Loading...
1505 Jordan St HVAC 2013 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �J13ISA Application Number . . . . . 13-00002835 Date 6/20/13 Property Address . . . . . . 1505 JORDAN ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc CHANGE OUT 2TONS 12K BTU' S ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BRANCH, SHEILA FLORIDA HOME AIR GOND DBA ARS 1505 JORDAN STREET 4211 EMERSON ST ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32207 (904) 777-4300 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/17/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904) 247-5845 dOB ADDRESS: ��0 ` �G'YG�Qj� ,Sy E-c 7 PERNIIT# PROJECT VALUE$ I `, NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATIDN ARI# Sq of 7(ArJ3 Air Conditioning: Unit Quantity 'Pons Per Unit 2- REQUIRED Heat: Unit Quantity BTU's Per Unit /yoc>C> Seer Rating /U)U Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER 6-X 5 i;ncI Cit.nU O (-)T. Permit becomes void if work does not commence within a six month period or work is suspended or ahandoned for six months.I hereby certify that I have read this application and know the same to be tntc and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit docs not give authority to violate the provisions of any other state or local law regulation consintction or the perfotnianee of constntetion. Property Owners Name SK C'I /Q f(j } Phone Number Mechanical Company Ars rjl)rl 12/4- //klm E Office Phone 717 T3M Fax -� Co. Address: "7 Z l j jCM"0,i-.SONI City� State fL Zip.32 License Holder (Print): e 5 (.C) St Certification/Registration l,'(me-k*z 1(-c 31� Notarized Sigitalitre of License Holder- � EEDV0111 and subscribed bcfo me t � a 20 45 , Stade of Florida S mature of Notary Publ'con EE 85079012017 i This combination qualifies for a Federal Energy ■ , Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 5429653 Date: 6/10/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: RPRL-025JEC Indoor Unit Model Number: RHPL-HM2421+RCSL-H"2621 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM RPRL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 25400 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 17.00 Heating Capacity(Btuh) @ 47 F: 22600 Region IV HSPF Rating (Heating): 9.00 Heating Capacity(Btuh) @ 17 F: 14000 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data.unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information forthe model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. on -' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130153437813228724 1 Des ig n5tar Load Calculation Results are intended for use with Rheem heating and cooling systems the New Degree of CorWor" • Information Street Address 1505 JORDON STREET, Atlantic Beach, FL 32233 _........................_....................__. _.............._....................................._..................................._.................._........_....._.._..._.............................._._.............. _ Latitude, Longitude 30.33750, -81.76860 House Square Footage: 1140 sq. ft. Name: SHEILA BRANCH Phone: 904-241-5852 Email: ..............................................................................................._................._....-............................................................................................................_...___................._......................._........................................__....... liHouse Information SHR .75 Number of residents 2 ...................._.........................................................................................................._...................._....................................................._..._............_.......................__........._...............--........................................... Ceiling height 9 Wall U-value R-value 0.09 1 11 _........................... _............1-1.11- . . __._1......................................................................................._.._............................._._..........._........_.............._.._....................................................................... .......... Floor U-value R-value 0.2 15 Ceiling U-value I R-value 0.053 ( 19 .......................... .............................................................................................._................... .._.............._.....................___ __ __ ...................................... Window U-value 0.5 Window SHGF 0.85 ..............................................................................................................................................................................................................................................._...................................................................................................... Moisture grains 53 Duct loss % 10 ..................................._................_............_................................._............................._............_................__...-.._.................._......_......._................................................... Duct gain % 10 _..............................................................................._....................................._.............................._........................................._......_.........................._..._..................._......................._............ ........._......_.................. Cooling infiltraction (ACH) 0.6 __................_.........................................._........................................_....................................._........................_....._...... ................... .......... Heating infiltration (ACH) 0.8 Winter ventilation 0 ...................................._......................_......................._......_.......... ..... ............... Summer ventilation 0 ',Design Conditions Outdoor Heating Cooling Dry bulb (°F) 32 93 Daily range M ..................._...-..._............_........._.....___-- _ _ ..................... . ............. _. Relative humidity 50% .................................................._.............._............._........_.._.._..._......_........................._..._......._................_.._............................._................_........................._..........._.......................................................... 11 Moisture difference 53 Indoor Heating Cooling Indoor temperature (°F) 710 75 Design temperature difference(OF) 38 18 _............................_....................................................................................................................................._......................................................................._...................................................._................._..._..._.._......._.._..... ;HeatingLoads Area Btuh % of load Wall 3593 17.1 ...................._...................................._................_......................._..........._....................__....................................._.. Floor 4788 22.8 Ceiling 2296 10.9 Windows 3135 14.9 ---_.............. ............................_....................._............_............_._........_................ Infiltration 5318 25.3 ........................................................._...._.......__.............................._................................. .........._ System Efficiency Loss 1913 9.1 Tota I: 21043 .........._...................--............._.__._.__................_................................_._........................................ Heating Loads 21,043 BTU/hr r System Efficiency Loss Infiltration IPA/ Ceiling Iz— �-Windows i Floor J Wall oolinq Loads Area Btuh % of load ......_......._................_......_..............................................................._.. Wall 2647 10.5 Ceiling 3202 12.7 Windows 9159 36.3 .........................__................._.............._............................_..._..__.__..................._...... Sensible Infiltration 1889 7.5 _.............................._....................................._.._.......... ................._....................._....._......................... ..... Latent Infiltration 3439 13.6 System Efficiency Gain 2034 8.1 Internal 1938 7.7 ............. ..... ...................... .... Sensible People Load 460 1.8 Latent People Load 460 1.8 Total: 25228 _.........._........_.................................._.................................._......_........._..............._........................_............... . Sensible load 21329 .................................................._......... ._......................_ Latent load 3899 ............................................................._..........._.............._.......,................._..__.._.._..._..........._.................................._..... SHR 0.85 Capacity at .75 SHR 2.37 Tons Cooling Loads 25,228 BTU/hr i Sensible People Load ! Latent People Load �-Sensible Infiltration Internal Windows -� �—System Efficiency Wall Latent Infiltration J `Ceiling AED Graph 10000 � I 0 J 5000 0 Sam 9am 10am Ilam 12pm 1pm 2pm 3pm 4pm Spm bpm 7pm Bpm Hourly Loads —Average • • selection System equipment selection will be made using the following derived values. Glass (E) 83 sq. ft. _ ............ ......................._..... ......... Glass (S) 12 sq. ft. ................. ................... ....._......._... .............. Glass (N) 12 sq. ft. _........_...__._. ... .. ......................................................................._....._........... Glass (W) 58 sq. ft. ............... Summer Outdoor 93°F Summer Wet Bulb 77°F ..........................._........................._............................................................._..._.._....................._...._........................... Summer Indoor 75°F ....._...__....... . Summer Design Grains 50% ....................__............................................................................................... Winter Outdoor 32°F . Winter Indoor 70°F ...................__..................._.._......................................_......................................... Sensible Cooling 21,329 Btuh ................_................................._......__....._..........._......._..._......_._.. Latent Cooling 3,899 Btuh _ _...__..__.._........_.........................___......_...._............................. Required Cooling Airflow 970 CFM _...-.................................._.._.........._..................._.._......._.._._.__.._..._._.__... Sensible Heating 21,043 Btuh ..................................................................................................................._.................................._..........--........................._........... Required Heating Airflow 273 CFM ....................__.._............................._.............._.............................._................................................................................................. All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree