377 8th St - HVAC 2013 % J%�JN ,
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002893 Date 6/17/13
Property Address . . . . . . 377 8TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BARKSDALE SARAH K & KEITH P. AIR EXCELLENCE INSTALLATION
936 WILD CHERRY LANE AND SERVICE INC
FORT COLLINS CO 80S21 3813 BALD EAGLE LA
JACKSONVILLE FL 32257
(904) 923-4967
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/14/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC REACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: C c6 — `24 - PERmrr
PROJECT VALUE $ 91 GO , ARI# 00 14 REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity i Tons Per Unit 3 ( 3. 0
Heat: Unit Quantity BTU's Per Unit'U,joa Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating_
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Reffigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name 0"1154-K 60"I'Aj PhoneNumber -:�1-7 -17(-S
Mechanical Company !��vrce- Amer-'t-q Office Phone TT3 VOk Fax
Co. Address: -e;+ City -TAA State 11- Zip 3"-5
License Holder(Print): State Certification/Registration# 4,-'A ent-414,�?L<,
Notarized ature of License Ho r
fA ORTENCA(WINI
,6 r6 Notary Public,State of Florida efore me this day of 20J-3
J-u ii Commission#EE 49709
Mycomm.9xpires Dec.16,20114ignature of Notary Public
CERTIFIEDT.
www.ahridirectory.org j�
Certificate of Product Ratings
AHRI Certified Reference Number: 3700149 Date: 6/17/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 213BN(A,W)036****A
Indoor Unit Model Number: FB4CNF036
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY LINE PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh)� 34000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 34000
Region IV HSPF Rating (Heating): 8.00
Heating Capacity(Btuh) @ 17 F: 21400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no represerrtations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at Avw.ahridirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Cenificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in paM be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The info...ia on for the model cited on this certificate can be verified at v�kwahtidirectory.org,
,,OW Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No.,which is listed below.
Q2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130159475411012216
Right J@ Mobile Report Job:
Date: 6/17/2013
Entire House By:
AL
Project Information
For: Conrad
377 8th st, Atlantic beach, FL 32233
Phone: 904-307-1765
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature ('F) 70 75
Elevation: 43 ft Design TD ('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Dailyrange ('F) - 17 ( M Method Simplified
�Akt bulb('F) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btu h/ft2 Btuh % of load
Walls 7.5 10182 38.9 "Itraci-i
Glazing 19.7 4914 18.8
Doors 13.5 283 1.1 VVIS
Ceilings 1.7 2797 10.7 Him
Floors 2.7 4453 17.0
Infiltration 2.2 3574 13.6
Ducts 0 0
Piping 0 0 Calirgs
0 It
Humidification 0 0 Ctff
Ventilation 0 0 GmM
Adjustments 0
Total 1 26203 , 100.01
ME Me
Component Btu h/ft2 Btuh %of load
Walls 3.5 4738 20.0 Interrd Gans
Glazing 40.2 10022 42.3 V\tfls Irtiltratian
Doors 11.4 240 1.0 Flocrs
Ceilings 2.6 4269 18.0
Floors 1.0 1647 7.0
Infiltration 0.5 886 3.7
Ducts 0 0
Ventilation 0 0
Internal gains 1890 8.0
Blower 0 0 Cthw
Adjustments 0 Ga�irg
Total 23692 100.0
Latent Cooling Load 2375 Btuh
Overall U-\a lue =0.133 Btuh/fF-'F
Data entries checked.
2013-Jun-17 04:05:24
1:t-m + wrightSOft Right-SuiteO universal 2012 12.1.07 Right J@ Mobile Page 1
,C-C4, .,\wstmp\eOba4efc-eca7-426e-9146-a5O6dce87e5c.rup Calc=MJ8 Front Door faces: s
Job:
Project Summary Bob: 611712OU
TA4W Entire House By:
AL
Project Information
For: Conrad
377 8th st, Atlantic beach, FL 32233
Phone: 904-307-1765
Notes:
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26203 Btuh Structure 23692 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 26203 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 23692 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2375 Btuh
Ducts 0 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft� 1650 1650 Equipment latent load 2375 Btuh
Volume (fP) 14850 14850
Air changes/hour 0.38 0.20 Equipment total load 26068 Btuh
Equiv. AVF (cfm) 94 50 Req.total capacity at 0.70 SHR 2.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficiency 0 SEER
Heating input 0 MBtuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 oF Total cooling 0 Btuh
Actual air flow 1079 cfm Actual air flow 1079 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Jun-17 04:05:24
,Zt: + vvrightSoft Right-Suite@ Universal 2012 12.1.07 Right J@ Mobile Page 1
...kwstmp\eOba4efc-eca7-426e-9146-a5O6dce87e5c.rup caic=MJ8 Front Door faces: S
Right-JO Worksheet Job:
Entire House Date: 6117/2013
By:
AL
1 Room name Entire House First Floor
2 Exposed wall 180�13 ft 18&0 ft
3 Room height 9�0 ft d 9�0 ft heat/cool
4 Room dimensions 1.0 x 1650.0 ft
5 Room area 1650�O ft2 1650.0 ft2
I I I I I I
Ty Construction U-value 0, FITM Area (w) Load Area (w) Load
number (Bt uh/ft2_ F) (8t uh/f t2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Vr__G 14E-2ow 0.218 n 7.54 3.51 450 376 2835 1319 450 376 2835 1319
1 D-c2 0.570 n 19.72 20.91 74 0 1463 1 551 74 0 1463 1 551
14E-2 0.218 e 7.54 3.51 360 306 2307 1073 360 306 2307 1073
1--G 1 D-c2ow 0.570 e 19.72 63.01 54 0 1068 3413 54 0 1068 3413
11 14E-2 0.218 s 7.54 3.51 450 383 2885 1342 450 383 2885 1342
VL-G 1 D-c2ow 0.570 s 19.72 25.16 68 0 1331 1698 68 0 1331 1698
14E-2 0.218 w 7.54 3.51 360 286 2155 1003 360 286 2155 1003
1 D-c2ow 0.570 w 19.72 6101 53 0 1052 3360 53 0 1052 3360
D 1 1DO 0,390 w 13.49 11.43 21 21 283 240 21 21 283 240
C 16B-19ad 0.049 1�70 2.59 1650 1650 2797 4269 1650 1650 2797 4269
F 20P-1 lt O�078 2.70 1.00 1650 1650 4453 1647 1650 1650 4453 1647
61 c)AED excursion 01
Envelope loss/gain 1 226291 209161 1 1 226291 20
12 a) Infiltration 3574 886 3574 886
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 3 690 3 690
Appliances/other 1200 1200
Subtotal(lines 6 to 13) 26203 23692 26203 23692
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 26203 23692 26203 23692
15 Duct loads 0% 0% 0 0 _0% 0% 0 0
1 Total room load 262031 236921 1 262031 23692
Air required(cfm) 1079 1079 1079 '079
Calculations ngroved by ACCA to meet all reguirements of Manual J 8th Ed.
