360 5th St SFR 2013 •..++'LTJ f+lv, .
CITY OF ATLANTIC BEAT H.
r) 800 SEMINOLE ROAD
J , ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002832 Date 6/20/13
Property Address . . . . . . 360 5TH ST
Application type description SINGLE FAMILY RESIDENCE
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 400000
----------------------------------------------------------------------------
Application desc
NEW HOME
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
AF AB VENTURE LLC ELITE HOMES INC.
357 12TH ST 357 12TH ST
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 349-2803
--- Structure Information 000 000 NEW HOME
Construction Type . . . . . TYPE 5-B
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . SINGLE FAMILY DWELLING NEW
Additional desc . .
Permit Fee . . . . 955 . 00 Plan Check Fee 477 . 50
Issue Date . . . . Valuation . . . . 400000
Expiration Date . . 12/17/13
----------------------------------------------------------------------------
Special Notes and Comments
Avoid damage to underground water/sewer utilities . Verify
vertical and horizontal location of utilities . Hand dig if
necessary. If field coordination is needed, call 247-5834 .
Ensure all meter boxes, sewer cleanouts and valve covers
are set to grade and visible .
A sewer cleanout must be installed at the property line.
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
A reduced pressure zone backflow preventer must be
installed if irrigation will be provided or if there is a
private well on the property. Backflow preventer must be
tested by a certified tester and a copy of the results sent
to Public Utilities .
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
All concrete driveway aprons must be 5" thick, 4000 psi,
with fibermesh from the edge of pavement to the property
line . Reinforcing rods or mesh area not allowed in the
PERMITISIAigh)tVE®fi?ikJagq.ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
j CITY OF ATLANTIC BEACH
s) 800 SEMINOLE ROAD
_4t 800
BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
�Jj31>�
Page 2
Application Number . . . . . 13-00002832 Date 6/20/13
------------------------------------------------------------------------
Special Notes and Comments
Full right-of-way restoration, including sod, is required.
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O.
A sewer cleanout must be installed at the property line .
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
*SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST
CONTROL COMPANY PRIOR TO C.O.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE DCA SURCHARGE 14 . 33
DEV REVIEW-SINGLE & 2-FAM 50 . 00
ENG REV RESIDENTIAL BLD 100 . 00
STATE DBPR SURCHARGE 14 . 33
SEWER SDC-SYSTEM DEV CHG 4050 . 00
UTIL REV PRE APP >3 HRS 50 . 00
WATER CONNECT/METER ONLY 185 . 00
WATER CROSS CONNECTION 50 . 00
WATER SDC-SYSTEM DEV CHG 1140 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 955 . 00 955 . 00 . 00 . 00
Plan Check Total 477 . 50 477 . 50 . 00 . 00
Other Fee Total 5653 . 66 5653 . 66 . 00 . 00
Grand Total 7086 . 16 7086 . 16 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
A"
BUILDING PERMIT'APPLICATION 0 �(
EILEop CITY OF ATLANTIC BEACH JUN OA
2013
800 Seminole Road, Atlantic Beach, FL 32233
Office (904)247-5826 Fax(904)247-5845
Job Address: 5 ^ 5fuz dnl�-C �GR I �L Permit Number: a
Legal Description Orr 9-7 610614 60 OA-f-Ab-1 iri5ivry Parcel# 10914S- 0970
Floor Area of q. t. �q.F't
Valuation of Work$_ 4.001 DOD Proposed Work heated/cooled,35a6 non-heated/cooledIva a
Class of Work(circle one): (S) Addition Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s)(circle one): Commercial Residentia
If an existing structure,is a fire sprinkler system installed? (Circle one): es No
Florida Product Approval#
For multiple products use product approval foildi
Describe in detail the type of work to be performed:—,&/6,.C) -�I f e
Property Owner Information:
Name: 1'-' Address:
City__ State�LZip 3ol;(33 Phone o'%- 7/6 37g7
E-Mail or Fax#(Optional)
Contractor Information: l
Company Name: �� �M:°.5 L Qualifyin Agent: efhle 5 G�4 �i er?3�ti
Address: _ e / —jr City ,44,Vb i l� a, State Zip �3
Office Phone_gD ZSlD3 Job Site/Contact Number /-36/9-Zf3'c53 Fax#
State Certification/Registration# C6(- C7 190
Architect Name&Phone#
Engineer's Name&Phone# /5 it die2l - o
Fee Simple Title Holder Name and Addfess
Bonding Company Name and Address 4-14 f
Mortgage Lender Name and Address
Application is hereby made to obtain a permit to do the work and installations as indicated I cert that no work or installation has commenced prior to the
issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes ritrll
and void if work is not commenced within six(ti)months, or if construction or work is sus ended or abandoned for aperiod of six(6)months at any time anter
work is commenced. 1 understand that separate permits must be secured for ETectricalpWork,Plumbing,Signs, Wells, Pools, Furnaces, Boilers,Neaiers,
Tanks and Air Conditioners,etc
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTENT) TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
1 hereby certifv that I have read and examined this plication and know the same to be true and correct. All provisions of laws and ordinances governing this
type p(work will be complied with whether spec!ted herein or not. The granting of a permit does not presume to give authority to violate or cancel the
provisions of any other federal.state, or local law regulating construction or the performance of construction.
Signature of Owner � AIA4 AA'
Signature of CoclPrint Name ............ Print N �1.. ✓"----------------------------.....
----------- -------------- . ...
Swor and subscrib ble me Sworn to nd subscribed before me
thi D f 20 this L6Day�of A 20 /3
otary I i. �* My COMMISSION#OD 9 ota
* 14,2014
EXPIRES,February ,: 'ry JENNIFER WALKER
', R y�ded Thm Notary Public Undervrtit�rs _*. ;. MY COMMISSION#FF 011 ftv 1 d 01.26.10
W a'•. a: EXPIRES:April 24,2017
Bonded Thru NotaryPublic Underwriters
NOTICE OF C01 ENCEjV-FZPr P` FILE Cif
S'
(PREPARE IN DUPLICATE) _
Permit No. — 9 O _ _ iax Folio No.State of ! �� — �v County of %Q�
To whom it Thlay con"rll:
The undarsigned hereby informs you Viet Improvements w€it be trade to ceif,3in real property,and jr,
accordance with Section 713 of ttie Ftorlda Statutes,tare foi(ovring information is stated in this fdGTICE OF
COMIMENCEMENT.
t��
Level description of property being unproved: �i �� b[oc.�f � t NIL
`l L2 i9)211r`t'7
Address of props-ty bein7 improved:
General description of it provements: A,1&0='�LLiill C� �lyvi i+� �?��
Address V.h-ymrui,v. . -t
, rte--`�
1. �. •"``�-t✓�v�ic, rpt, i=L 3��3.�
Owner's interest in site of the improvement_ tee
Fee Simple itieholder(if ether than owner)
lvame
Address
Address r.� t{S,Z{ l �yf 'ta'. '� '�i'�„�nlfi-' .,4r 5/*3j
i ft LTJ Phone No. �(V�". �-1 f '�t�✓� _F8X N0.
II',
Surety elf any)�1✓�
Address _ Amount of hand
Phone no. Fax No.
Name and address of Eny person maKing-a loan or the cons'.action of the i;rpravaments.
Blame NIS'
Address
Phone No.
rax No.
Name of person within,the State of Florida,other than himself,designated by owner upon whom notices or other
documents may bgserved:
Marne_ All'q`
Address
Phone No. Fax No.
In addition to himself,ohner designates the 10HOwing person t0 rerPive a copy 0f the Lienor's Notice as provides!in
Section 713.06(2)(b),Florida Siatutes.(HI in at 04vners option).
Name_ my./W
Address
Phone No. Fax No.
Expiration date of Notice of Commencement(the expiration date is one(1)year tram the date of recorrifng mess a
different dale Is specified):
7-HIS SPACE FOR RECORDER'S USI-'QIvE°Y � OIfJI�ER �
,�
gned: u'✓'61 �n1 0( Q jwi lam.
siofS AE
Before me,hls day of in the
-------
County of Duval,Stag of Florida, res persana ry appeared
--------------
Dec 20 i 31 d f886,OP.8K 16?01 Page 1131, i herel.�by
himself;herself and affirms that all s,a(eraents and declarations herein
Number Pages:1 f are rose and ate
Recorded 06,107 X013 at 10:03 AM, l
Ronnie Fussell CLERK CIRCUIT COURT DUVAL
COUNTY
RECORDING$10.00 — � L
I f:ca bis lLur csfr :.. ^c. f t
Pr apt0
Cal UP.
IH S:,Pt f,aq 14 L TzE / �/
DO NOT WRITE BELOW- OFFICE USE ONLY
Applicable Codes: 2001 Florida Building Code w Revisions
Review Result (circle one)•
Approved Disapproved Approved w/ Conditions
Review Initials/Date:
Development Size
Habitable Space Non-Habitable
Impervious area .Eo v
Miscellaneous Information
Occupancy Group R – .3
Type of Construction -
Number of Stories
Zoning District /�S
Max. Occupancy Load
Fire Sprinklers Required
Flood Zone — 4/4
Conditions/Comments:
tL1rJ CITY OF ATLANTIC BEACH
r S, Building Department
800 Seminole Road
J Atlantic Beach,Florida 32233
(904)247-5800
PLAN REVIEW COMMENTS
Permit Application # -2,5 .3 a
Property Address: 360 S �{ S le
Applicant: , /yos-n2 s'
Project:
This permit application has been:
Approved
Reviewed and the following items need attention:
/n 0k3 000
r -
Please s re-submit your application when these items have been completed.
Reviewed By: . /77 OL Date: Ghi—!�
Vis_% Vi- City of Atlantic Beach APPLICATION NUMBER
\mss Building Department (To be assigned by the Building Department.)
j I s 800 Seminole Road
Atlantic Beach, Florida 32233-5445 0
Phone(904)247-5826 • Fax(904)247-5845
j; E-mail: building-dept@coab.us Date routed: 1Y
City web-site: http://Www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: 3 �� 47— ment review required Ye No
Bu'
Applicant: Planning &Zoni
��// '- / ree inistrator
Project: //�h /7�D /1� L ublic Works
ublic Uti i i
u is a ety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: proved. ❑Denied.
(Circle one.) Comments:
UILDI
PLANNING &ZONING Reviewed by: Date:
TREE ADMIN. Second Review: ❑Approved as revised. F-]DeniecO
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
Revised 05/14/09
TREE & VEGETATION REMOVAL PERMIT APPLICATION
INSTRUCTIONS t City of Atlantic Beach
Department of Community Development
(1) Complete and sign this form. 800 Seminole Road Atlantic Beach,FL 32233
(2) Attach the required supporting exhibits as listed on the application (P)904247-5800 (F)904 247-5845
checklist.
(3) Contact the Department of Community Development if you have (— Single-/Two-Family Residential $125.00
questions or need assistance completing the application or
determining which exhibits are required for your particular project. r Multi-Family Residential $250.00
(4) Submit this form, along with all required exhibits and payment to r Commercial/Industrial $250.00
the City of Atlantic Beach,and in the appropriate amount according
to the application fees listed to the right, to the reception desk at r Institutional/Other Non-residential $250.00
the Building Department.
f
Application#TREE -
SECTION 1-SITE INFORMATION
PHYSICAL ADDRESS 3� GfA5f/,k- i I L �L 3223 3
If an address has not been assigned to this p/ropT efrty�clolntact the AB Building Department at(904)247-5826 to request an address.
SUBDIVISION "A ri BLOCK (p LOT (97 RE# / � + �^ X70
SECTION 11-APPLICANT INFORMATION rf WNER r LEGAL AUTHORIZED AGENT
NAME OF APPLICANT AiG V&vfilS
ADDRESS OF APPLICANT ✓� �iYflNu 2I(1ke �, FL 3z:2-33
���i L
PHONE CELL l 716.3787 EMAIL
SECTION III-TREE&VEGETATION REMOVAL REQUEST
I REQUEST THAT THE TREES&VEGETATION ON THE ABOVE DESCRIBED PROPERTY AND INDICATED ON THE ATTACHED REQUIRED
EXHIBITS BE APPROVED FOR REMOVAL,AS PROVIDED IN THE CITY OF ATLANTIC BEACH VEGETATION CODE,CHAPTER 23, FOR THE
FOLLOWING REASONS(check all that apply):
r
Vegetation(trees)are difficult to maintain/ownerdislikes.
Trees are dead,diseased or so weakened by age,storm,fire,or other it* ryso os to pose a dang r to pers s,pro rty,
improvements or other trees. �1�,00 �/Ir �12Laf
r Vegetation(trees) pose a safety hazard to pedestrian or vehicular traffi� a di ption to publ' utility services.
(— Vegetatiait(trees)pose a safety hazard to buildings or structures.
tZ
F— Vegetation(trees)completely prevent access or cross access to a lot or parcel.
Vegetation and/or trees prevent development or physical use. It is the intent of this provision that a permit shall be granted for
F the removal of vegetation and/or trees when the applicant has demonstrated an effort to design or locate the proposed
improvements so as to minimize the removal of vegetation and/or trees.
I HEREBY CERTIFY THAT ALL INFORMATION PROVIDED WITHIN THIS APPLICATION IS CORRECT AND I AGREE TO COMPLY
WITH ALL PROVISIONS OF CHAPTER 23,PROTECTION OF TREES AND NATURAL VEGETATION,AND ALL OTHER APPLICABLE
CODES A D ORDINANCES OF THE CITY OF ATLAN : C
1� ^ k
at
\X 1A � I A t
SIGNATURE O APPLICANT DATE s
FOR INTERNAL OFFICE USE ONLY
FRONTAGE FLU ZVAR ESA SR-1
DEPTH ZONING UBEX H/H SR-2
AREA ISA WAIV OAB CR
Tree&Vegetation Removal Permit Application_versionozot.oy i
rt}r'`F('
fs_L�� City of Atlantic Peach ,JUN (_Uig � APPLICATION NUMBER
Building Department j (To be assigned by the Building Department.)
r 800 Seminole Road BY: / S
Atlantic Beach, Florida 32233-5445 0 li
Phone(904)247-5826 - Fax(904)247-5845
LJ;�9Y E-mail: building-dept@coab.us L Date routed: (Y. e
City web-site: http://wwvv.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: (Q Jr DapaLtment review required Yes No
Bui
Applicant: ,fl Gs Planning &Zoni
re inistrator
Project: /�lV /4 ublic IN
�Ppublic Uti i i
Pu tc a ety
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: , Approved. []Denied.
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Date:
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied.
C WORK Comments:
BLIC UTILIIT3
P BLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
Revised 05/14/09
Ss� CITY OF ATLANTIC BEACH
j ? PUBLIC UTILITIES
1200 Sandpiper Lane
ATLANTIC BEACH, FL 32233
(904)270-2535 or(904)247-5874
NEW WATER/SEWER TAP REQUEST
Date: �l(0 2-�3 Project Address: 340 s%-4 ST-
No. of Units: Commercial Residential Multi-Family
New Water Tap(s) &Meter(s) Meter Size(s) 31q-`r
New Irrigation Meter Upgrade Existing Meter from to (size)
New Connection to City Sewer_��
Name:
Applicant Address:
City: Atlantic Beach State: Zip:
Phone Number: Cell Number:
Email Address Fax:
Signature:
(Applicant)
Application# /3 —z F3 2 CITY STAFF USE ONLY
Water System Development Charge $ 1. 140-06
Sewer System Development Charge $ -W
Water Meter Only $ ( 185--. 00
Water Meter Tap $ (notes)
Sewer Tap $
Cross Connection $
Other $
TOTAL
APPROVED:
(Utility Director or AjAorized Signature)
ALL TAP REQUEST MUST BE APPROVED BY UTLITIES DEPARTMENT BEFORE FEES
CAN BE ASSESSED
City of Atlantic Beach APPLICATION NUMBER
aJs ; Building Department (To be assigned by the Building Department.)
t 800 Seminole Road / p Z P
Atlantic Beach, Florida 32233-5445 e� 0
Phone (904)247-5826 • Fax(904)247-5845
E-mail: building-dept@coab.us Date routed: 1Y Ile 11.g
City web-site: http://www.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: �(� .� d-� ment review required Yes No
f — — / Bu.
Applicant: �/ �� /J�GS Planning &Zoni
// ree inistrator
Project: /r�j1� A ublic Works
Public Uti i i
u is a ety
Fire Services
Review fee _ 6�w Dept Signature
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. ❑Denied.
(Circle one.) Comments:
G
PLANNING &ZONING
Reviewed by; Dater 41211
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
i
Comments:
Reviewed by: Date:
Revised 05/14/09
RE r 'D
Ys!'bl f J, City of Atlantic Beach Jul� 10 ��I� APPLICATION NUMBER
Building Department (To be assigned by the Building Department.)
s 800 Seminole Road BY:-
Atlantic
Y'Atlantic Beach, Florida 32233-5445
Phone(904)247-5826 • Fax(904)247-5845
It E-mail: building-dept@coab.us Date routed:
City web-site: http:/Imvw.coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: (� .� a __ went review required Yes No
/ B u' .
Applicant: L/ T� �/l��S Planning &Zoni
v// '_ / / ree inistrator
Project: __/I IV /71L � 7ublic Works
ublic Uti i i
u is a ety
Fire Services
Review fee $ lC� Dept Signature �L
Other Agency Review or Permit Required Review or Receipt Date
of Permit Verified By
Florida Dept. of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS 00 V
Reviewing Department First Review: pproved. ❑Denied.
C
( ircle one.) Comments: f ,
BUILDING , �`-
d�
PLANNING &ZONING Reviewed by: Date: 1Q
TREE ADMIN. Second Review: ❑Approved as revised. [—]Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
i
I
i
Reviewed by: Date: _
Revised 05/14/09
k
® Lumber design values are in accordance with ANSI/TPI 1 section 6.3
These truss designs rely on lumber values established by others.
MiTek
V ,
RE: 131037- L27 5TH STREET
MiTek USA, Inc.
Site Information: �" ' ��� �K <..,<,..., 6904 Parke East Blvd,
Customer Info: Elite Homes Project Name: L27 Model: Tampa,FL 33610-4115
Lot/Block: Subdivision:
Address: 27 5th Street
City: Atlantic Beach State: FL
Name Address and License#of Structural Engineer of Record, If there is one,for the building.
Name: License#:
Address:
City: State:
General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FRC2010/TP12007 Design Program: MiTek 20/20 7.3
Wind Code: N/A Wind Speed: N/A mph Floor Load: 55.0 psf
Roof Load: N/A psf
This package includes 19 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
JSeal# (Truss Name Date No. Seal# Truss Name Date
11 IT4847426 11701 5/22/013 118 IT4847443 IFT02 5/22/014
2 IT4847427 (F02 15/22/013 119 I T4847444 I FT04 15�2/p�;,WING Rt�1EVU D '
13 I T4847428 I F03 15/22/013 1 for Coniormar=e"``'
drawings IS only
14 I T4847429 I F05 15/22/013 1 ReV1ew of shop tC'and does not relieve the contras o9
15 I T4847430 I F06 15/22/013 1 ATTENTION onaePt of the Proi the requirements of the shoe
15/22/013 1 all geld measurements.
16 �T4847431 I F07 the desrg {or any deviation e adv"
17 I T4847432 I F08 15/22/013 oI respo S61,11aa r shall determine a TION
to FpR CORREC
18 I T4847433 I F09 15/22/013 1 drawing RETURNED
19 I T4847434 I F11 15/22/0131 PPROVED RETURNED WITHOUT ACTION
110 IT4847435 I F12 15/22/013 1 p SEE TRAr.SM AE
11 I T4847436 I F13 15/22/0131 p APPROVED AS NOTED ETTE
112 I T4847437 I F14 15/22/013 ] p NOT AP ED COt1pnENTS
13 T4847438 I F15 15/22/013 1 ,
114 I T4847439 I F17 15/22/0131 FL C_RT 2596
X15 1 74847440 IF18 15/22/013 1 BV
HULSB G ENGINEERING 202
116 IT4847441 IF19 15/22/013 1 11481 ST.AUGUSTINE RD.
117 IT4847442 IFT01 15/22/013 I �pCKSONVtLLE,FL x2258
The truss drawing(s)referenced above have been prepared by MiTek %.%`� S'A,�
Industries, Inc. under my direct supervision based on the parameters ���O�•
•�G'E•Iv
provided by TrussMart Bldg Compts, LLC. ��.•' �- F•'•.'L�'�
Truss Design Engineer's Name: Albani, Thomas No 39380
My license renewal date for the state of Florida is February 28,2015.
IMPORTANT NOTE:Truss Engineer's responsibility is solely for ST TE OF
design of individual trusses based upon design parameters shown :0,�'•,�
on referenced truss drawings. Parameters have not been verified �'.,F •' O R �•'•�����
as appropriate for any use. Any location identification specified is0NA���
for file reference only and has not been used in preparing design.
Suitability of truss designs for any particular building is the
responsibility of the building designer, not the Truss Engineer, FL Cert. 6634
per ANSI/TPI-1, Chapter 2.
May 22,2013
Albani, Thomas 1 of 1
Job Truss Truss Type Qty Ply L27 STH STREET
T4847426
131037 F01 Floor Truss 1 1
Job Reference(optional) _
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10 412013 Page
ID:gVoiwQ2go WiR8NyrRf3A WJzDvx7-PCKBeh?ptOHCzGeye5FgDpDBmeRToW2je_sMJgzDve
0-4a 0.48
Scale=1:35.6
3x6 FP=
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
7 38
36 35 34 33 32 31 30 29 2a 27 26 25 24 23 22 21 20 19
3x3= 3x6 FP= 3x3=
21-1-0
21-1-0 —�
Plate Offsets X 1:Ed a 0-0.12 37:0-1-8 0-0-12 38:0-1-8 0-0-12
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.01 Vert(TL) n/a n/a 999
BCLL 0.0 Rep Stress Ina YES WB 0.03 Horz(TL) 0.00 19 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:111 Ib FT=0%F,0%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3(flat)
REACTIONS All bearings 21-1-0.
(lb)- Max Grav All reactions 250 lb or less at joint(s)36,19,35,34,33,32,31,29,28,27,26,25,24,23,22,21,
20
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES
1)All plates are 1.5x4 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
4)Gable studs spaced at 14-0 oc.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means. -�1j�1 111 A.
f>>!I
LOADCASE(S) Standard � ``+' . . A 44�f, I
0' ..\ ENS*-. 1 �'.
•. 1
.10 39380 '-
-STATE OF
'.,��'•.t p R 0•.•��,�.
SS�0 N A 1-E�.t��•
f�ttttt
FL Cert. 6634 I,
May 22,2013
Q WARNING-Veri design parameter-s an d RFAD MOTES ON TRIS AND INCLUDED M"'EK REFERETK B PAGE P9I 7473 BEFORE USE.
Design vol'xi for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown ,`
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity,of the M leR-
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1
fabrication,quality control,storage,derrvery,erection and bracing,consult ANSI/Tr11 Quality Criteria,DSB-89 and BCSI Building Componenl 5904 Parke East BIW.
solely Information vagqable from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria.VA 222314. Tampa,FL 33610-4115 11
If zt>utheerrl Pule SF}I1,rvn Laer i.;pec iti rl,lihls de-:sign vahresam_t'hcr4e effectirm 06/{11,(201.3 izy AL:"sf.
� • t
FJob Truss Truss Type Oty Ply L27 5TH STREET
F03 Floor Truss T4847428
—::
18 1
Job Reference o tional _
BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10:44 2013 Page
ID:9Voiw02goWR8NyrRf3AWJzDvx7-qn?KCi2hAJgmgjMWJDoXrSrZtrlO?mS9Ly51w?zDve
H 1 1-3-0—{ 1-7-0 0-��1{{a
Soa'f9=1:35.9
1.5x4 II
1.5x4
1.5x4= 44 = 1.5x4 11 3x8 FP= 44 = 1.5x4 =
1 2 3 4 5 6 7 8 9 10 11 12
4
25
—;Z!
