Loading...
2279 Seminole Rd # 10 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00002842 Date 6/11/13 Property Address . . . . . . 2279 SEMINOLE RD UNIT 010 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu. duct work ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ DRISCOLL, KEVIN NORTHPORT CONSTRUCTION GROUP 2279 SEMINOLE RD # 10 NORTHPORT HGT AND AIR ATLANTIC BEACH FL 32233 1873 EVERLEE RD JACKSONVILLE FL 32216 (907) 731-8248 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 111 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/08/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 111 . 00 111 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 115 . 00 115 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach. FL -322-33 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: C- "/,,V 0 /- C- 910 H10 32233 PERMIT# PROJECT VALUES q, 2 5-(2 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: tl';'nit Quantitv BTU.'s Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION AR14 tl,526 -�2S Air Conditioning: Unit Quantity Tons Per Unit I TO" REQUIRED Heat: Unit Quantity I BIT)"s Per Unit 2 3 0 0 0 Seer Rating J I Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System QuantitN (Requires 3 sets of plans) Fire Standpipe Quantitv (Requires 3 sets of plans) Underground Fire Main Value' ' - (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalaiors ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps 4 Vented Wall Furnaces Refrigerator Condenser BTUs 4 Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: A C- P 1/-9 6 C- .X/S, ryv C W 0 P-t 11crin it become,,void if work does not coin mence within a six month period or work is suspended or abandoned lor six months. I hereby certif*v that I have read this appli cation and knov�the same to be trLic and correct. A I I provis ions of I ax�s and ordinances goNcrining this work .\,i I I be comp I ied with whether specified or not. l'he permit does not give authorit\ to .io late the prov isi on s of any other state or local I a%\ regulation construction or the perl'ormance of construction. Property Owners Name XCV/" /) P-I& - 0 t(, Phone Number Mechanical Company/VOP-TY Pog -r t-16A 7-11V 6 ,9^4 4//Z Office Phone ?3/-22YIFax -73/- 82 �9 Co. Address: ) Z 3 2) 016 R L C-. C /Z 10 City -56CK Sov CC- State E4-zip 1.2 2 License Holder(Print): State Certificatioil,"Re(yistration # .Votarized Signature of License Holder Sworn a subscribed before me this dav of -5 L/ 6' 2016 "Sip. ALMIR HADZIC Signature of Notarx, Public My COMMISSION#EE867035 EXPIRES January 22.2017 F%*rKWN0WySW*0*CIM MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 6"11V 0 0 ^S2 2 3 3 PERMIT PROJECT VALUES 36 0 NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantit\ Tons Per Unit Heat: Ulnit Quantit1% BTUI's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI 4 5 2 .9 60v/9 Air Conditioning: Unit Quantity Fons Per Unit — 1 '/4 70"V REQUIRED S Heat: Unit Quantltl%,' B PerUnit / :� orr Seer Rating 13 Duct Systems. Total CFM REQUIRED I FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Undera ound Fire Main Value' (Requires 3 sets of plans) r I Fire Hose Cabinets Quantit� (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantitv (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Z1- Quantity of Outlets Pumps 4 Vented Wall Furnaces Refrigerator Condenser BTU"s 4' Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: 6 P 1,q C C- (-- A IS 7-11V V C. wo 11crin it become.