5 10th St HVAC 2013 t �S rLl� �J�� � , CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD r� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002837 Date 6/10/13 Property Address . . . . . . 5 10TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 -------------------------------------------------------- Application desc 3TONS, 36K BTU' S, DUCT SYSTEM ------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- CAIRNS SCOTT S & DEBORAH R STAATS A/C & COMM REFRIG, INC 10131 BISHOP LAKE RD W 445 STATE RD 13 N #26 JACKSONVILLE FL 32256 JACKSONVILLE FL 32259 (904) 731-8476 ----------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 119 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/07/13 ---------------------------- Other Fees . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ----------------------------------------------- Fee summary Charged Paid Credited ----Due--- ----- ---------- ---------- Permit Fee Total 119 . 00 119 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 123 . 00 123 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 B ADDRESS' PERMIT# PROJECT VALUE $ -7 �,W AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Quantity BTU's Per Unit Seer Rating Heat: Unit Q �' REQUIRED Duct Systems: Total CFM EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION 04 Air Conditioning: Unit Quantity ..S1.o� Tons Per Unit �� � REOUI D Heat: Unit Quantity BTU's Per Unit=36>,0 U U Seer Rating/QUIRED Duct Systems: Total CFM / [RE PREVENTION Re uires 3 sets of plans) Fire Sprinkler System Quantity ( q (Requires 3 sets of plans) Fire Standpipe Quante' uires 3 sets of plans) Underground Fire Main Value (Requires Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) [RE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators er LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: mnit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified not. The permit does not give autho 'ty to violate the provisions of any other state or local law regulation construction or the performance of construction. Phon Number 57/-5 4 6 3 roperty Owners Name �ZZ.-)'%+ ffice Phon —F ax lechanical Company ;o. Address: rj p 6�o �2 3 /� #Z!5 City state zip tate Certi ication/Registration#�"{�}-CD 2 5 S�/O ,icense Holder (Print): �L �• � Totarized Signature of License Molder r da of 2013 ,;�rP•. JENNIFER WALKER Sworn d subscribed before me this y C MV COMMISSION#Fro?1498 :r EXPIRES:Aptli?.4,20 Signature of Notary Public Pf d; Bonded Thru Notary Pub:c Undenvrilert 0610812013 22:01 9042683670 ENERGY DESIGN INC PAGE 03103 Job: Project Summary Date- 618113 Entire House By: M.Ellis Energy Design Systems,inC. 2x32'lJealheNMd Eetalee Dr W„iacksomAile,FL 32213 Fnone-904263-3070 Fax 904-268-3670 �roa l'eda.Jax ±t l.eomi Project Information For: Cairns Residence,Changeout 5 10th Street,Atlantic Beach, FL Notes: Front of house faces South- Design Inf outh.D- • • a Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 38 T Outside dh 72 OF °F Inside db 72 OF Inside db 72 Design TD 33 OF Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21467 Btuh Structure 22907 Stuh Ducts 2936 Btuh Ducts 4712 Btuh Central vent(22 cfm) 789 Btuh Central vent(22 cfm) 47B Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25195 Btuh Use manufacturer's data ri Rate/swing multiplier 0.97 infiltration Equipment sensible load 27254 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure Ducts 122z�Q Btuh Heating Cooling Central vent(22 cfm) 955 Btuh Area(ft2) 1360 1360 Equipment latent load 4453 Stuh Volume (ftp 10880 10880 Air changeslhour 0.45 0.23 Equipment total load 31707 Btuh Equiv, ATF(cfm) 82 42 Req.total capacity at 0.80 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 213BN(A,W)036---A Colld 21 FS4CNFO 6 )036'"""A AHRI ref 3700149 36 AHRI ref 3700149 Efficiency 8 HSPF Efficiency 11,0 EER, 13 SEWER Heating input Sensible cooling 25500 Btuh Heating output 34000 Btuh Q 47"F Latent cooling 8500 Btuh Temperature rise 27 'F Total coaling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACOA to meet all requirements of Manual J 8th Ed- 2013Jun-08 21:5q:23 -M wrightsoft' Right=s�teM unwersai 2012 12,t,03 RSUf"4,7 Faget ..t Manual J15taaL•AC,Calms Changeout.5 1011n S1.Ail Beh.rup Caie n MJ8 From boo,feces: Page i