23 22 21 20 19 18 17 16 15 14 13
34 = 44 = 300 MT20H FP= 1.5x4 11 44 = 3x6—
2-30 5.3-0 7-9-0 13-4-0 15.10.0 18-4-0 21-1-0
2-9-0 280 2-60 5-7-0 2-6-0 280 2-9-0
Plate Offsets X 1:Ed a 0-0-12 24:0.1-8 0-0-12 25:D-1-8 0.0-12
LOADING(psi) SPACING 2-0-0 CSI DEFL in (loc) '/de'
L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.66 Vert(LL) -0.20 16-17 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.76 Vert(TL) -0.32 16-17 >783 360 MT20H 187/143
BCLL 0.0 Rep Stress Incr YES WB 0.50 Horz(TL) 0.07 13 n/a n/a
BCDL 5.0 Code FRC201 OITP12007 (Matrix) Weight:125 Ib FT=0%F,O%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purfins, except
BOT CHORD 2x4 SP No.2(flat)*Except* end verticals.
13-20:2x4 SP SS(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3(flat)
REACTIONS (Ib/size) 23=1140/0-5-8 (min.0-1-8),13=1140/0-5-8 (min.0-1-8)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=1387/0,34=2347/0,4-5=-2935/0,5-6=-3161/0,6-7=-3161/0,7-8=-2939/0,
8-9=-2939/0,9-10=-2346/0,10-11=-1387/0
BOT CHORD 22-23=0/802,21-22=0/1953,20-21=0/2724,19-20=0/2724,18-1 9=0/3161,17-18=0/3161,
16-17=0/3126,15-16=0/2727,14-15=0/1952,13-14=0/802
WEBS 11-13=-1355/0,2-23=1354/0,11-14=0/1054,2-22=0/1054,10.14=-1018/0,3-22=-1021/0,
10-15=0/711,3-21=0/711,9-15=-687/0,4-21=678/0,9-16=0/382,4-19=0/477,
7-16=-375/0,5-19=-599/6,7-17=-241/412
NOTES
1)Unbalanced floor live loads have been considered for this design. ``%V111111111111
``t t t I I I r r rrrrr,
2)All plates are MT20 plates unless otherwise indicated.
3)All plates are 3x3 MT20 unless otherwise indicated. ,� p,S A. q /�
4)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. ,��Ol`+' .•• �e ''ice
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be �� .r •\ E INS•••. 9 'i
attached to walls at their outer ends or restrained by other means. /Q
LOAD CASE(S) Standard
NO 39380
'k • 4.
:O. -s TATE Uh.__ ;�4/J
/O .,C?��.
rrrrrlttt�t��
FL Cert. 6634
May 22,2013
it!dRNING-Yxrijy design parcmetera nn d RFAD NO TW ON THI S AND INCL UDED JUT EY REFEF-EIKE PAGE W1 74 T3 BFFORE USL.
Design valid for use only with MiTek connectors.This design is based only upon parameters shown.and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek'
erector.Additional permanent brocing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication.quality control,storage.delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety IMorm Ilion a/able from Truss Plate Institute,781 N.Lee Street,Suite 312.Alexandria,VA 2314. Tampa,FL 33610-4115
If
Sof*
pitre�5t3}Iumher >s ier.�erJ,the xte-.sign vahxnare t�ho.se effettivr-0603/3013 by ALK
-7:
Job Truss Truss Type pry Ply L27 5TH STREET
131037 F06 Floor Truss q 1
7T4847430
Job Reference(optional)
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10:46 2013 Page
ID:9Voiw02goWIR8NyrRf3AWJzDvx7-m974dO3yiwwU3lWvQer?wlwvGfz5TkPSoGa7 uzDve
0-1-8
F..I 13— 0 2-38
1
Sul -1:19.8
1.5x4 II
1.5x4 II
1.5x4= 3x3= 3x3= 1.5x4 II 3x3= 1.5x4=
1 2 3 4 53x3= B 7
1
15
I if
12 11 10 9
3x3= 3x3= 1.5x4 II 3x3,=-
3x6=
3,6=
11-9.8
11-9.8 -
Plate Offsets 1:Ed a 0-0-12 14:0-1-8 0 0 121,115:0-11-8.0-0-12]
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.67 Vert(LL) -0.11 11-12 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.75 Vert(TL) -0.15 11-12 >929 360
BCLL 0.0 Rep Stress Incr YES WB 0.22 Horz(TL) 0.01 8 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:72 Ib FT=0%F,0%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (Ib/size) 13=629/0-6-0 (min.0-1-8),8=629/0-5-8 (min.0-1-8)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=675/0,3-4=-946/0,4-5=-946/0,5-6=-674/0
BOT CHORD 12-13=0/432,11-12=0/887,10-11=0/946,9-10=0/946,8-9=0/421
WEBS 2-13=-728/0,2-12=0/439,3-12=-383/0,3-11=24/283,6-8=-710/0,6-9=0/455,
5-9=-494/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard `,` �PS'AIt
%
No 3938„Q
441
. ORI . �.
Iliffill
FL Cert. 663444
May 22,20 3
0 WARNING-Verify design parameters and READ ROTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MU 7473 BEFORE USE,
Design volld for use only with MiTek connectors.This design is based only upon parameters shown,and is for on individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the MiTek-
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSIITP11 Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information vor ble from Truss Plate Institute,781 N.Lee Street,Suite 312.Alexandria,VA 2314. Tempe,FL 33610-4115
If,
XIX)thein Pirtle SP lunt#ser i::yiecifie-d,0e Je_sign values are those etfectiw O6 tr7./2D1:3 by ALS£
Job Truss Truss Type Qty Ply L27 5TH STREET
T4847432
131037 F08 Floor Truss 1 1
Job Reference o banal
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10:48 2013 Page
ID:9VoiwQ2goW RBNyrRf3AWJzDvx7-iYF245CEYACJLgIY3tT?IOOvSgxxh11Fa3E3mzDv
°ta Oita
Sale=1:22.8
1 2 3 4 5 6 7 8 9 10 11 12
2 25
23 22 21 20 19 18 17 16 15 14 13
3x3= 30=
i 138-0
Plate Offsets X 1:Ed a 0-0-12 24:0-1-8 0-0-12 25:0-1-8 0-0-12
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.09 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.02 Vert(TL) n/a n/a 999
BCLL 0.0 Rep Stress Ina YES WB 0.03 Horz(TL) 0.00 13 n/a n/a
BCDL 5.0 Code FRC201 OfTPI2007 (Matrix) Weight:76 Ib FT=0%F,0%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 or bracing.
OTHERS 2x4 SP No.3(flat)
REACTIONS All bearings 13-8-0.
(lb)- Max Grav All reactions 250 Ib or less at joints)23,13,22,21,20,19,18,17,16,15,14
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES
1)All plates are 1.5x4 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
4)Gable studs spared at 1-4-0 or.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard
NO 39384
,s
FL Cert. 6634
May 22,20 3
WAPh7NG Vets design parameters and REALM NOTSS ON THIS AND INCLUDED IGTSX REFS ZFjWE PAGE AIII 7473 BEFORE USE.
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the MiTek
erector.Additional permanent bracing of the overall structure is the responsibility or the building designer.For general guidance regarding
fabrication.quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB•89 and SCSI Building Component 5904 Puke Fast EWA.
Safety Information va ble from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandria.VA/2314. Tempe,FL 33810.4115 —
IfSouthern Praw�Sp tuinher rs 4wcifieti,the rte.:ignvaluesare diose effective 0601{2013 by ALsc
t 0 46
FJob Truss Truss Type Oty Ply L27 5TH STREET
F11 Floor Truss q 1 T4847434
Job Reference nn,tional _
T BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16 10:50 2013 Page
ID:9Voiw02goWR8NyrRf3AWJzDvx7-fxNbTm6SmgQwYeggfUvx5j5cAGKPPXX1jtYL7fzDv
H L 1-3-0_� I-1� 0.1
Scale 1:23.1
1.5x4 II
1.5x4= 1.5x4 II 1.5x4
1 2
1.5x4
3 4 B 6 7 8
8 17
14 13 12 11 10
3x6 1.5x4 II -
3x6=
2-9-0 &5 0
Plate Offsets 2-9.0 5-&0 1 2-11-0 13-8-0
8-0
1:Ed a 0-0-12 16:0-1-8 0.0-iz 17:0-1-8 0-0-12
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.55 Vert(LL) -0.09 11-12 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.79 Vert(TL) -0.1311-12 >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.27 Horz(TL) 0.02 9 n/a We
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:84 Ib FT=0%F,O%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (Ib/size) 15=732/0-5-8 (min.0-1-8),9=732/0-5-8 (min.0-1-8)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=809/0,3-4=-11299/0,4-5=1299/0,5-6=-1228/0,6-7=-818/0
BOT CHORD 14-15=0/505,13-14=0/1106,12-13=0/1299,11-12=0/1299,10.11=0/1119,9-10=0/501
WEBS 7-9=-844/0,2-15=-852/0,7-10=0/572,2-14=0/548,6-10=-543/0,3-14=-536/0,
6-11=0/259,3-13=0/465,5-11=-272/37
NOTES
1)Unbalanced floor live loads have been considered for this design.
';2)All plates are 3x3 MT20 unless otherwise indicated.
3)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1 Od(0.131"X 3")nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means.
LOAD CASE(S) Standard �� p'S l A q`--.,,
0 �G•E N.4
NO 39380
F .
8 ATE Vit. 111:
OR k
ss/0N
N A`E-
III
FL Cert. 6634
May 22,20 3
AWARA7NG Verify design parameters and READ NOTES ON THIS AND INC'4UDED MTTEKRF,FFJ?BW.BPAGE P91 7473 BEFORE t7SE.
Design valid for use only with MiTek connectors.This design is based only upon parometers shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the ��T�k,
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East Blvd.
Sdety Information vP ble from Truss Plate Institute,781 N.Lee Sheet,Suite 312.Alexandria,VA 2314. Tempe,FL 33810-4115
if
Sratit.hern Pine�8 lumTr-r is Weci ied,the de:cign vaiur_sare fihrxse,effective_0501./2013 by ALSL
Job Truss Truss Type City Ply L27 5TH STREET
T4847436
131037 F13 FLOOR TRUSS 5 1
Job Reference aptlonall
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 2216:10:52 2013 Page
ID:9Voiw02go W R8NyrRf3AWJzDvx7-bJULuRBilmgeny_3nvyPABAxN44_tOkKAB1 SCXzDve
1-0-8 1-2-0 1-3-0 0,1 a
I--r Scale=1.14.9
1.5x4 I 3x3= 3x3 11 1.5x4 11
1 2 3 3x3= 4 57x6— 6
12
1.5x4 = q
N
11 10 9 7
1.5x4 II 1.5x4 II 3x8 =
3x3 = 7z6 =
4-2-8
3-11-81- 5.10-0
3.11-8 0.1- i 1-74
6-1.8
Plate Offsets X 1:Ed a 0.0-12 12:0-1-8 0-0-12
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.63 Vert(LL) 0.02 8-9 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.46 Vert(TL) 0.03 8-9 >999 360
BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(TL) -0.00 8 n/a n/a
BCDL 5.0 Code FRC201 O/TPI2007 (Matrix) Weight:47 lb FT=0%F,0%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-10-0 oc pudins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (Ib/size) l l=-12/Mechanical,8=1052/0-6-0 (min.0-1-8)
Max Uplift I=-166(LC 4)
Max Grav 11=151(LG 3),8=1052(LC 1)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 7-12=-480/0,6-12=-480/0,3-4=0/483,4-5=0/483
BOT CHORD 7-8=-346/0
WEBS 2-11=-85/358,3-8=-594/0,5-7=0/612,5-8=-689/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s)for truss to truss connections.
3)Provide mechanical connection(by others)of truss to bearing plate Capable of withstanding 166 Ib uplift at joint 11.
4)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. `11111 I i ill
5)Recommend 2x6 to walls at theiracks,on outerendsdorrestrained by other means,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be `p`PS A q�i,
attached
6)CAUTION,Do not erect truss backwards. ,��0`v` ,.•••• �Q �j�
LOAD CASE(S) Standard : x,
1)Floor:Lumber Increase=1.00,Plate Increase=1.00 3938Q
Uniform Loads(plf) _� k ✓ f,
Vert:7-11=-10,1-6=-100
Concentrated Loads(lb) '
Vert:6=425
: r 1• ATE Ui�� :�✓:•111
, O 1
•,�S'S/d N Ay�����•
FL Cert. 6634
May 22,20 13
0 WARNING.yerif design pararrld ers and READ NOTES ON 77115 AND INCLUDED PHT'EK REFFRETKE PAGE MTF 7473 BEFORE(TSE.
Design valid for use only with MiTek connectors.This design is based only upon parameters shown.and is for on individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibility of the MiTek
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication.quality control,storage,delivery,erection and bracing.consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East BNd.