-;void if work does not coin rnencc �Nithin a six month period or Nkork is suspended or abandoned 11or six months. I hereb�certi I,y that 1 have read this application and knm� the same to be true and correct. All pro,,isions ofla%�s and ordinance,,go-,cming this work v,ill be complied with whether specified or not. Fhe permit does not give authorit\ to ,iolate the provision�ofany other state or local [a%% regulation construction or the perl'ormance ofconstruction. Property Owners Name K-6� Vl" 0 &15 c_0 Phone Number ' ' Mechanical Company fvof-7-H Pol-7- *av0 ,9//VfficePhone'?3/-32V2 Fax '3`11-82Y-9 Co. Address: 1391 6 V 6 Je/-66 /ez CItv-119CK:So,#V111ctC StateF4- ZiP12- 2-141 License Holder (Print): j!5/mi-we Vdl" State Certification,/Reoistration#M U!2,50039' oe_ .Votarized Signature of License Holder V�-1,��—; 2013 Swoman si ibscri bed before me this av of -3 VH6 ALMIR HADZIC SioFnature of NotarN Public M m y y COMMISSION 0 EE867055 E rXP IRES XPIRES January 22,2017 Ao,�S&w*cor" Job: Project Summary Date: 04/23113 1st and 2nd By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(9G4)800-1222 Web:www.LoadCalculations.com Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FIL 32233 Notes: Design Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 oF Outside db 92 *F Inside db 70 *F Inside db 75 *F Design TD 31 'F Design TD 17 *F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16132 Btuh Structure 14383 Btuh Ducts 2037 Btu h Ducts 1891 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18169 Btu h Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 15802 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 1 (Semi-loose) Structure 2485 Btuh Ducts 690 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 1322 1322 Equipment latent load 3175 Btuh Volume(ft) 12777 12777 Air changes/hour 0.61 0.29 Equipment total load 18977 Btuh Equiv.AVF(cfm) 131 61 Req.total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL,AMANA DISTI... Trade GOODMAN, JANITROL,AMANA DISTI... Model GSZ1 30241 B* Cond GSZ1 30241 B* AHRI ref 4526325 Coil AR*F182416C* AHRI ref 4526325 Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 16380 Btuh Heating output 23000 Btuh@47-F Latent cooling 7020 Btuh Temperature rise 27 *F Total cooling 23400 Btuh Actual air flow 780 cfm Actual air flow 780 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.84 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-24 13:14:57 wrightSOft' Right-SuitelD U niversal 2012 12.1.07 RSU1 5431 Page 1 AC(51k C:\Users\ConsultAir\Desktop\2279 saminole.rup Calc=MJ8 Front Door faces: W Job: Project Summary Date: 04/23/13 David C Brown Third By: ConsultAir, LLC Jacksonville,Fl 32207 Phonei(904)402-1463 Fax:(904)800-1222 Web WWW Loa dCalculat ions.corn Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FL 32233 Notes: Design Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 92 'F Inside db 70 'F Inside db 75 'F Design TD 31 'F Design TD 17 'F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 8788 Btuh Structure 10155 Btuh Ducts 1691 Btuh Ducts 2504 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10479 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 12292 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-loose Fireplaces 1 (Semi-loose) Structure 2452 Btuh Ducts 510 