-7 Floors 0 0 0 __-Ducts Infiltration 0.4 1035 4.0 Ducts 7000 27.1 0 Ventilation Internal gains 1890 7.3 �_l rf iltrzton Blower 0 0 Glazing L �\ Adjustments 0 (blirgs Total 1 25797 , 100. Qher Late nt Co ol ing Lo ad 4 558 Btu h Overall U-va lu e=0.134 Btuh/ft22F Data entries checked. 2013-Jun-06 06:51 59 + wri43ht,40ft Right-suite@ u niversal 2012 12.1.07 Right J@ Mohle Pagel r faces: E ..Avdm p�3bb7231OAb2447e5-8o4e-10436G7o4Ob.rup Calc=MJ8 F ront Doo Job: Moffitt Dight- I®RW-%jrk-"ee+ Date: &#3,20113 NXI -%# _X I L Entire House By: Tropic Heating&Air Condi... Tropic Heating &Air Conditioning, Inc. 7501%4a�.port Rd, ManticBeach,FL 32233 Phone 904-241�1788 Fa)c 9D4-241-2172 Email:Tropicac@rnsn.corn License CAC052431 1 Room name Entire House First Floor 2 lzpo-_�Td val 1 296 JD ft 200.0 ft 8.0 It 8.0 ft hea+Jcool Room height 1.0 x 1488.0 ft Poem dirn,ensions 1488.0 ft, Rcom area 2064.0 ft' TV C onstuction U "alur Or HTM Area (ft 1) Load Area (ft Load number (Bt jhfftl- F) I or perimeter (ft) (Btuh) or pen meter *(ft) (Btuh) Ruhift H at I Cool 0 r o,,:-- N A1,S H at cool N PS Hat 6 V� 12E)-Osvv 0.097 n 3.36 2B1 704 642 2156 1676 512 465 1559 1212 1 D-c2om 0.870 n 30.10 20.96 62 0 1856 1293 48 0 1430 996 1 2B-0 0.097 e 3.36 2.61 480 439 1474 1146 288 261 8_?� 682 I D-,2s,wm 0 8 70 e 3010 5630 41 0 1229 2299 27 0 803 1501 1 1 VL 12151-0sw 0.097 s 3.36 2.61 704 610 2048 1592 512 432 1451 1128 6-? 0 1856 1540 48 0 1430 1187 1 D-c2om 0.870 s 30.10 24.9B 11D0 0.39D s 13.49 11 A3 32 32 433 367 32 32 433 367 2B-Osvv 0.097 w 3.36 2.61 480 4,19 1474 1146 288 261 877 682 'L.c; 11 D-c2om 0.870 w 30.10 56.-T 41 0 1229 2299 27 0 803 1501 C 168-30ad 0.032 1.11 1.69 1488 1488 1648 2514 912 912 1010 1541 F 22A-mh 131-8 46�99 0.00 1488 200 9397 0 1488 200 9397 0 1 - I — I - I 1 1 :61 c)AED excursion 01 01 Envelope lossigain 2APFIF]1 1587221 20070 1 10797 1 4 1035 2897 691 j 12 a) Infiltration 0 0 0 b) Room Ventilation 13 Internal gaina Occupants @ 230 6qO 690 AppljanaLs�other 1100 1200 Subtr-tal(li nes 6 to 13) 3 18797 13386 0 0 Less e)lernal load 0 0 0 0 Lesstranster 0 0 0 R edi sth buti-or. 29018 18797 22967 133061- 4 Subtotal I 1 01 2 2 cX:, 2.­.'�, J7c,'(j E-305 7000 ,7% 4978 4985 5 Duct load, 5 7 W? -17.C144 18371 Total room load 1085 1061 772 A�r requv�d(cfffi) Calculations approved bV ACCA to nneet all requirements of Manual J Gth Ed� 2013-Jun-06 06 51:59 "n �fr Right-SufteC,,Uriversal20l2l2.1.07 Right J�Dtvlobile Page 1 .,.