Sol IMormal on a' ble from Truss Plate Institute,781 N.Lee Sheet,Suite 312.Alexandria.VA 2314. Tamps,FL 33610-4115
If
Stauthern pine�Sp Futntter is specified,the.design values are those effective 04'r/01.112013 IN ALSO.
Job Truss Truss Typeply ply L27 5TH STREET
T4847438
131037 F15 Floor Truss 2 1
Job Reference(optional) _
TRUSSMART BUILDING COMPONENTS, Midway,GA,31320 7.350 a Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10:54 2013 Page
ID:9VoiwQ2goWl R8NyrRf3A WJzDvx7-Xic6179zgNwM 1 G7R uK_tFZGPpttRLOFdeV WYGQzDve
0"
1 2 3 4 Scale=1:13.0
9 10
N
8 7 6 5
3x3= 30 =
4-2-0
4-2-0
Plate Offsets X 1:Ed a 0-0-12 9:0-1-s D-0-12 10:0-1-a 0-0-12
LOADING(pyo SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.02 Vert(TL) n/a n/a 999
BCLL 0.0 Rep Stress Ina YES WB 0.03 Horz(TL) 0.00 5 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:27 Ib FT=0%F,0%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 4-2-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3(flat)
REACTIONS All bearings 4-2-0.
(lb)- Max Grav All reactions 250 Ib or less at joint(s)8,5,7,6
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES
1)All plates are 1.5x4 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
4)Gable studs spaced at 14-0 oc.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be
attached to walls at their outer ends or restrained by other means. `t`�11
LOAD CASE(S) Standard 00� ,S. A. q
.`�,'r�•�,�GE. SF��,��'
f
N10 39380 '
0.. NATE (fir :1t✓
,�• c P �.
FL Cert. 6634
May 22,20 13
0 WARNING Verify design parameters and READ MMES ON THIS AND INCLUDED AUTEK REFERENCE PAG£11II 7473 BEFORE(1&E.
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity,of the MiTek
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery.erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East BW.
Salety Information vo able from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria.VA 2314. Tampa,FL 33610-4115
if
Southern Pince, lumber i:ss iecifierl,the de-.mV vahnes are Phase etlectiwe OFr 03(2t1i3 by ALAC,
i V �
JobTruss Truss Type
aY Ply L27 5TH STREET
131037 F18 Floor Truss T4847440
1 1
Job Reference a tional
TRUSSMART BUILDING COMPONENTS. Midway,GA,31320 7.350 s Sep 26 2012 MiTek Industries,Inc. Wed May 22 16:10:56 2013 Page
ID:9Voiw02goVMRBNyrRf3AWJzDvx7-T5ksjpBDL?A4GZHg010LK Lf7hSRpDxw5p?fLlzDv
a1-a
H 1 1--3-0 i 0-7-0 1-2-0
i 1-7-0 1 0-1 a
Stale=1.27.3
1.5x4 I 1.5x4
1.5x4= 4x4=
1.5x4=
1 2 3 4 5 8 7 8 9 10 11
3
24
22 20 19 18 17 1s 14 13
3x6= 4x8= 1.5x4 II 3x8 FP= 3x6= 1.5x4 II 1.5x4 II 3x8=
1.5x4 II
2-2-8
1-11-8 2-1i0 4-10-0 6-9-9 114-8
1-11-8 0-14 2-74 -� 3-110 2-7-8 46.1-
0-1-8
Plate Offsets 1:Ed a 0-0-12 23:0-1-8 0-0-12 24:0-1-8 0-0-12
LOADING(psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.45 Vert(LL) -0.03 16-18 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.49 Vert(TL) -0.05 16-18 >999 360
BCLL 0.0 Rep Stress Ina YES WB 0.34 Horz(TL) 0.01 12 n/a n/a
BCDL 5.0 Code FRC20101TP12007 (Matrix) Weight:110 Ib FT=0%F,C%E
LUMBER BRACING
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (Ib/size) 21=1366/0-6-0 (min.0-1-8),12=203/0-3-8 (min.0-1-8),15=680/0-6-0 (min.0-1-8)
Max Grav21=1366(LC 3),12=248(LC 11),15=763(LC 13)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 22-23=-575/0,1-23=575/0,2-3=0/671,3-4=0/672,4-5=-346/373,5-6=-523/210,
6-7=-421/115
BOT CHORD 21-22=-406/0,20-21=511/174,19-20=-210/523,18-19=-210/523,17-18=-210/523,
16-17=-210/523,15-16=-71/300
WEBS 2-22=0/718,2-21=-747/0,7-15=-540/0,4-21=-685/0,4-20=0/422,5-20=-460/0,
9-15=-365/0
NOTES
1)Unbalanced floor live loads have been considered for this design.
2)All plates are 3x3 MT20 unless otherwise indicated.
3 end fixity model was used in the analysis {{{{1111/1
4)Recommend)26 st ongbacksnonhedge,spaced rat 10-0-0 oc and fastened to each truss with 3nd 1 Od(0. 31"X 3')esign of this snails. Strongbacks to be ON,
4) A.
attached to walls at their outer ends or restrained by other means. ��c) ,.•••• �g ��
5)CAUTION,Do not erect truss backwards. ``�� ••.��C E N SF. S7 �i�
LOADCASE(S) Standard
NO 39380
1)Floor:Lumber Increase=1.00,Plate Increase=1.00 k •• ".
Uniform Loads(plf) A
Vert:12-22=-10,1-11=-100
Concentrated Loads(lb) d=
Vert:1=520
-�'.• STAT E U% IL:
A`
FL Cert. 6634
May 22,20 13
A WARMNG-Verify design parameters and READ NOTES ON 77115 AND 1hrLUDE0 JffTEK REFERENCE PAGE 1191 7473 BEFORE M.E
Design valid for use only with MiTek connectors.This design is based only upon parameters shown,and is for on individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the MiTek
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding
fabrication,quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSII and SCSI Building Component 6904 Parke East BW.
Solely Information va able from Truss Plate Institute,781 N.Lee Street.Suite 312,Alexandria.VA 2314. Tempe,FL 33610-4115
If Southern pine1SP 1writwr is specified,the design vak care t'hlase effective Of'r/01/3£31.3 by ALSO
4 M �
Job Truss Truss Type Qty Ply L27 5TH STREET
131037 FT01 Floor Truss 1 n
L Reference(optional) 74847442
TRUSSMART BUILDING COMPONENTS,Midway,GA,31320,Hampton Inn 7.350 s Sep 26 2012 Mi7ek Industries,Inc.Wed May 22 16:18:13 2013 Page 1
ID:9VoiwQ2goW RBNyrRf3AWJzDvx7-v5wjOb9lUDlvg8gvmBspo7xMHrcQivRFaIMHATzDvXu
2-0-0
Scale=122.7
1.5x4 II 1.5x4 I
1 13 2 14 15 3 4 16 17 5 6
F1 F1
Z-7
Li
11 10 9 8
1.5x4 11 1.5x4 11
17_8-0
13-8-0
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.43 Vert(LL) -0.04 8-9 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.45 Vert(TL) -0.05 8-9 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.13 Horz(TL) 0.02 7 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:142 Ib FT=0%
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (Ib/size) 12=982/0-3-8 (min.0-1-8),7=980/0-3-8 (min.0-1-8)
Max Grav 12=1139(LC 3),7=1146(LC 4)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-14=1713/0,14-15=-1713/0.3-15=-1713/0,3-4=-2085/0,4-16=-1783/0,16-17=-1783/0,5-17=-1783/0
BOT CHORD 11-12=0/1296,10-11=0/2085,9-10=0/2085,8-9=0/2085,7-8=0/1407
WEBS 2-12=1633/0,2-11=0/682,3-11=-725/0,5-7=-1794/0,5-8=0/627,4-8=-637/0
NOTES
1)2-ply truss to be connected together with t Od(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2x4-1 row at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced floor live loads have been considered for this design.
4)All plates are 3x4 MT20 unless otherwise indicated. ♦ J A
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. �� _p P` •,
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks `moi� `• G E N S•L• 9 i
to be attached to walls at their outer ends or restrained by other means. �C •,
7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)199 Ib down at 1-5�,131 Ib ••�' i
down at 3-5-4,131 Ib down at 5-5-4,131 Ib down at 7-54,131 Ib down at 9-5-4,and 131 Ib down at 10-3-12,and 199 lb down at N 0 39380
11-5-4 on top chord. The design/selection of such connection device(s)is the responsibility of others. * s
LOAD CASE(S) Standard rj
1)Floor:Lumber Increase=1.00,Plate Increase=1.00 "j j ATE -r.
Uniform Loads(plf)
Vert:7-12=-10,1-6=-100
Concentrated Loads(lb) �iO��•�< 0 R ,O P
Vert:5=-119(F)4=-51(F)13=-119(F)14=-51(F)15=-51(F)16=-51(F)17=-51(F) �j S'�••••..•••••
0 N A`E 0
I
FL Cert. 663
May 22,2013';
err esrgn pca era an - .
Design valid for use only with MTek connectors.This design is based only upon parameters shown,and is for an individual building component.
ApplicoUlity of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown �L
is for lateral support of individual web members only.Additional temporary bracing to insure stability during construction is the responsibillity of the M)Tpik
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding 1
fabrication.quality control,storage,delivery,erection and bracing,consult ANSIM11 Quality Criteria,OSB-89 and III Building Component 6904 Parke East Blvd.
Solely IMormalbn 51vo able from Truss Plate Institute.781 N.Lee Street.Suite 312,Alexandra,VA 2314. Tempe,FL 33610-4115
If Southerrl Pule{Sp lurnkwr is Wecifie ll,the deOgn vatur-s;we those effective r 01/3013 by ALSO
r
Job Truss Truss Type Qty Ply J-175TH STREET
131037 Frus Floor Truss 1
74847444
L ob Reference o tional
TRUSSMART BUILDING COMPONENTS,Midway,GA,31320,Hampton Inn 7.350 is Sep 26 2012 MiTek Industries,Inc.Wed May 22 16:20:54 2013 Page 1
ID:9VoiwQ2goWIR8NyrRf3AWJzDvx7-i38bBe61Zha3VtesiSFZp46vekbLwklxcssJKezDvVN
2-0-0 0-7-6_I
Scale=1:19.6
I
1.5x4 II 3x4 = 1.5x4 II 3x4 = 1.5x4 11
1 2 3 4 3x4 =
5 6
10 9 8
3x4= 1.5x4 II 3x4 =
3,4=
3x4=
11-a�1
11-9-8 — ---�
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.23 Vert(LL) -0.02 8-9 >999 480 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.30 Vert(TL) -0.03 8-9 >999 360
BCLL 0.0 Rep Stress Incr NO WB 0.08 Horz(TL) 0.01 7 n/a n/a
BCDL 5.0 Code FRC2010/TPI2007 (Matrix) Weight:123 Ib FT=0
LUMBER BRACING
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (Ib/size) 11=725/0-3-8 (min.0-1-8),7=725/0-3-8 (min.0-1-8)
FORCES (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-3=-1207/0,3-4=1207/0,4-5=-1053/0
BOT CHORD 10-11=0/760,9-10=0/1207,8-9=0/1207,7-8=0/816
WEBS 2-11-952/0,2-10=0/582,5-7=-1033/0,5-8=0/312
NOTES
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2x4-1 row at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to
ply connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced floor live loads have been considered for this design.
4)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. ��111111(111
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks
to be attached to walls at their outer ends or restrained by other means.
LOADCASE(S) Standard `��.�,•..�\GENSF•,
1)Floor:Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf) IN 0 39380
Vert:7-11=-1 0,1-6=-118
. - - b'fATE Ui-_ i
I
FL Cert. 6634
May 22,2013
WAKMvia vmfy design parametem andPAGE LK
�- -------
Desi n valid for s only with MiTek g use y e connectors.This design a based only upon parameters shown,and is for an individual building component.
Applicability of design parameters and proper incorporation of component is responsibility of building designer-not truss designer.Bracing shown
is for lateral support of individual web members only.Additional temporary bracing to insure stability during constructionits the responsibillity of the
erector.Additional permanent bracing of the overall structure is the responsibility of the building designer.For general guidance regarding MiTek
fabricationr quality control,storage,delivery,erection and bracing,consult ANSI/TPII Quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East BIM.