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 985 985 Equipment latent load 2962 Btuh Volume(ft) 8865 8865 Air changes/hour 0.64 0.30 Equipment total load 15254 Btuh Equiv. AVF (cfm) 95 44 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg. Make Goodman Mfg. Trade GOODMAN, JANITROL, AMANA DISTI... Trade GOODMAN, JANITROL, AMANA DISTI... Model GSZ130181A* Cond GSZ130181A* AHRI ref 3896069 Coil AR*Fl82416C* AHRI ref 3896069 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 12180 Btuh Heating output 17000 Btuh @ 47'F Latent cooling 5220 Btuh Temperature rise 27 'F Total cooling 17400 Btuh Actual air flow 580 cfm Actual air flow 580 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-24 13.14 57 -rrr wrightSOft- Right-Suitee U niv ersal 2012 12.1.07 RSL11 5431 Page 2 14CC'�, C.\Users\ConsultAir\Desktopk2279 Seminole.rup Calc=MJ8 Front Door faces: W Job: AED Assessment Date: 04/23/13 1st and 2nd By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(T) 70 75 Elevation: 13 ft Design TD (T) 31 17 Latitude: 30*N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 27.2 55.4 Dry bulb(*F) 39 92 Infiltration: Dailyrange(T) - 15 L V\L-tbulb(T) - 78 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Houdy Gazing Load ............................................... .......................-............................................... ................................................................. 4000--- 1111�� - 7,COD-- 6i000- Aoco-- AW-- 3,0013-- ZOOD-- 1,000-- 0 1 i i i i + 8 9 10 11 12 13 14 15 16 17 18 19 2D Hmr d Dw .1 H.udy A—g. Maximum hourly glazing load exceeds average by 20.9%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Apr-24 13:14 57 wrI9htS0ft* Right-SuiteC U niv ersal 2012 12.1.07 RSW 5431 Page I C:\Users\ConsultAir\Desktop\2279 Seminole.rup Calc=MJ8 Front Door faces: W Job: AED Assessment Date: 04/23/13 Third By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FIL 32233 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(*F) 70 75 Elevation: 13 ft Design TID(*F) 31 17 Latitude: 30'N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 27.2 55.4 Dry bulb(*F) 39 92 Infiltration: Daily range(*F) - 15 ( L V\Ietbulb(*F) - 78 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hoully Gazing Load 5CM...................................................................................... .................................................---—------------------------- 4,5M-- 4,OM-- In-Z 3�13M-- zn-- zom-- 1,50D-- 1'0M__ n__ 0 1 i + 4 i 8 9 10 11 12 13 14 15 16 17 18 19 20 Fbr d I* H-Hy A—W Maximum hourly glazing load exceeds average by 13.2%. Zone has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Apr-24 13:14 57 wrightSOft' Right-Su iteO u niv ersal 2012 12.1.07 RSU 15431 Page 2 C:kUsers\ConsultAir\Desktop\2279 Serninole.rup Calc=MJ8 Front Door faces: W Load Short Form Job: Date: 04/23/13 Entire House By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FIL 32233 Design Information Htg Cig Infiltration Outside db('F) 39 92 Method Simplified Inside db(*F) 70 75 Construction quality Semi-loose Design TD('F) 31 17 Fireplaces 1 (Semi-loose) Daily range - L Inside humidity 50 50 Moisture difference(gr/lb) 27 55 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btu h Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Cig load Htg AVF CIg AVF W) (Btuh) (Btuh) (cfm) (Cfm) Third d 985 10479 12659 580 580 1 st and 2nd d 1322 18169 16274 780 780 Entire House d 2307 28648 28934 1360 1360 Other equip loads 0 0 Equip. @ 0.97 RSM 28094 Latent cooling 6137 TOTALS 2307 28648 34231 1360 1360 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-24 13:15 50 wrightsoft Right-Su ite(E)u niversal 2012 12.1.07 RSU 15431 Page 1 C:\Users\ConsultAir\Desktop\2279 Serninole.rup Calc=MJ8 Front Door faces: W Load Multizone Summary Report Job: Date: 04123113 By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web www.LoadCalculations.com Infiltration Summary Heating Cooling ZONE NAME Volume ACH AVF HTM Volume ACH AVF HTM f? cfm Btu htf? ft3 CfTn Btu htft2 Third 8865 0.64 95 6.0 8865 0.30 44 1.5 1st and 2nd 12777 0.61 131 6.0 12777 0.29 61 1.5 Entire House 21642 0.62 225 6 0 T 21642 0.29 105 1.5 Load and AVF Summary ROOM NAME Area Htg load Cig load Htg AVF Clg AVF ft2 13tuh Btuh cffn cfm 3rd Floor 985 10479 12659 580 580 Third 985 10479 12659 580 580 2nd Floor 879 9752 10449 419 501 lst Floor 443 8418 5825 361 279 lst and 2nd 1 1322 1 18169 1 16274 1 780 780 Entire House 2307 28648 28934 1360 1360 2013-Apr-24 13:15 50 wrightSOft' Right-Suite4D U niversal 2012 12.1.07 RSUI 5431 Page I C:%Users\ConsultAir\Desktop\2279 Seminole.rup Calc=MJ8 Front Door faces: W Job: Building Analysis Date: 04123M3 Entire House By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web:www.LoadCalculations.com Project Information For NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FL 32233 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Ind oor tern p erature (T) 70 75 Elevation: 13 ft Design TD (T) 31 17 Latitude: 30*N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 27.2 55.4 Dry bulb(*F) 39 92 Infiltration: Da i ly range(T) - 15 ( L Method Simplified V\/etbulb(*F) - 78 Construction quality Semi-loose Wind speed(mph) 15.0 7.5 Fireplaces 1 (Semi-loose) INEENT,"Mms I -Component Btu h/ft2 Btuh %of load Walls 5.4 7142 24.9 Glazing 18.4 5904 20.6 Doors 12.2 451 1.6 Ceilings 1.5 1503 5.2 Floors 2.2 2138 7.5 Infiltration 6.0 7781 27.2 Ducts 3728 13.0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 28648, 100.0 Component Btu h/fl? Btu h %of load Walls 3.4 4572 15.8 Glazing 35.1 11251 38.9 Doors 12.1 447 1.5 Ceilings 2.7 2614 9.0 Floors 0.5 538 1.9 Infiltration 1.5 1967 6.8 Ducts 4395 15.2 Ventilation 0 0 Internal gains 3150 10.9 Blower 0 0 Adjustments o Total 1 28934, 100.0 Latent Cooling Load 6137 Btuh Overall U-value=0.149 Btuh/fe-*F Data entries checked. 2013-Apr-24 13:15:50 WriightSOft' Right-SuiteO u niversal 2012 12.1.07 RSUI 5431 Page I A--dk C:\Users\ConsuitAir\Desktop\2279 Serninole.rup Calc=MJ8 Front Door faces: W Component Constructions Job: Date: 04/23113 Entire House By: David C Brown ConsultAir, LLC Jacksonville,Fl 32207 Phonei(904)402-1463 Fax:(904)800-1222 Web:VAVW.LoadCalculations.com Project Information For: NorthPort Heating and Air 2279 Seminole Road#10, Jacksonville Beach, FIL 32233 Design Conditions Location: Indoor: Heating Cooling Mayport Ns, FL, US Indoor temperature(OF) 70 75 Elevation: 13 ft Design TD(OF) 31 17 Latitude: 30*N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 27.2 55.4 Dry bulb(OF) 39 92 Infiltration: Dailyrange(OF) - 15 L Method Simplified Wet bu I b(OF) - 78 Construction quality Semi-loose Wind speed (mph) 15.0 7.5 Fireplaces I (Semi-loose) Construction descriptions Or Area U-value Insul R Htg HTM Loss C19 HTM Gain re Bhh/ff-'F ft2-*F/BbA1 BtLh/ft2 Btuh l3bhIff Btuh Walls 13A-4oGs:Blk wall,stucco ext,r-4 ext bd ins,6"thk, 1/2"gypsum n 83 0.143 4.0 4.49 373 2.85 236 board int fhsh e 364 0.143 4.0 4.49 1636 2.85 1037 s 123 0.143 4.0 4.49 552 2.85 350 w 384 0.143 4.0 4.49 1723 2.85 1092 all 954 0.143 4.0 4.49 4284 2.85 2715 Partitions 12A-Osw:Firm wall, 1/2"gypsum board int fnsh,Tx4"wood frm 379 0.240 0 7.54 2858 4.90 1857 Windows I 013-v:2 glazing,clr outr,air gas,vni frm mat,clr innr,1/4"gap,1/8"thk; e 15 0.600 0 18.8 283 12.1 182 40%blinds 45',lig ht;50%outdoor insect s creen;7 f t overhang(5 f t window ht,1.5 ft sep.) 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,cir irl 1/4"gap,1/8" e 13 0.570 0 17.9 239 57.1 762 thk;50%outdoor insect screen;1.5 ft overhang(2.67 ft window ht,1.5 ft sep.) 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,clr innr,1/4"gap,1/8" e 54 0.570 0 17.9 959 32.7 1755 thk;50%outdoor insect screen;7 ft overhang(6.7 ft window ht,1.5 ft e 121 0.570 0 17.9 2158 32.7 3949 sep.) all 174 0.570 0 17.9 3118 32.7 5704 1 D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,cir innr,1/4"gap,1/8" e 35 0.570 0 17.9 634 26.2 929 thk;40% blinds 45*,light;50%outdoor insect screen;7 ft overhang (6.25 ft window ht,1.5 ft sep.) 1 D-c2ovd:2 glazing,dr outr,air gas,vni frm mat,dr innr, 1/4"gap,1/8" e 42 0.570 0 17.9 746 27.6 1150 thk;40% blin ds 45*,lig ht;50%outdoo r inse ct sc reen;7 ft over hang w 17 0.570 0 17.9 298 27.6 460 (6.67 It window ht, 1.5 ft sep.) all 58 0.570 0 17.9 1044 27.6 1610 1 D-c2ov:2 glazing,clr outr,air gas,vni frm mat,clr innr,1/4"gap,1/8" w 4 0.570 0 17.9 72 48.1 192 thk;40% blin ds 45 0,lig ht;50%outdoo r inse ct sc reen 1 D-c2ov:2 glazing,clr outr,air gas,vni frm mat,clr innr,1/4"gap,1/8" w 13 0.570 0 17.9 224 35.5 444 thk;40% blinds 45*,light;50%outdoor insect screen;3 ft overhang (2.5 ft window ht,1.5 ft sep.) 8Acw-2w:Sky glazing,small,wood curb,no shaft lgt shaft,wd sash; 8 1.160 0 36.4 291 178 1427 50%outdoor insect screen;1.5 ft overhang(1 ft window ht,10 ft sep.) 2013-Apr-24 13:15:50 qw- wrightsoft' Right-SuitaO U niversal 2012 12.1�07 RSUI 5431 Page I ACCI`- C:\Users\ConsultAir\Desktop\2279 Serninole.rup Calc=MJ8 Front Doorfaces: W Doors 11 DO:Door,wd sc type w 20 0.390 0 12.2 246 12.1 244 n 17 0,390 0 12.2 205 12.1 203 all 37 0.390 0 12.2 451 12.1 447 Ceilings 1613-1 9ad:Attic ceiling,asphalt shingles roof mat,M 9 ceil ins,5/8" 977 0.049 19.0 1.54 1503 2.68 2614 gypsum board int fnsh Floors 20P-1 3t:Fir floor,frm flr,10"thkns,tile fir fnsh,r-I 3 cav ins,amb ovr 106 0.068 13.0 2.14 226 0.99 105 20P-1 3t:Fir floor,frm fir, 10"thkns,tile fir fnsh,r-1 3 cav ins,gar ovr 436 0.068 13.0 2.14 931 0.99 433 22A-tph:Bg floor,heavy damp soil,on grade depth,tile fir fnsh 23 1.358 0 42.6 981 0 0 2013-Apr-24 13:15 50 w1rightsoft' Right-Su ite(@ U niv ersal 2012 12.1.07 RSU 15431 Page 2 .Am C:\Users\ConsultAir\Desktop\2279 Seminole.rup Calc=MJ8 Front Door faces: W Right-JO Worksheet Job: Date: 04123/13 Entire House By: David C Brown ConsuMir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web www Loa dCa Iculat ions com 1 Room n me Entire House Third 2 Exposed wall 13TO ft 600 ft 3 Room height 9.4 ft d 90 ft d 4 Room dimensions 5 Room area 2307.0 ft2 985.0 ft2 I I I I Ty Construction If a. Or HTIM Area tt2j Load Area (ft2) Load I or i m(fe a r meter tuh) number F (Bt uh per (ft) (Btuh) or peri (ft) (13 Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.49 