Loading...
450 Aquatic Dr 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 it Application Number . . . . . 13-00002872 Date 6/14/13 Property Address . . . . . . 4SO AQUATIC DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ VONDERHAAR, RITA ONE HOUR AIR 450 AQUATIC DRIVE 1015 ATLANTIC BLVD #249 ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (904) 222-8482 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/11/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 RIESS: PERmrr# JOB ADD (VL,)04:T Q- PROJECTVALUE $ 415-00, — ARI# 3GS-0 —REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATMG SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 1'1� Heat: Unit Quantity::--E BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts ATU's Gas Piping Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authon, to violate the 7pisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Z, Phone Number A S-L]--16 V 6 OfficePhoneZV3 -7Fax247-55--26 Mechanical Company Q 1/ state zip 72 Z-77 Co. Address:/ V PO�Z 17 klip City&6&9j I License Holder(Print): (,/?,a I ,< S ation/Registration#C4C(Rqy--ao Notarized at Ider GRAHM me this t2O MY COMAISSION#DD 957760 Before E)(pjFjES:Februa 14 2014 goneedThruN aryPublicu, Signature of Notary Pub Project Summary Job: 123503 + wrightsoft Date: 6114/2013 Entire House By: CRAIG EDDY ONE HOUR AIR 1198 MAYPORT RD#1,ATLANTIC BEACH,FL 32233 Phone:904-241-3107 Fax:904-247-5526 License:CAC1814420 Project Information For: RITA VONDERHAAR 450 AQUATIC DR, ATLANTIC BEACH, FL 32233 Phone: 904-654-3646 Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 'F Inside db 75 'F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30546 Btuh Structure 28458 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30546 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28458 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2801 Btuh Ducts 0 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1456 1456 Equipment latent load 2801 Btuh Volume (ft) 11648 11648 Air changes/hour 0.45 0.23 Equipment total load 31259 Btuh Equiv. AVF (cfm) 87 45 Req. total capacity at 0.80 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make GOODMAN Make GOODMAN Trade AMANA DISTINCTIONS Trade AMANA DISTINCTIONS Model GSZ130361 Cond GSZ1 30361 AHRI ref 3850485 Coil AWUF3708 AHRI ref 3850485 Efficiency 0 HSPF Efficiency 13 SEER Heating input Sensible cooling 27200 Btuh Heating output 0 Btu h @ 47'F Latent cooling 6800 Btuh Temperature rise 0 'F Total cooling 34000 Btuh Actual air flow 1296 cfm Actual air flow 1296 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jun-1 4 05 51 33 wriiightSOft Right-Suite@ Universal 2012 12.1.07 Right JO Mobile Page 1 .\wstmp\oef6ea9b-6b3l-4922-8152-079ea29025bc rup Calc=MJ8 Front Door faces E CERTIFIEDT. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3850485 Date: 6/14/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ1 30361 B* Indoor Unit Model Number: AWUF37XX16B* Manufacturer: GOODMAN MANUFACTURING CO., LP. Trade/Brand name: GOODMAN, JANITROL, AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONINC. ND Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Sodrcel Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 34000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 34000 Region IV HSPF-Rating(Heating): 8.00 Heating Capacity(Btuh)@ 17 F: 21000 I ry rerate. Ratings followed by an asterisk indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an invo unta DISCLAIMER sentations,warranties or guarantees as to,and assumes no responsibility forl� AHRI does not endorse the product(s)listed on this Certificate and makes no repre sing out of the use or performance of the product(s),or the the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arl unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS etary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. This Certificate and its contents are propri The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION *I Air-Conditioning,Heating, The infonination for the model cited on this certificate can be verified at www.ahridirectory.org, "IMF, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on On ILI and Refrigeration Institute which the certificate was issued,which is listed above,and the Cerfificate No.,which is listed below. @2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130156950219577850