Safety Irdonnatlon G a'oble from Truss Plate Institute,781 N.Lee Street,Suite 312,Alexandra.VA X2314. Tampa,FL 33610-4115
If MAthern Pirie{SP linntmf*i;speci ierl.,rho.design values ane those et�c,tivr_0610.../20]_3 4 ALS[
JANUARY 1, 2009 STANDARD RIBBON BLOCK DETAIL ST-RIBBON
® MiTek USA,Inc. Page 1 of 1
aaaa
0 00
0 00
MiTek USA,Inc.
z z
v
T T
T
FASTEN RIBBON BLOCK TO END VERTICAL WITH FASTEN RIBBON BLOCK TO END VERTICAL WITH
TWO ROWS OF 10d NAILS(.120"DIA.X 3")SPACED TWO ROWS OF 10d NAILS(.120"DIA.X 3")SPACED
4"O.C.(USE THREE NAILS MINIMUM) 4"O.C.(USE THREE NAILS MINIMUM)
JANUARY 1, 2009 STANDARD DETAIL FOR ALLOWING A DECK ST-DECK LEDGR
LEDGER CONNECTION TO A FLOOR TRUSS
I�laa U MiTek USA,Inc. Page 1 of 1
0 00
Lm-u
O 00
In
MiTek USA, Inc.
LADDER TRUSS WITH 4X2 SPF NO.2
MINIMUM CHORD LUMBER,WEBS SHALL
2x4 BANDBE 04 STUD HF,SPF,DF OR SYP AT
16"O.C.MAX.
DOUBLE END FASTENER(S)SPECIFIED
BY OTHERS
VERTICAL -\1 1 770
FLOOR BLOCKING PER
BUILDING DESIGNER
FASTENER(S)SPECIFIED LEDGER SPECIFIED
BY OTHERS.
BY OTHERS
O
LEDGER SPECIFIED c p.
BY OTHERS FLOOR TRUSSES
p 24"O.C.MAX.
TYPICAL FLOOR p
TRUSS LADDER FRAME BE
SU
CONTINUOUSLY SUPPORTED
BEARING AT
END OF TRUSS
FLOOR TRUSS PERPENDICULAR FLOOR TRUSS PARALLEL
TO BEARING WALL TO BEARING WALL
N.T.S. N.T.S.
OTHER FRAMING ELEMENTS OTHER FRAMING ELEMENTS
NOT SHOWN FOR CLARITY NOT SHOWN FOR CLARITY
NOTES:
DETAIL PERMITS A MAXIMUM OF TWO 1/2"DIA.THRU BOLTS OR LAG SCREWS TO BE INSTALLED ALONG THE VERTICAL CENTER LINE AND
INTO THE DOUBLE END VERTICAL OF FLOOR TRUSSES OR INTO THE 4X4 VERTICALS OF A LADDER TRUSS.
FASTENERS SHALL NOT INTERFERE WITH ANY JOINTS OR CONNECTORS WITHIN THE FLOOR OR LADDER TRUSS AND BE INSTALLED
PER NDS.
CAPACITY OF CONNECTION SHALL BE SPECIFIED BY THE BUILDING DESIGNER.REFER TO NATIONAL,STATE,LOCAL BUILDING CODES
OR STANDARD INDUSTRY DETAILS APPROVED BY THE BUILDING OFFICAL.
DETAIL HAS CONSIDERED VERTICAL LOAD CAPACITY OF THE FASTENERS ONLY.ALL OTHER FRAMING ELEMENTS REQUIRED TO
SUPPORT AND OR RESIST ANY OTHER LOADS AND OR FORCES SHALL BE THE RESPONSIBILITY OF OTHERS.
DESIGN OF ALL DECK OR PORCH COMPONENTS SHALL BE BY OTHERS.
JANUARY 1, 2009 STANDARD DETAIL FOR ATTACHING A LEDGER ST-LEDGR
TO THE SIDE OF A FLOOR TRUSS GABLE
MiTek USA,Inc. Page 1 Of 1
O 00
O OD
MAX.WALL LOAD=800 PLF
MiTek USA,Inc.
FLOOR GABLE TRUSS WITH SPF NO.2
MINIMUM OP CHORD LUMBER. FLOOR TRU S
MAX LOAD ON LEDGER=480 PLF
HEATHING
14,
DEPTH=14",
16",18",OR 20"
SHEA HING
04 STUDS AT 16"SPACING MAX.
BRG.WALL (HF,SPF,DF,OR SYP)
A ACH LEDGER(DESIGNED BY OTHERS)WITH TWO 1/2"DIAMETER
ASTM A307 BOLTS WITH WASHERS AT EACH STUD LOCATION.
(MINIMUM 2X8 SPF NO.2)
7
iwO
o act' o 0
34-10-00 0 ° o w'o
C N G Y v A I FO
13-08-00 R O
R R E1A��d
f O o
v m anm�O a N
R 9�Y�u'cu'S
a 45
N�
O - R ' o 'Ili45 io m o J
9 N V C Y 2 O a�0 w0 M
.Z LD Y W Nw W li
0 -a
I,N v. C rn 03
N�acc w �
W 6a. ` :.
° Y CC d�s w O Q
o I!m Im
p a
LL ILL ,LLO��
O � E N 2
d3 'N d 017: 2 p ru~_
p
Y C t d� Y 2
oa N"«v 20:5'-28 E
u f
C m LOi I� B� 'o c • �z
E Or-LU
�.�cy�'m ��
j I 7 AO 2 3o YA 72
aVO=C
0°1^ 0
" wZ 1,
0.
mo'ma ° °c 2 0)
l 7 N G N C.L f,Ug 0 CLN_n>��.,G O Q Q
R O N YY—Y I2 d N�� 11 LL
N N A#a jw C 5 O g O W
N E U 'U
CO°c
c 2 iom�3N:0C°1 Xw
r. mwdQo4 o C M'%RR N d" Y m
NNN NN N N C
1 I I °oa°0y c
jr % �� u CS m i1n ri°p�s Ch
Es uwi
I jI j / \ j' A p �„Vly °N C m C a K
F
0 o I o 0 0 0 0mU.m`2 '= E•2Av No~>
LL LL LL LL LL LL �'
j ILL I� ��' f- vD a OZ
QO Q
r.
b
i
4 II I
--__—? -_I
o
-F12m
F12
F12 c u V
F2 N R LU �j ZN CI
m m m
r co
06 L
o
F11 0 •� QI
—T—
yA y L
oA O 0) O
N O 00 O
F11 j C f/; "t O tC)
j gaANS �� 4 co �
1 v N E E�N W (7 pp l� �t
j I Q Y E w 2 U Q 00 .-.00
I N ANrYV��OCC /I"1 Rooco
�LL LL LL_ LL_�I LL LL LL� Aq CCY f4 r' co
co N
3-03-M 7-02-00 3-O3 08 7-0&4)0 ^N 9 pt 3LL
��1�G'
34-10.00 3 3
E ` ` -j "' — LL
FrF I L-
:EC OPY
Residential System Sizing Calcul
Summary
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M)
Humidi data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r.
Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F
Winter setpoint 70 F Summer setpoint 75 F
Winter temperature difference 38 F Summer temperature difference 18 F
Total heating load calculation 48066 Btuh Total cooling load calculation 42783 Btuh
Submitted heating capacity %of calc Btuh Submitted cooling capacity %of calc Btuh
Total (Electric Heat Pump) 99.9 48000 Sensible(SHR = 0.72) 109.7 34800
Heat Pump+Auxiliary(O.OkW) 99.9 48000 Latent 119.4 13200
Total Electric Heat Pum 112.2 48000
WINTER CALCULATIONS
Winter Heating Load for 3523 sqft)
Load component LoadVNrMows(16%)
Window total 593 sqft 7881 Btuh
Wall total 3722 sqft 10929 Btuh ntll.c32%)
Door total 72 sqft 1255 Btuh CeilingsQ%)
Ceiling total 1919 sqft 3489 Btuh
Floor total See detail report 9277 Btuh
Infiltration 365 cfm 15236 Btuh
Duct loss 0 Btuh Doors( %) Wans(23%)
Subtotal 48066 Btuh
Ventilation 0 cfm 0 Btuh Floors(19%)
TOTAL HEAT LOSS 48066 Btuh
SUMMER CALCULATIONS
Summer Cooling Load for 3523 sqft)
Load component Load
Window total 593 sqft 14505 Btuh
Wall total 3722 sqft 5867 Btuh
Door total 72 sqft 958 Btuh
Ceiling total 1919 sqft 2204 Btuh
Floor total 205 Btuh )
Infiltration 274 cfm 5413 Btuh
VNrrciurvs(34%)
Internal gain 2580 Btuh
Duct gain 0 Btuh
Sens.Ventilation 0 cfm 0 Btuh
Blower Load 0 Btuh Intil.(36%)
Total sensible gain 31731 Btuh
Latent gain(ducts) 0 Btuh
Latent gain(infiltration) 9852 Btuh cell:,ys(s%)
Latent gain(ventilation) 0 Btuh Dpi) VVM.(14%)
Latent gain(internal/occupants/other) 1200 Btuh
Total latent gain 11052 Btuh
TOTAL HEAT GAIN 1 42783 Btuh
Digitally signed by Timothy D.
EnergyGaugeO SysI Ga-er
ldthy D. DN CN=Timothy D Ga dner, _
PREPARED BY: us o=usnHeas
8th Edition —Ixeason:I attest to the accuracy
DATE:�a rd n e r and inleg N/d this document
Date:2013.06.03 14:49:47-04'D r
EnergyGauge®/USRRZB 0.1
Residential Window Diversity
MidSummer
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
Weather data for: Jacksonville -Defaults
Summer design temperature 93 F Average window load for July 6040 Btuh
Cooling setpoint 75 F Peak window load for July 7205 Btuh
Summer temperature difference 18 F Excusion limit(130% of Ave.) 7852 Btuh
Latitude 30.5 North I Window excursion (July) None
WINDOW Average and Peak Loads
9000.00-
8000.00 Limit for excursion
7000.00
r 6000.00 12 Hour Average-,
M
5000.00
0
J �
'0 4000.00
c
3000.00-
2000.00 -
1000.00-
0.00
000.002000.001000.000.00
8 a.m. 10 12 2 p.m. 4 p.m. 6 p.m. 8 P.M.
a.m.
Total July Window Load(Radiation and conduction)
The midsummer window load for this house does not exceed the window load excursion limit.
This house has adequate midsummer window diversity.
EnergyGauge®System Sizing for Florida residences only
PREPARED BY:
DATE: 10
EnergyGauge®/USRRZB 0.1
Residential Window Diversity
October
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
Weather data for: Jacksonville - Defaults
Summer design temperature 93 F Average window load for October 6540 Btuh
Cooling setpoint 75 F Peak window load for October 9618 Btuh
Summer temperature difference 18 F Excusion limit(130%of Ave.) 8502 Btuh
Latitude 30.5 North I Window excursion (October) 1116 Btuh
WINDOW Average and Peak Loads
10000.00
9000.00
Limit for excursion
8000.00
7000.00 12 Hour Average
L
6000.00
a
J 5000.00
0
4000.00
3000.00 -
2000.00 -
1000.00 .
000.002000.001000.00
0.00
8 a.m. 10 12 2 p.m. 4 p.m. 6 p.m. 8 p.m.
a.m.
Total October Window Load(Radiation and conduction)
Warning:This application has glass areas that produce relatively large heat gains for part of the day. Variable
air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system
may be required or some rooms may require zone control.