2.85 83 83 373 236 63 63 283 179 1 3A-4ocs 0,43 e 4,49 285 644 364 1636 1037 207 127 569 360 1013-v 0600 e 1884 12.13 15 13 283 182 0 0 0 0 1 D-c2o O�570 e 1 T90 57.11 13 0 239 762 13 0 239 762 11 ---G 1 D-c2ov 0570 e 1790 3274 54 34 959 1755 27 17 480 878 0.570 e 7.90 2624 35 24 634 929 0 0 0 0 1 D-c2ov 1 1316 ---G 1 D-c2ovd 0570 e 17.90 3274 121 78 2158 3949 40 26 719 ---G 1 D-c2ovd &570 e 1T90 2T60 42 27 746 1150 0 0 0 0 W 13A-4ors 0.143 s 4.49 2.85 123 123 552 350 63 63 283 179 3A-4oc 0.143 w 4A9 Z85 437 384 1723 1092 207 207 929 589 1 0 0 1 D-c2ov 0570 w 17 90 4808 4 0 72 192 0 0 1 D-c2ov 0570 w 17.90 3554 13 5 224 444 0 0 0 0 ID-c2ov 0,570 w 17.90 27.60 17 11 298 460 0 0 0 0 1DO 0390 w 12,25 12 13 20 20 246 244 0 0 0 0 1 0.240 - 7.54 4.90 396 379 2858 1857 0 0 R 12A-Osw 0 0 0 0 11 DO 0.390 n 12.25 12.13 17 17 205 203 0 0 16B-19ad 0,049 1.54 268 985 977 1503 2614 985 977 1503 2614 8Acw-2w 1.160 36,42 178A2 8 0 291 1427 8 0 291 1427 F 20P-1 3t 0.068 2.14 0.99 106 106 226 105 106 106 226 105 F 20P-13t 0,068 214 0,99 436 436 931 433 0 0 0 0 F 22A-tph 1.358 42.64 0.00 443 23 981 0 0 0 0 0 6 c)AED excursion 01 1 55231 0 Envelope loss/gain 1713j 194221 8410 12 a) Infiltration 7781 1967 3265 825 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 5 1150 4 920 Appliances/other 2000 0 Subtotal(lines 6 to 13) 24920 24538 -T 8788 10155 Less external load 0 0 0 0 0 0 Less transfer 0 0 Redistribution 0 0 24920 24538 8788 10155 14 Subtotal 15% 18% 3728 4395 19% 25-1. 1691 2504 15 Duct loads — 286481 289341 104791 126,591 Total room load 13601 13601 5801 580] Air required(cfm) I I I I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-24 13:15 50 4+f-- wrightsoft Right-Suite(D Universal 2012 121,07 RSU15431 Page 1 C\Users\ConsultAir\Desktop\2279 Seminole rup Calc=MJ8 Front Door faces: W Right-JO Worksheet Job: Date: 04123/13 Entire House By: David C Brown ConsuftAir, LLC Jacksonville,Fl 32207 Phone:(904)402-1463 Fax:(904)800-1222 Web.www LoadCa Iculat ions com 1 Room name 1 st and 2nd 2 Exposed wall 770 ft 3 Room height 97 ft d 4 Room dimensi ns 5 Room area 1322.0 ft2 I I I I I I Ty � Construction U-value Or I HTIV!t�) Area (ft2) Load Area Load number Btuh/W-'F� (Btuh/ or perimeter (ft) (Btuh) or perimeter I I Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-4ocs 0.143 n 4.49 2.85 20 20 90 57 13A-4ocs 0143 e 449 2,85 437 238 1067 676 ---G 1 OEI-v 0.600 a 18,84 12.13 15 13 283 182 1 D-c2ov 0,570 e 1 7.90 57,11 0 0 0 0 11 ---G 1 D-c2ov 0570 e 1790 3274 27 17 480 878 1 D-c2ov O�570 a 1 7,90 2624 35 24 634 929 --G D-c2ovd 0.570 e 1790 3274 80 52 1439 2633 ---G 1 D-c2ovd &570 e 17.90 2760 42 27 746 1150 W 13A-4ocs 0.143 s 4.49 2.85 60 60 269 171 1 3A-4o s 0.143 w 4.49 285 230 177 794 503 1 D-c2ov 0.570 w 1 7,90 4808 4 0 72 192 1 D-c2ov 0,570 w 17 90 3554 13 5 224 444 1D-c2ov 0570 w 17 90 2760 17 11 298 460 11DO 0,390 w 1Z25 1213 20 20 246 244 R 12A-Osw O�240 - 7.54 4.90 396 379 2858 1857 L—D 11 DO 0.390 n 12.25 12.13 17 17 205 203 16B-19ad 0,049 1,54 268 0 0 a 0 8Acw-2w 1 160 36,42 178,42 0 0 0 0 F 20P-13t 0.068 2.14 0.99 0 0 0 0 F 20P-1 3t 0.068 2.14 099 436 436 931 433 F 22A-tph 1.358 42.64 0.00 443 23 981 0 1 0 j1 61 c)AED excursion Envelope loss/gain 116161 110121 1 1 1 12 a) Infiltration 4516 1141 1 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 1 230 Appliances/other 2000 Subtotal(lines 6 to 13) 16132 14383. Tless e emal load 0 0 L.::tr xt 1 0 0 xt Less I s an�f.r .,is r ).,i.r 0 0 Redistribution Su'to In'1 16132 14383 141 S ubtota' 1891 1, Duct 1. 