Loading...
1839 Ocean Grove Dr 2013 mech CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002833 Date 6/12/13 Property Address . . . . . . 1839 OCEAN GROVE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ------------------------------------------------------------- -------------- Owner Contractor ------------------------ ------------------------ NEVILLE CYNTHIA E AND DONOVAN HEATING & AIR ANDERSON MARK B 315 SIXTH AVENUE SOUTH 1839 OCEAN GROVE DR JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 87 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/09/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 1011 ADDRESS: F) ;9 OU61 y-., P71COVIe- PERMIT# PROJECTVALUE $ q-7ZS; ARI#_3LS 0 1 q 0 REQUIRED Air Handling Equipment Only '� Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit I's Heat: Unit Quantity BTU's Per Unit 18.000 Seer Rating._/5, 3 Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity i Tons Per Unit Heat: Unit Quantity I BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED �IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ZIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Iroperty Owners Name imo,,K 4o8e_,Y50r) Phone Number 755- 2 4 z 0 Aechanical Company D0tj(2iZAtJ dEAK 1� 4-11K —Office Phone 9#VZq/*3_7P_fax '-Y13?Vr -[�a -8 cj, State F1 ziP3212,50 ,o. Address: 3/5' (4— Lve city , ,icense Holder(Print): Wt //1's �On&j 6-vP-1i state certification/Registration# �otarized Signature of License Holder 'k,111 Notary public State of Florift efore me this day of I/nA 20 ON Timothy Lee Hughes ignature of Notary Public My Cormission EE je6278 Expires 04103120is Job: + wrightsoft Project Summary Date: 6/4/13 Entire House By: Brandon Zaharie Donovan Heat & Air 315 6th ave south,Jacksonville Beach, FL 32250 Phone 241-3785 Ernail� brandon@donovanac.com Project Information For: Anderson 1839 Ocean Grove Dr, Atlantic Beach, FL 32233 N ot es: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 'F Inside db 68 'F Inside db 75 'F Design TD 29 'F Design TD 20 'F Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9277 Btuh Structure 10200 Btuh Ducts 1227 Btuh Ducts 1383 Btuh Central vent (28 cfm) 894 Btuh Central vent (28 cfm) 617 Btuh Humidification 0 Btuh Blower 0 Btuh Plpiqg 0 Btuh Equipment load 11397 Btuh Use manufacturer's data in Rate/swing multi lier 1.00 Infiltration Equipment sensibe load 12200 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1434 Btuh Ducts 293 Btuh Heatin Coolin8 Central vent (28 cfm) 1015 Btuh Area (ft 2 4P 48 Equipment latent load 2741 Btuh Volume�ft-) 4320 4320 Air changes/hour 0.89 0.32 Equipment total load 14941 Btuh Equiv.AVF (cfm) 64 23 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model TXH518 Cond TXH518 ARI ref no. 3650190 Coil FXM4X18 ARI ref no. 3650190 Efficiency 8.5 HSPF Efficiency 15.3 SEER Heating input Sensible cooling 10779 Btuh Heating output 15323 Btuh @ 47'F Latent cooling 4620 Btuh Temperature rise 27 'F Total cooling 15399 Btuh Actual air flow 513 cfm Actual air flow 513 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.82 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -46- Right-SuiteG Universal 7.1.01 RSU05996 2013-Jun-04 171157 le& C:\Users\Sales\Documents\Wrightsoft HVAC\1.5 TON.rup Calc=MJ8 Orientation=N Page 1 This combination qualifies for a Federal Energ y Efficiency Tax Credit when placed in service NUILA CERTIFIEDTM between Feb 17, 2009 and Dec 31, 2013. ww w.a hri d ire c to ry.a rg Certificate of Product Ratings AHRI Certified Reference Number: 3650190 Date: 6/12/2013 f Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: TXH518GKA* Indoor Unit Model Number: FXM4Xl8**A* Manufacturer: TEMPSTAR Trade/Brand name: SMARTCOMFORT TX 5500 R410A HP Manufacturer responsible for the rating of this system combination is TEMPSTAR Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 17800 EER Rating (Cooling): 12.60 SEER Rating (Cooling): 15.25 Heating Capacity(Btuh)@ 47 F: 17800 Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh)@ 17 F: 10.700 Ratings followed by an asterisk indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out ofthe use or performance of the product(s),or the unauthorized alteration of data listed on this Certilficate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, it "Imp, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on No ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130155163723679350