EnergyGauge®System Sizing for Florida residences only
PREPARED BY:
DATE:
EnergyGauge®/USRRZB v3.1
System Sizing Calculations - Winter
Residential Load - Room by Room Component Details
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000 Building Type: User
6/3/2013
Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F(MJ8 99%)
Component Loads for Room#1: 1st Floor
Window Panes/Type Frame U Orientation Area s ft X HTM= Load
1 2, NFRC 0.30 Vinyl 0.35 N 34.0 13.3 452 Btuh
2 2, NFRC 0.30 Vinyl 0.35 N 5.4 13.3 72 Btuh
3 2, NFRC 0.30 Vinyl 0.35 N 34.0 13.3 452 Btuh
4 2, NFRC 0.30 Vinyl 0.35 E 17.0 13.3 226 Btuh
5 2, NFRC 0.30 Vinyl 0.35 E 16.0 13.3 213 Btuh
6 2, NFRC 0.30 Vinyl 0.35 E 21.3 13.3 284 Btuh
7 2, NFRC 0.30 Vinyl 0.35 S 21.3 13.3 284 Btuh
8 2, NFRC 0.30 Vinyl 0.35 S 96.0 13.3 1277 Btuh
9 2, NFRC 0.30 Vinyl 0.35 W 68.0 13.3 904 Btuh
Window Total 313.1 s ft 4164 Btuh
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
1 Frame-Wood - Ext (0.077) 19.0/0.0 130 2.94 382 Btuh
2 Frame-Wood -Ext (0.077) 19.0/0.0 60 2.94 175 Btuh
3 Frame-Wood -Ext (0.077) 19.0/0.0 131 2.94 385 Btuh
4 Frame-Wood -Ext (0.077) 19.0/0.0 596 2.94 1750 Btuh
5 Frame-Wood -Ext (0.077) 19.0/0.0 361 2.94 1059 Btuh
6 Frame-Wood - Ext (0.077) 19.0/0.0 736 2.94 2161 Btuh
Wall Total 2013 s ft 5911 Btuh
Doors Type Storm Ueff. Area X HTM= Load
1 Insulated- Exterior, n (0.460) 24 17.5 420 Btuh
2 Insulated- Exterior, n (0.460) 18 17.5 311 Btuh
Door Total 42 s ft 73013tuh
Floors Type Ueff. R-Value Size X HTM= Load
1 Slab On Grade (1.180) 0.0 193.5 ft(perim.) 44.8 8677 Btuh
Floor Total 1604 s ft 8677 Btuh
Room Envelope Subtotal: 19482 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.60 19248 0.54 197.3 8241 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DLM of 0.000) 0 Btuh
Room#1 Sensible Room Subtotal 27723 Btuh
EnergyGauge®/USRRZB v3.1 Page 1
Manual J Winter Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000 Building Type: User
6/3/2013
Component Loads for Room#2:2nd Floor
Window Panes/Type Frame U Orientation Area(sqft) X HTM= Load
10 2, NFRC 0.30 Vinyl 0.35 N 20.0 13.3 266 Btuh
11 2, NFRC 0.30 Vinyl 0.35 N 15.1 13.3 201 Btuh
12 2, NFRC 0.30 Vinyl 0.35 N 30.2 13.3 402 Btuh
13 2, NFRC 0.30 Vinyl 0.35 E 45.3 13.3 603 Btuh
14 2, NFRC 0.30 Vinyl 0.35 E 16.0 13.3 213 Btuh
15 2, NFRC 0.30 Vinyl 0.35 E 8.0 13.3 106 Btuh
16 2, NFRC 0.30 Vinyl 0.35 S 45.3 13.3 603 Btuh
17 2, NFRC 0.30 Vinyl 0.35 S 21.0 13.3 279 Btuh
18 2, NFRC 0.30 Vinyl 0.35 W 8.0 13.3 107 Btuh
19 2, NFRC 0.30 Vinyl 0.35 W 60.4 13.3 804 Btuh
20 2, NFRC 0.30 Vinyl 0.35 W 10.0 13.3 133 Btuh
Window Total 279.5(sqft) 3717 Btuh
Walls Type Ornt. Ueff. R-Value Area X HTM= Load
(Cav/Sh)
7 Frame-Wood -Ext (0.077) 19.0/0.0 135 2.94 395 Btuh
8 Frame-Wood -Ext (0.077) 19.0/0.0 108 2.94 316 Btuh
9 Frame-Wood -Ext (0.077) 19.0/0.0 565 2.94 1660 Btuh
10 Frame-Wood - Ext (0.077) 19.0/0.0 261 2.94 765 Btuh
11 Frame-Wood - Ext (0.077) 19.0/0.0 589 2.94 1728 Btuh
12 Frame-Wood - Ext (0.077) 19.0/0.0 52 2.94 153 Btuh
Wall Total 1709(sqft) 5018 Btuh
Doors Type Storm Ueff. Area X HTM= Load
3 Insulated- Exterior, n (0.460) 20 17.5 350 Btuh
4 Insulated - Exterior, n (0.460) 10 17.5 175 Btuh
Door Total 30(sqft) 52413tuh
Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load
1 Unvent Attic/L/Shing (0.048) 1.0/19.0 1919 1.8 3489 Btuh
Ceiling Total 1919(sqft) 3489Btuh
Floors Type Ueff. R-Value Size X HTM= Load
2 Interior (1.180) 0.0 1604.0 sqft 0.0 0 Btuh
3 Raised-Open (0.050) 19.0 315.0 sqft 1.9 600 Btuh
Floor Total 1919 sqft 600 Btuh
Room Envelope Subtotal: 13348 Btuh
Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM=
Natural 0.60 17271 0.46 167.5 6995 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DLM of 0.000) 0 Btuh
Room#2 Sensible Room Subtotal 20343 Btuh
EnergyGaugeO/USRRZB v3.1 Page 2
Manual J Winter Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000 Building Type: User
6/3/2013
SYSTEM GROUPS (BLOCK LOADS)
Heating Loads
For System(s):1 Block load 27723 Btuh
Serving Rooms: 1
Heating Loads
For System(s):2 Block load 20343 Btuh
Servina Rooms: 2
HOLE HOUSE TOTALS
Subtotal Sensible Heat Loss 48066 Btuh
Totals for Heating Ventilation Sensible Heat Loss 0 Btuh
Total Heat Loss 48066 Btuh
EQUIPMENT
1. Electric Heat Pump # 24000 Btuh
2. Electric Heat Pump # 24000 Btuh
Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values)
or-Glass as'Clear or'Tint'(Uses U-Factor and SHGC defaults)
U-(Window U-Factor)
HTM-(ManualJ Heat Transfer Multiplier) 10
Version 8
EnergyGaugeO/USRRZB v3.1 Page 3
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Elite Homes Inc. Project Title:
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
Reference City:Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr.
Component Loads for Room#1: 1st Floor " . .
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U InSh IS Ornt Len H t Gross Shaded Unshaded Shaded_ Unshaded
1 2 NFRC 0.30,0.35 No No N B.Oft 1.Oft 34A OA 34.0 13 13 427 l3tuh
2 2 NFRC 0.30,0.35 No No N 10.Of 2.5ft 5.4 0.0 5.413 13 68 Btuh
3 2 NFRC 0.30,0.35 No No N 2.Oft 5.Oft 34.0 0.0 34.0 13 13 427 Btuh
4 2 NFRC 0.30,0.35 No No E 2.Oft 12.Of 17.0 0.0 17.0 13 35 598 Btuh
5 2 NFRC 0.30,0.35 No No E 2.Oft 3.Oft 16.0 0.0 16.0 13 35 562 Btuh
6 2 NFRC 0.30,0.35 No No E 2.Oft 12.Of 21.3 0.0 21.3 13 35 750 Btuh
7 2 NFRC 0.30,0.35 No No S 11.3f 2.Oft 21.3 21.3 0.0 13 15 268 Btuh
8 2 NFRC 0.30,0.35 No No S 11.3f 2.Oft 96.0 96.0 0.0 13 15 1207 Btuh
9 2 NFRC 0.30,0.35 No No W 2.Oft 12.Of 68.0 0.0 68.0 13 35 2391 Btuh
Window Total 1 313 (sqft) 6698 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
1 Frame-Wood-Ext 0.08 19.0/0.0 130.0 1.6 205 Btuh
2 Frame-Wood-Ext 0.08 19.0/0.0 59.6 1.6 94 Btuh
3 Frame-Wood-Ext 0.08 19.0/0.0 131.0 1.6 207 Btuh
4 Frame-Wood-Ext 0.08 19.0/0.0 595.9 1.6 939 Btuh
5 Frame-Wood-Ext 0.08 19.0/0.0 360.7 1.6 569 Btuh
6 Frame-Wood-Ext 0.08 19.010.0 736.0 1.6 1160 Btuh
Wall Total 2013 (sqft) 3173 Btuh
Doors Type Area (sqft) HTM Load
1 Insulated-Exterior 24.0 13.3 320 Btuh
2 Insulated-Exterior 17.8 13.3 1 237 Btuh
Door Total 42 (sqft) 557 Btuh
Floors Type R-Value Size HTNI Load
1 Slab On Grade 0.0 1604(ft-perimeter) 0.0 0 Btuh
Floor Total 1604.0 (sqft) 0 Btuh
Zone Envelope Subtotal: 10429 Btuh
Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load
Natural 0.45 19248 0.54 148.0 2928 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 1 X 230 + 1200 1430 Btuh
Sensible Envelope Load: 14787 Btuh
DUCt IOad Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh
Sensible Zone Load 14787 Btuh
EnergyGauge®/USRRZB 0.1 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
Component Loads for Room#2: 2nd Floor
Type* Overhang Window Area(sqft) HTM Load
Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded
10 2 NFRC 0.30,0.35 No No N 8.Oft 2.Oft 20.0 0.0 20.0 13 13 251 Btuh
11 2 NFRC 0.30,0.35 No No N 8.0ft 2.0ft 15.1 0.0 15.1 13 13 190 Btuh
12 2 NFRC 0.30,0.35 No No N 2.0ft 2.0ft 30.2 0.0 30.2 13 13 380 Btuh
13 2 NFRC 0.30,0.35 No No E 2.0ft 2.0ft 45.3 0.0 45.3 13 35 1594 Btuh
14 2 NFRC 0.30,0.35 No No E 2.0ft 2.Oft 16.0 0.0 16.0 13 35 562 Btuh
15 2 NFRC 0.30,0.35 No No E 2.0ft 2.Oft 8.0 0.0 8.0 13 35 281 Btuh
16 2 NFRC 0.30,0.35 No No S 2.0ft 8.0ft 45.3 20.7 24.7 13 15 635 Btuh
17 2 NFRC 0.30,0.35 No No S 2.0ft 5.0ft 21.0 21.0 0.0 13 15 264 Btuh
18 2 NFRC 0.30,0.35 No No W 2.0ft 4.0ft 8.0 0.0 8.0 13 35 282 Btuh
19 2 NFRC 0.30,0.35 No No W 2.0ft 4.0ft 60.4 0.0 60.4 13 35 2125 Btuh
20 2 NFRC 0.30,0.35 No No W 21.Of 2.Oft 10.0 10.0 0.0 13 35 126 Btuh
Window Total 279 (sqft) 6690 Btuh
Walls Type U-Value R-Value Area(sqft) HTM Load
Cav/Sheath
7 Frame-Wood-Ext 0.08 19.0/0.0 134.6 1.6 212 Btuh
8 Frame-Wood-Ext 0.08 19.0/0.0 107.8 1.6 170 Btuh
9 Frame-Wood-Ext 0.08 19.0/0.0 565.2 1.6 891 Btuh
10 Frame-Wood-Ext 0.08 19.0/0.0 260.7 1.6 411 Btuh
11 Frame-Wood-Ext 0.08 19.0/0.0 588.5 1.6 928 Btuh
12 Frame-Wood-Ext 0.08 19.0/0.0 52.0 1.6 82 Btuh
Wall Total 1709(sqft) 2694 Btuh
Doors Type Area (sqft) HTM Load
3 Insulated-Exterior 20.0 13.3 267 Btuh
4 Insulated-Exterior 10.0 13.3 133 Btuh
Door Total 30 (sqft) 400 Btuh
Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load
1 Unvented Attic/Light/Shingle 0.048 1.0/19.0 1919.0 1.15 2204 Btuh
Ceiling Total 1919(sqft) 2204 Btuh
Floors Type R-Value Size HTM Load
2 Interior 0.0 1604(sqft) 0.0 0 Btuh
3 Raised-Open 19.0 315(sqft) 0.7 205 Btuh
Floor Total 1919.-O (sgft) 205 Btuh
Zone Envelope Subtotal: 12193 Btuh
Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load
Natural 0.45 17271 0.46 125.6 2485 Btuh
Internal Occupants Btuh/occupant Appliance Load
gain 5 X 230 + 0 1150 Btuh
Sensible Envelope Load: 15828 Btuh
Duct load Average sealed,Supply(R6.0-Cond.),Retum(R6.0-Cond.) (DGM of 0.000) 0 Btuh
Sensible Zone Load 15828 Btuh
EnergyGauge®/USRRZB 0.1 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
The following window Excursion will be assigned to the system loads.