�%fctrnp'Obb723fg-4L)24-47e��8o4e-fO436197o4Ob.rup Calc=MJ8 Front Door faces: E Right-J OP Worksheet Job: MOM Date: 6.ffi.2013 Entire House By: Tropic Heating&Air Condi... Tropic Heating &Air Conditioning, Inc. Rd,.Af,,rtvc Beadi,FL 32233 Phone:904-241-1788 Fa)c 904-241-2172 Emal Troocac@,rnsn.corn License CAC052431 Seco d Floor 1 Room name ,n 0 ft E)qoosed\-�all Poom height 8.0 ft heaUccol Room dimensions 24.0 x 24.0 ft 576.0 ft2 Room area Ty Constructi n HTM Nea (ft') Load .4 eq Liad number Pt ul-ift-,F (8t uhf ft 1) or perimeter (ft) (Btuh) or perimeter IHeat t ross NJPS H�C Gl-sS t-I-P I:' H Fat Cuil 178 6 v 128-Osvv 0097 n 3.36 2.61 192 1597 464 L-G 1 D-c2om 0.870 n 30.10 20.96 14 0 426 297 12B-Osvv 0.0 97 e 3.36 2.61 192 178 597 464 VL—G 1 D-c2orn 0.870 e 30.10 56.3D 14 0 426 798 1 1 VL 12B-Osvv 0.097 s 3.36 2.61 192 178 597 464 I D-c2orri 0.870 s 30.10 24.9B 14 0 426 354 11 DO 0.390 s 13.49 11.43 0 0 0 0 12B-Osw 0.097 w 3.36 2.611 192 178 597 464 T—G D-c2orn 0.870 w 30.10 56.30 14 0 426 798 1 576 638 973 C 166-30ad 0.032 1.11 1.69 576 0 0 0 F 22A-wh 1.3-% 46.99 ODO 0 1 61 c)AED e)cursion Envelope lo.--JrAain 4731 5075, 13911 12 a) Infifttation 0 0 1 b.) Room ventilation 13 Internal crain-- Occupants @ 0 0 Appliancesiother Subtctal(1i nes 6 to 13) 1 61 0 0 Less e.xternal I oad 0 0 Lesstransfer 0 0 Redi stri Wion 6122 5411 4 Subtotal 1 51 D Lut loads 1327 2015 7448 742� Total room load 228, 312 Av required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 201 3-Jun-06 06:51.59 Page 2 Rig�it-Sufte@Uriversal2Ol2l2.1.07 RigM J@Mobile ...k%,,stnp�3bLi;23fO-4b24A7e'-8o4e-fO436G7c4Ob.tup Calc=MJ8 Front Door faces: E Job: Moffitt AE-D Assessment Date: W6.2013 Entire House By: Tropic Heating&Air C... Tropic Heating &Air Conditioning, Inc. 75OMa�portRci,Atartic[3eacb,FL3�12,33Phore.904-241-1788 Fax 9D4-241-2172 Email�Tropc�ac@msn.oDmLicemeCAC052431 Project Information For: John M off itt,Tropic Heating &AirConditioning,Inc. 1530 Se Iva Marina Dr.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Emai[Trop icac@msn-co m Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US I nd oo r te mp eratu re (*F) 70 75 Elevation: 43 ft Design TD(*F) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling M oistu re d iff ere nce(g r/lb) 8.4 52-8 Dry bul b(*F) 35 91 Infiltration: Dailyrange(*F) - 17 ( M Wet bulb('F) 77 Wind speed(mph) I ri C I 'a- 0 ad NUU11y U/ 1 1-11-Ig LU 11,00G 1 0,00G 9,00c- 8,00c- 7,00 6,00 5,00 4,00 or-1 2,00 1 ,00 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hmtiy Aerage AED 1i nit Maximum hourly glazing load exceeds average by 19.7%. House has adequate exposurediversity(AED), based on AED limit of 30%. AEDexcursion: 0 Etuh 201��-Ajn-06 1-16 52,00 wrightSOft R ig ht-su it e@ U ri v ersal 2012 12.1.07 R iglA J @ Mo bile PacIp.I .J&3� %Yabnp'Gbb72310-4b24-47e5-8o4e-10436A97o4Ob.rup Calc=MJS Frord Door faces� E