vvriid3"t!.c3ft 2013-Jun-17 04:05:24
Right-Suite@ Universal 2012 12.1,07 Right J(9)Mobile Page 1
\wstmp\eOba4efc-eca7-426e-9146-a5O6dce87e5c.rup Calc=MJ8 Front Door faces S
Component Constructions Job:
Daft: W1171=13
7RAM' Entire House
AL
Project Information
For: Conrad
377 8th st,Atlantic beach, FL 32233
Phone:904-307-1765
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature (T) 70 75
Elevation: 43 ft Design TD(T) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8
Dry bulb(*F) 35 91 Infiltration:
Dailyrange(T) - 17 ( M Method Simplified
Wet bulb('F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain
ft2 BWIW-*F ft2-*F/Bb.M Bblhtre Btuh BbhtW Btuh
Walls
14E-2:Blk wall,r-2 ext bd ins,8"thk n 376 0.218 2.0 7.54 2835 3.51 1319
e 306 0.218 2.0 7.54 2307 3.51 1073
S 383 0.218 2.0 7.54 2885 3.51 1342
w 286 0.218 2.0 7.54 2155 3.51 1003
all 1350 0.218 2.0 7.54 10182 3.51 4738
Partitions
(none)
Windows
1 D-c2ow:2 glazing,cir outr,air gas,wd frm mat,dr innr,1/4"gap, n 74 0.570 0 19.7 1463 20.9 1551
1/8"thk e 54 0.570 0 19.7 1068 63.0 3413
S 68 0.570 0 19.7 1331 25.2 1698
w 53 0.570 0 19.7 1052 63.0 3360
all 249 0.570 0 19.7 4914 40.2 10022
Doom
11 DO:Door,wd sc type w 21 0.390 0 13.5 283 11.4 240
Ceilings
1613-1 9ad:Attic ceiling,asphalt shingles roof mat,r-19 ceil ins,1/2" 1650 0.049 19.0 1.70 2797 2.59 4269
gypsum board int fhsh
Floors
20P-1 1 t:Flr floor,wo fir,1"thkns,tile fir fnsh,r-1 1 ext ins,amb ovr 1650 0.078 11.0 2.70 4453 1.00 1647
2013-Jun-17 04:05:24
wrhjhtS0ft Right-Suftes Universal 2012 12.1.07 Right.10 Mobile Page 1
ACCK \wstrnp\eOba4efc-eca7-426e-9146-a5O6dce87e5c.rup Calc=MJ8 Front Door faces: S
Job:
AED Assessment Date: 611 71M 3
4D TANNIF Entire House By:
AL
Project Information
For: Conrad
377 8th st,Atlantic beach, FL 32233
Phone:904-307-1765
Design Conditions.
Location: Indoor: Heating Coolin7
Jacksonville/Craig, FL, US Indoor temperature('F) 70 75
Elevation: 43 ft Design TD(OF) 35 16
Latitude: WON Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference(grAb) 8.4 52.8
Dry bulb(OF) 35 91 Infiltration:
Dailyrange(OF) - 17 ( M
Wetbulb(OF) - 77
Wind speed(mph) 15.0 7.5
Test for Adequate Exposure Diversity
Hourly Glazing Load
14100c-
12700G
10,000
8,00
6,OOC-
4100
2700
01
8 9 10 11 12 13 14 15 16 17 18 19 20
Hour of Day
HoWy - Aerage PEDIinit
Maximum hourly glazing load exceeds average by 18.7%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-Jun-17 04:05:24
k- + wrioghtSOft Right-SuiteO Universal 2012 12.1.07 Right JO Mobile Page 1
\wstmp\eOba4efc-eca7-426e-9146-a5O6dce87e5c.rup Calc=MJ8 Front Door faces: S
N
First Floor
First Floc
Job M Scale: 1 -. 92
Performed for: Page 1
Conrad Right-SuiteOUniversal 2012
377 8th st AL 12.1.07 Right J@Mobile
Atlantic beach,FL 32233 2013-Jun-17 04:05:25
Phone:904-307-1765 ...-eca7-426e-9146-a5O6dce87e5c.rup