Loading...
1839 Ocean Grove Dr 2013 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD !� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002887 Date 6/17/13 Property Address . . . . . . 1839 OCEAN GROVE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 . 5 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ NEVILLE CYNTHIA E AND DONOVAN HEATING & AIR ANDERSON MARK B 315 SIXTH AVENUE SOUTH 1839 OCEAN GROVE DR JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-3785 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/14/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 10B ADDRESS: i sss Oce,-r, G-row- —br PERMIT# PROJECT VALUE $ 5 QO`l ARI# Z 18 REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity_ BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit5 Heat: Unit Quantity / BTU's Per Unit Seer Rating �S•ZS Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners NameMork ilip-YS Or- Phone Number -{'!S5 Z b Zo M Mechanical Company. )n fij oV.b� Office Phone 2 W Fax 2`131 YC ;o. Address: 3�5 C?� q,.e S city i��iX 6 cid, _ State Fl Zip 327-�& .icense Holder(Print): Wf/Iia M State Certification/Registration# oicn 3KV Notarized Signature of License Holder40 06k �✓ Before me this�7 day of ZW-e., 20 i3 =nWh e e Signature of Notary Public a W Project Summa Date: Apr 17,2013 +�+ wrightsoft i Entire House By: donovan heat and air 315 6 th avenue south,jacksonville beach,fl.32250 Phone:904-241-3785 • • • For: MARK ANDERON, DONOVAN HEAT AND AIR 1839 OCEAN GROVE DR., ATLANTIC BEACH, FL 32233 Notes: Desian Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 of Inside db 68 'F Inside db Design TD 29 'F Design TD 2L of Daily range Relative humidity 50 % Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11973 Btuh Structure 16132 Btuh Ducts 3446 Btuh Ducts 5442 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15419 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 22437 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2813 Btuh Fireplaces 1 (Average) Structure Ducts 1394 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft') 805 805 Equipment latent load 4207 Btuh Volume (ft') 7245 7245 Air changes/hour 0.78 0.32 Equipment total load 26645 Btuh Equiv. AVF (cfm) 94 39 Req. total capacity at 0.70 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make TEMPSTAR Make TEMPSTAR Trade TEMPSTAR Trade TEMPSTAR Model TXH530GKA Cond TXH530GKA ARI ref no. 3650218 Coil FXM4X30 ARI ref no. 3650218 Efficiency 8.5 HSPF Efficiency 7.9 EER, 15.3 SEER Heating Input Sensible cooling 20160 Btuh Heating output 19961 Btuh @ 47°F Latent cooling 28640 Btuh 00 Btuh Temperature rise 18 °F Total cooling 1000 cfm Actual air flow 1000 cfm Actual air flow Air flow factor 0.065 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O StaticLoad sens ble heat ratio 0.8ressure 4 in H2O Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wriglitsoft Right-Suite®Universal 7.1.12 RSU05711 2013-Jun-14 15:17:36 ACCP. C:\Documents and Settings\VaioUser\My Documents\Wrightsoft HVAC\Demo\2 T.rup Calc=MJ8 orienta Page 1