Windows October excursion for System 1 1116 Btuh
July excursion for System 2 0 Btuh
Excursion Subtotal: 1116 Btuh
Duct load 0 Btuh
Sensible Excursion Load 1116 Btuh
EnergyGauge®/USRRZB v3.1 Page 3
Manual J Summer Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
SYSTEM GROUPS(BLOCK LOADS)
Sensible Envelope Load 14787 Btuh
Window Excursion 1116 Btuh
Cooling Loads Sensible Duct Load (duct gain multiplier of 0.000) 0 Btuh
(Includes 0 Btuh due to window excursion)
Sensible ventilation 0 Btuh
For System(s): Zone Sensible gain 15903 Btuh
1 Latent infiltration/ventilation gain 5329 Btuh
Serving Zones: Latent duct gain 0 Btuh
1 Latent occupant gain 200 Btuh
Latent other gain 0 Btuh
Total block load 21432 Btuh
Sensible Envelope Load 15828 Btuh
Window Excursion 0 Btuh
Cooling Loads Sensible Duct Load (duct gain multiplier of 0.000) 0 Btuh
Sensible ventilation 0 Btuh
For System(s): Zone Sensible gain 15828 Btuh
2 Latent infiltration/ventilation gain 4523 Btuh
Serving Zones: Latent duct gain 0 Btuh
2 Latent occupant gain 1000 Btuh
Latent other gain 0 Btuh
Total block load 21351 Btuh
EnergyGauge®/USRRZB 0.1 Page 4
Manual J Summer Calculations
Residential Load - Component Details (continued)
Elite Homes Inc. Project Title: Climate:FL_JACKSONVILLE_INTL_ARPT
Lot 27 5th Street
Atlantic Beach, FL 32233-0000
6/3/2013
WHOLE HOUSE TOTALS
Sensible Envelope Load All Zones 31731 Btuh
Sensible Duct Load 0 Btuh
Total Sensible Zone Loads 31731 Btuh
Sensible ventilation 0 Btuh
Blower 0 Btuh
Whole House Total sensible gain 31731 Btuh
Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 9852 Btuh
Latent ventilation gain 0 Btuh
Latent duct gain 0 Btuh
Latent occupant gain (6.0 people @ 200 Btuh per person) 1200 Btuh
Latent other gain 0 Btuh
Latent total gain 11052 Btuh
TOTAL GAIN 42783 Btuh
EQUIPMENT
1. Central Unit # 24000 Btuh
2. Central Unit # 24000 Btuh
*Key: Window types(Panes-Number and type of panes of glass)
(SHGC-Shading coefficient of glass as SHGC numerical value)
(U-Window U-Factor)
(InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roller Shades(R))
- For Blinds:Assume medium color,half closed
For Draperies:Assume medium weave,half closed
For Roller shades:Assume translucent,half closed
(IS-Insect screen:none(N), Full(F)or Half(%)) 10
(Ornt-compass orientation)
Version 8
EnergyGauge®/USRRZB v3.1 Page 5
L�[LF1 . E COI
FORM 405-10 -
�.&JL
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDI
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 27 5th Street Builder Name: Elite Homes Inc.
Street: Permit Office: Atlantic Beach
City,State,Zip: Atlantic Beach, FL,32233-0000 Permit Number:
Owner: Elite Homes Inc. Jurisdiction: 261100
Design Location: FL,Jacksonville
1. New construction or existing New(From Plans) 9. Wall Types(4386.3 sqft.) Insulation Area
a.Frame-Wood, Exterior R=19.0 4386.30 ft2
2. Single family or multiple family Single-family
b.N/A R= ft2
3. Number of units,if multiple family 1 c. N/A R- ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types (1919.0 sqft.) Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1919.00 ft2
6. Conditioned floor area above grade(ft2) 3523 b.N/A R= ft2
c.N/A R= ft2
Conditioned floor area below grade(ft2) 0 11.Ducts R ft2
7. Windows(592.5 sgft.) Description Area a.Sup: 1st Floor,Ret:1st Floor,AH:2nd Floor 6 352.3
a. U-Factor: Dbl, U=0.35 592.53 ft2 b.Sup: 2nd Floor, Ret:2nd Floor,AH:2nd Floor 6 352.3
SHGC: SHGC=0.30
b. U-Factor: NIA ft2 12.Cooling systems kBtu/hr Efficiency
a.Central Unit 24.0 SEER:13.00
SHGC: b.Central Unit 24.0 SEER:13.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:7.70
SHGC: b. Electric Heat Pump 24.0 HSPF:7.70
Area Weighted Average Overhang Depth: 4.925 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
a.Propane Tankless Cap: 1 gallons
8. Floor Types (3523.0 sqft.) Insulation Area EF:0.840
a.Slab-On-Grade Edge Insulation R=0.0 1604.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1604.00 ftz None
c.other(see details) R= 315.00 ft2 15.Credits None
Glass/Floor Area: 0.168 Total Proposed Modified Loads: 46.85 PASS
Total Standard Reference Loads: 77.21
1 hereby certify that the plans and specifications covered by Review of the plans and 0�.111E 5rA3.
this calculation are in compliance with the Florida Energy specifications covered by this .y Oma,
Dgitaiy signed by Timothy D.Gardner calculation indicates compliancevj n„
Code. Timothy D. ON:CN=TimWhy D.Gardner,C= _==
US,O=USA HERS with the Florida Energy Code. F' f„+it '"� `` "'-•'"�' t
Reason:I attest to the accuracy and - -t- ::,•.p •'•"...
d
���+T'o
PREPARED BY: rin ll - rdegdt"d1hOfi.03cuisdomen1 Before construction is complete -
maDate:2013. 1448:30
DATE: _ _ this building will be inspected for O a
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
wt
with the Florida Energy Code. COO
OWNER/AGENT: _ _ BUILDING OFFICIAL:
DATE: DATE:
Compliance requires an envelope leakage test report, by a Florida Class 1 Rater, in accordance with Table B-1.1.2.
6/3/2013 1:07 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6
PROJECT
Title: Lot 27 5th Street Bedrooms: 5 Address Type: Lot Information
Building Type: User Conditioned Area: 3523 Lot# 27
Owner: Elite Homes Inc. Total Stories: 2 Block/SubDivision: 5th Street
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Elite Homes Inc. Rotate Angle: 0 Street:
Permit Office: Atlantic Beach Cross Ventilation: County: Duval
Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach ,
Family Type: Single-family FL, 32233-0000
New/Existing: New(From Plans)
Comment:
CLIMATE
V// IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Block1 1604 19248
2 Block2 1919 17271
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1 st Floor 1604 19248 Yes 1 1 1 Yes Yes Yes
2 2nd Floor 1919 17271 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 193.5 ft 0 1604 ft2 ---- 0.6 0.2 0.2
2 Floor Over Other Space 2nd Floor ---- ---- 1604 ftz 0 0 0.5 0.5
3 Raised Floor 2nd Floor ---- ---- 315 ftz 19 0 0.5 0.5
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2400 ftz 0 ftz Medium 0.85 No 0.9 No 19 36.9
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Unvented 0 1919 ftz N N
6/3/2013 1:07 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Unvented) 2nd Floor 1 1919 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
y Ornt To Wall TypeFt In Ft o
_ 1 N Exterior Frame-Wood 1st Floor 19 13 8 12 164.0 ft2 0.23 0.5 0
_ 2 N Exterior Frame-Wood 1st Floor 19 7 5 12 89.0 ft2 0.23 0.5 0
_ 3 N Exterior Frame-Wood 1st Floor 19 13 9 12 165.0 ft2 0.23 0.5 0
_4 E Exterior Frame-Wood 1st Floor 19 55 8 12 668.0 ft2 0.23 0.5 0
_ 5 S Exterior Frame-Wood 1st Floor 19 39 10 12 478.0 ft2 0.23 0.5 0
_ 6 W Exterior Frame-Wood 1st Floor 19 67 12 804.0 ft2 0.23 0.5 0
7 N Exterior Frame-Wood 2nd Floor 19 21 1 9 189.8 ft2 0.23 0.5 0
_ 8 N Exterior Frame-Wood 2nd Floor 19 15 4 9 138.0 ft2 0.23 0.5 0
9 E Exterior Frame-Wood 2nd Floor 19 70 6 9 634.5 ft2 0.23 0.5 0
_10 S Exterior Frame-Wood 2nd Floor 19 36 4 9 327.0 ft2 0.23 0.5 0
_11 W Exterior Frame-Wood 2nd Floor 19 73 9 657.0 ft2 0.23 0.5 0
12 W Exterior Frame-Wood 2nd Floor 19 8 9 72.0 ft2 0.23 0.5 0
DOORS
# Ornt Door Type Space Storms U-Value Ft In
In FtWidthArea
1 N Insulated 1st Floor None .46 3 8 24 ft2
2 E Insulated 1st Floor None .46 2 8 6 8 17.8 ft2
3 N Insulated 2nd Floor None .46 3 6 8 20 ft2
4 W Insulated 2nd Floor None .46 1 6 6 8 10 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Low-E Double Yes 0.35 0.3 34.0 ft2 8 ft 0 in 1 ft 0 in None None
2 N 2 Vinyl Low-E Double Yes 0.35 0.3 5.4 ft2 10 ft 0 in 2 ft 6 in None None
3 N 3 Vinyl Low-E Double Yes 0.35 0.3 34.0 ft2 2 ft 0 in 5 ft 0 in None None
4 E 4 Vinyl Low-E Double Yes 0.35 0.3 17.0 ft2 2 ft 0 in 12 ft 0 in None None
5 E 4 Vinyl Low-E Double Yes 0.35 0.3 16.0 ft2 2 ft 0 in 3 ft 0 in None None
6 E 4 Vinyl Low-E Double Yes 0.35 0.3 21.3 ft2 2 ft 0 in 12 ft 0 in None None
7 S 5 Vinyl Low-E Double Yes 0.35 0.3 21.3 ft2 11 ft3 in 2 ft0 in None None
8 S 5 Vinyl Low-E Double Yes 0.35 0.3 96.0 ft2 11 ft 3 in 2 ft 0 in None None
9 W 6 Vinyl Low-E Double Yes 0.35 0.3 68.0 ft2 2 ft 0 in 12 ft 0 in None None
10 N 7 Vinyl Low-E Double Yes 0.35 0.3 20.0 ft2 8 ft 0 in 2 ft 0 in None None
11 N 7 Vinyl Low-E Double Yes 0.35 0.3 15.1 ft2 8 ft 0 in 2 ft 0 in None None
12 N 8 Vinyl Low-E Double Yes 0.35 0.3 30.2 ft2 2 ft 0 in 2 ft 0 in None None
13 E 9 Vinyl Low-E Double Yes 0.35 0.3 45.3 ft2 2 ft 0 in 2 ft 0 in None None
14 E 9 Vinyl Low-E Double Yes 0.35 0.3 16.0 ft2 2 ft 0 in 2 ft 0 in None None
15 E 9 Vinyl Low-E Double Yes 0.35 0.3 8.0 ft2 2 ft 0 in 2 ft 0 in None None
6/3/2013 1:07 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
16 S 10 Vinyl Low-E Double Yes 0.35 0.3 45.3 ft2 2 ft 0 in 8 ft 0 in None None
17 S 10 Vinyl Low-E Double Yes 0.35 0.3 21.0 ft2 2 ft 0 in 5 ft 0 in None None
18 W 11 Vinyl Low-E Double Yes 0.35 0.3 8.0 ft2 2 ft 0 in 4 ft 0 in None None
19 W 11 Vinyl Low-E Double Yes 0.35 0.3 60.4 ft2 2 ft 0 in 4 ft 0 in None None
20 W 12 Vinyl Low-E Double Yes 0.35 0.3 10.0 ft2 21 ft 0 in 2 ft 0 in None None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000395 3651.9 200.48 377.04 .3746 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:7.7 24 kBtu/hr 1 sys#1
2 Electric Heat Pump None HSPF:7.7 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block, Ducts
1 Central Unit Split SEER:13 24 kBtu/hr 720 cfm 0.7 1 sys#1
2 Central Unit Split SEER: 13 24 kBtu/hr 720 cfm 0.75 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation-
1 Propane Tankless Exterior 0.84 1 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF —
None None ft2
DUCTS
/ --Supply--- ---Return--- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 1st Floor 6 352.3 ft 1st Floor 88.075 Default Leakage 2nd Floor (Default) (Default) 1 1
2 2nd Floor 6 352.3 ft 2nd Floor 88.075 Default Leakage 2nd Floor (Default) (Default) 2 2
6/3/2013 1:07 PM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6
TEMPERATURES
Programable Thermostat:None Ceiling Fans:
Jan F M Apr
jMa
a May
Aug
Jun
Heating Dec
Jan Feb Mar �X�Apr € May
rj
Jun lX�Jul lX�Aug lX�Sep Oct �X�Nov �Oct NovX�Dec
Venting
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 68 68
6/3/2013 1:07 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10 Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: PERMIT#:
Atlantic Beach, FL, 32233-0000
MANDATORY REQUIREMENTS SUMMARY- See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heatingand
controls cooling system. Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load. -
Ducts 403.2.2 All ducts, air handlers,filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)or shutoff(gas). Circulating system pipes insulated to= R-2
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70% of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
6/3/2013 1'07 PM 9Y 9
Ener Gau e®USA-FlaRes2010 Section 405.4.1 compliant Software Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 61
The lower the EnergyPerformance Index,the more efficient the home.
