1839 Ocean Grove Dr 2013 HVAC CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
!� ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002887 Date 6/17/13
Property Address . . . . . . 1839 OCEAN GROVE DR
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU 2 . 5 TONS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
NEVILLE CYNTHIA E AND DONOVAN HEATING & AIR
ANDERSON MARK B 315 SIXTH AVENUE SOUTH
1839 OCEAN GROVE DR JACKSONVILLE BEACH FL 32250
ATLANTIC BEACH FL 32233 (904) 241-3785
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/14/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
10B ADDRESS: i sss Oce,-r, G-row- —br PERMIT#
PROJECT VALUE $ 5 QO`l ARI# Z 18 REQUIRED
_Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity_ BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit5
Heat: Unit Quantity / BTU's Per Unit Seer Rating �S•ZS
Duct Systems: Total CFM REQUIRED
IRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners NameMork ilip-YS Or- Phone Number -{'!S5 Z b Zo
M
Mechanical Company. )n fij oV.b� Office Phone 2 W Fax 2`131 YC
;o. Address: 3�5 C?� q,.e S city i��iX 6 cid, _ State Fl Zip 327-�&
.icense Holder(Print): Wf/Iia M State Certification/Registration# oicn 3KV
Notarized Signature of License Holder40 06k �✓
Before me this�7 day of ZW-e., 20 i3
=nWh
e
e
Signature of Notary Public
a W
Project Summa Date: Apr 17,2013
+�+ wrightsoft i
Entire House By:
donovan heat and air
315 6 th avenue south,jacksonville beach,fl.32250 Phone:904-241-3785
• • •
For: MARK ANDERON, DONOVAN HEAT AND AIR
1839 OCEAN GROVE DR., ATLANTIC BEACH, FL 32233
Notes:
Desian Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 95 of
Inside db 68 'F Inside db
Design TD 29 'F Design TD 2L of
Daily range
Relative humidity 50 %
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11973 Btuh Structure 16132 Btuh
Ducts 3446 Btuh Ducts 5442 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 15419 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 22437 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2813 Btuh
Fireplaces 1 (Average) Structure
Ducts 1394 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area (ft') 805 805 Equipment latent load 4207 Btuh
Volume (ft') 7245 7245
Air changes/hour 0.78 0.32 Equipment total load 26645 Btuh
Equiv. AVF (cfm) 94 39 Req. total capacity at 0.70 SHR 2.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make TEMPSTAR Make TEMPSTAR
Trade TEMPSTAR Trade TEMPSTAR
Model TXH530GKA Cond TXH530GKA
ARI ref no. 3650218 Coil FXM4X30
ARI ref no. 3650218
Efficiency 8.5 HSPF Efficiency 7.9 EER, 15.3 SEER
Heating Input Sensible cooling 20160 Btuh
Heating output 19961 Btuh @ 47°F Latent cooling 28640 Btuh
00 Btuh
Temperature rise 18 °F Total cooling 1000 cfm
Actual air flow 1000 cfm Actual air flow
Air flow factor 0.065 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O StaticLoad sens ble heat ratio 0.8ressure 4 in H2O
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wriglitsoft Right-Suite®Universal 7.1.12 RSU05711 2013-Jun-14 15:17:36
ACCP. C:\Documents and Settings\VaioUser\My Documents\Wrightsoft HVAC\Demo\2 T.rup Calc=MJ8 orienta Page 1