's 13% 2037 15 Duct loads 13% Total room load 181691 162741 1 1 1 Air required(cfm) 780 780 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Apr-24 13:15 50 4++- wriightsc)ft Right-Suite(D Universal 2012 121,07 RSU15431 Page 2 C\Users\ConsultAir\Desktop\2279 Seminole.rup Calc=MJS Front Door faces W CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 -5814 INSPECTION PHONE LINE 247 Application Number . . . . . 13-00003533 Date 10/16/13 Property Address . . . . . . 2279 SEMINOLE RD UNIT 010 Application type description ELECTRIC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ----------------------- -- -------------------------------------------------- Application desc breaker change for ac ------------------------------- -- ----------------------------------------- Owner Contractor-------------- ---------- ----- ------------------ LIN' S ELECTRIC INC DRISCOLL, KEVIN 3840 MAGILL RD 2279 SEMINOLE RD # 10 FL 32220 ATLANTIC BEACH FL 32233 JACKSONVILLE (904) 545-1346 ---------- ----------------------------------------------------------------- Permit . . . . . . ELECTRICAL PERMIT Additional desc . - 60 . 00 Plan Check Fee . 00 Permit Fee . . . . Valuation . . . . 0 Issue Date . . . . Expiration Date - - 4/14/14 -------------------------------- - -------- ---------------------------------EC DCA SURCHARGE 2 . 00 Other Fees . . . . . . . . . STATE EL STATE ELEC DBPR SURCHARGE 2 . 00 -------- --- ------- ---- ------------------------Charged Paid Credited Due Fee summary ---------- ---------- ------ --- ----- Permit-Fee-Total --- 60 . 00 60 . 00 . 00 . 00 Plan Check Total . 00 ' 00 . 00 . 00 other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 64 . 00 64 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd, Atlantic Beach, Fl, 32233 Ph(904) 247-5826 Fax (904) 247-5845 PERMIT p JOB ADD Ess: ,2Z79 AMPS 24c VOLTS 02i& PHASE JEA INFORMATION REQUIRED ON ALL PERMITS 2-so VALUE OF WORK NEW SERVICE 0 Overhead F-1 Underground Underground up Pole OResidential(Main) Service [10-100 amps [1101-1 50amps 0 151-200amps O-amps of Meters 0 Commercial(Main) Service 0 151-200amps amps OCT Service-amps 00-100 amps �]101-150amps Conductor Type, Size OMulti-Family(Main) Service #of Unit Meters 00-100 amps 0 10 1-15 Oamps 0 151-200amps O-amps OTemporary Pole O-amps SERVICE UPGRADE O-amps [I CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) OCT Service amps 0100amps [1150amps 0200amps F1 .....amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 0-30amps -31-100amps -101-200amps Appliances: 0-30amps _31-100amps -101-200amps A/C Circuits: 0-60amps _61-100amps Heat Circuits: # circuits Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS KVA 0 Motors hp 0 Swimming Pool 0 Sign [I Smoke Detectors_Qty El Transformers- FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK Qty_volts/amps REPAIRS/MISCELLANEOUS ion OPanel Change OOH to UG 0 Replace Burnt/Damaged Meter Can I I Safety Inspect OOther: Bvx-, Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number Electrical Company L 'S -OfficePhone Co.Address:�350 PAftAt 141 City�_aAL"" . L State F1 Zip A2-10 V Le 1?4� Jo-, State Certification/Registration#6*30'5 4 97' License Holder(Print): Notarized Signature of License Hold& Before me this of 20 Signitature of Notary P