Atlantic Beach, FL, 32233-0000
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
a.Frame-Wood, Exterior R=19.0 4386.30 ft2
2. Single family or multiple family Single-family b.N/A R= ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
5 d.N/A R= ftz
4. Number of Bedrooms 10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 1919.00 ftz
6. Conditioned floor area(ftz) 3523 b.N/A R= ftZ
c.N/A R= ftz
7. Windows" Description Area 11.Ducts R ftz
a. U-Factor: Dbl, U=0.35 592.53 ftz a.Sup:1st Floor,Ret:1st Floor,AH:2nd Floor 6 352.3
SHGC: SHGC=0.30 b.Sup: 2nd Floor, Ret:2nd Floor,AH:2nd Floor 6 352.3
b. U-Factor: N/A ftz
SHGC: 12.Cooling systems kBtu/hr Efficiency
ftz a.Central Unit 24.0 SEER:13.00
c. U-Factor: N/A b.Central Unit 24.0 SEER:13.00
SHGC:
d. U-Factor: N/A ftz kBtu/hr Efficiency
13. Heating systems y
SHGC: a.Electric Heat Pump 24.0 HSPF:7.70
Area Weighted Average Overhang Depth: 4.925 ft. b.Electric Heat Pump 24.0 HSPF:7.70
Area Weighted Average SHGC: 0.300
Insulation Area 14.Hot water systems Cap: 1 gallons
8. Floor Types z a.Propane
a.Slab-On-Grade Edge Insulation R=0.0 1604.00 ft EF:0.84
b.Floor Over Other Space R=0.0 1604.00 ftz b. Conservation features
c.other(see details) R= 315.00 ftz None
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for BuildingO�TKE ST,gl�
Construction through the above energy saving features which will be installed (or exceeded) _- p
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: _ Date: Q
p
Address of New Home: City/FL Zip: C00 W'>EE
-- - W
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Lot 27 5th Street Builder Name: Elite Homes Inc.
Street: Permit Office: Atlantic Beach
City,State,Zip: Atlantic Beach, FL,32233-0000 Permit Number:
Owner: Elite Homes Inc. Jurisdiction: 261100
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material.
Air-permeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access (except unvented attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/doorjambs and framing is sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subfloor decking.
floors) Air barrier is installed at any exposed edge of insulation.
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit,or narrow cavities are filled by
sprayed/blown insulation.
Garage separation Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation
extends behind piping and wiring.
Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
separating them from the exterior wall.
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wall between dwelling units.
HVAC register boots HVAC register boots that penetrate building envelope are sealed to
subfloor or drywall.
Fireplace I Fireplace walls include an air barrier.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
J ;r ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002832 Date 7/02/13
Property Address . . . . . . 360 5TH ST
Application type description SINGLE FAMILY RESIDENCE
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 400000
--------------------------------------------------------
Application desc
NEW HOME
-----------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
AF AB VENTURE LLC ELITE HOMES INC.
357 12TH ST 357 12TH ST
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 349-2803
--- Structure Information 000 000 NEW HOME
Construction Type . . . . . TYPE 5-B
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
--------------------------------------------------
Permit . . . . . . PLUMBING PERMIT
Additional desc . .
Sub Contractor . . NELSON PLUMBING CO. INC.
Permit Fee . . . . 258 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/29/13
----------------------------------------------
Special Notes and Comments
Avoid damage to underground water/sewer utilities . Verify
vertical and horizontal location of utilities . Hand dig if
necessary. If field coordination is needed, call 247-5834 .
Ensure all meter boxes, sewer cleanouts and valve covers
are set to grade and visible.
A sewer cleanout must be installed at the property line.
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
A reduced pressure zone backflow preventer must be
installed if irrigation will be provided or if there is a
private well on the property. Backflow preventer must be
tested by a certified tester and a copy of the results sent
to Public Utilities .
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
All concrete driveway aprons must be 5" thick, 4000 psi,
with fibermesh from the edge of pavement to ,t,�h�,ee property
PERMIT IS�PM.VED 16RIjinI 4�Nrp44V'IPRL� FINfiANYW'BER(4� D'tPYAN�R A�'PI"OI'HE FLORIDA
BUILDING CODES.
J
111
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
j ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Page 2
Application Number . . . . . 13-00002832 Date 7/02/13
-----------------------------------------------------------------------
Special Notes and Comments
right-of-way.
Full right-of-way restoration, including sod, is required.
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O.
A sewer cleanout must be installed at the property line .
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
*SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST
CONTROL COMPANY PRIOR TO C.O.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
-----------------------------------------------------------
Other Fees . . . . . . . . . STATE PLBG DCA SURCHARGE 3 . 87
STATE PLBG DBPR SURCHARGE 3 . 87
--------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 258 . 00 258 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 7 . 74 7 . 74 . 00 . 00
Grand Total 265 . 74 265 . 74 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
PLUMBING PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-58826 Fax(904) 247-5845 I
d r� PERMTr# 13 r
JOB ADDRESS: �� LC/+ ' `
NEW OR REPLACEMENT INSTALLATION: Project Value s
TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY
Bathtub Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
g SlopSink
FFountain Floor Thre Compartment Sink
Floor Sink Toilet -�--
Hose Bibs _ Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory Water Heater
Other Fixtures _ Water Treating System
RE-PIPE;
TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY
Bathtub Septic Tank&Pit
Clothes Washer Shower
Dishwasher Shower Pan
Drinking Fountain Slop Sink
Floor Drain Three Compartment Sink
Floor Sink Toilet
Hose Bibs Urinal
Kitchen Sink Vacuum Breakers
Laundry Tray Water Connected Appliances
Lavatory Water Heater
Other Fixtures Water Treating System
MISCELLANEOUS:
❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans-
❑ Lawn Sprinkler System-Number of Heads ❑ Well **
** SJRWD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.*'
❑ Other
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have Pea
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Phone Number
Plumbing Company 2�SGn_P) M bl t`�-si Co `1 V)C Office Phone �6�_ � 6 0 Fax X- �13
Co. Address: l 1 a`A - l Tai F C' O\, State_n Zip 3
License Holder(P22-��
rint : __ ( �T1 N) t'�S to ertification/Registration# C R U� `w , l
t .SignaturY�LNAs�.Jjf aH der
:Sroti °�s Notary Publi -State o on a 20
= •__My Comm.Expires Nov 16,zols worn and subscri ed before me s day of '�—
=,� T, Commission#EE 137475
''-?,�;;;.•° sooaed Through N86081 Nauy Assn. ignature of Notary Public '
It CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
J ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002832 Date 8/23/13
Property Address . . . . . . 360 5TH ST
Application type description SINGLE FAMILY RESIDENCE
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 400000
----------------------------------------------------------------------------
Application desc
NEW HOME
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
AF AB VENTURE LLC ELITE HOMES INC.
357 12TH ST 357 12TH ST
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 349-2803
--- Structure Information 000 000 NEW HOME
Construction Type . . . . . TYPE 5-B
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Sub Contractor . . HWK MECHANICAL INC (BEEHIVE)
Permit Fee . . . . 143 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/19/14
----------------------------------------------------------------------------
Special Notes and Comments
Avoid damage to underground water/sewer utilities . Verify
vertical and horizontal location of utilities . Hand dig if
necessary. If field coordination is needed, call 247-5834 .
Ensure all meter boxes, sewer cleanouts and valve covers
are set to grade and visible .
A sewer cleanout must be installed at the property line.
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible .
A reduced pressure zone backflow preventer must be
installed if irrigation will be provided or if there is a
private well on the property. Backflow preventer must be
tested by a certified tester and a copy of the results sent
to Public Utilities .
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
All concrete driveway aprons must be 5" thick, 4000 psi,
with fibermesh from the edge o}}f..�� pavemenntt to
ll ptthe�e property
PERMIT IS Ai TD OA%i41qfA@r gCIrR& ARE C%%S4 R q IC_SE'A 'CJRDINA L AN�4& FLORIDA
BUILDING CODES.
IS CITY OF ATLANTIC BEACH
s 800 SEMINOLE ROAD
J ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
J3il��
Page 2
Application Number . . . . . 13-00002832 Date 8/23/13
------------------------------------------------------
Special Notes and Comments
right-of-way.
Full right-of-way restoration, including sod, is required.
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O.
A sewer cleanout must be installed at the property line.
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible .
*SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST
CONTROL COMPANY PRIOR TO C.O.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
-----------------------------
Other Fees .
. STATE MECH DCA SURCHARGE 2 . 15
STATE MECH DBPR SURCHARGE 2 . 15
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----- ---------- ----------
Permit Fee Total 143 . 00 143 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 30 4 . 30 . 00 . 00
Grand Total 147 . 30 147 . 30 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
2 Ph(904) 247-5826 Fax (904) 247-5845
.TOB ADDRESS: LJ 60 �rN PERMTr
PROJECT VALUE $
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATIONwL
Air Conditioning: Unit Quantity �?— Tons Per Unit 1_S
Heat: Unit Quantity—sem BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI#
Air Conditioning: Unit Quantity Tons Per Unit REQUIRED
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name COY/�'�-� Z-/;�'? Phone Numbery9
D11.4 Lei- yo4�-Y79- 9oY-P7 t
Mechanical Company4(4k/ylf,Cll 4A1a4& Dvc. m Z g a Office Phone -A 1 Fax Cot 1 Cr
Co. Address: 4132 DZ14TZ L 44 L City eA�UA t-4r-n State f:7— Zip 3 2-O
License Holder(Print): W&S G •U)Z_-1SbtJ St e ification/Registration#
Notarized Signature of License Holder
Sworn and subsc bed before me#Vs `U day(�of ' 20
KRISTINA T.WILSON Signature of Notary Public
Notary Public,State of Florida
My Comm.Expires April 21,2016
Commission No.EE 188868
CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
►� ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002832 Date 8/28/13
Property Address . . . . . . 360 STH ST
Application type description SINGLE FAMILY RESIDENCE
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 400000
----------------------------------------------------------------------------
Application desc
NEW HOME
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
AF AB VENTURE LLC ELITE HOMES INC.
357 12TH ST 357 12TH ST
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 349-2803
--- Structure Information 000 000 NEW HOME
Construction Type . . . . . TYPE 5-B
Occupancy Type . . . . . . RESIDENTIAL
Flood Zone . . . . . . . . ZONE X
----------------------------------------------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc NEW SERVICE
Sub Contractor KNIGHT ELECTRIC LLC
Permit Fee . . . . 125 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/24/14
----------------------------------------------------------------------------
Special Notes and Comments
Avoid damage to underground water/sewer utilities . Verify
vertical and horizontal location of utilities . Hand dig if
necessary. If field coordination is needed, call 247-5834 .
Ensure all meter boxes, sewer cleanouts and valve covers
are set to grade and visible.
A sewer cleanout must be installed at the property line .
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
A reduced pressure zone backflow preventer must be
installed if irrigation will be provided or if there is a
private well on the property. Backflow preventer must be
tested by a certified tester and a copy of the results sent
to Public Utilities .
If on-site storage is required, a post construction
topographic survey documenting proper construction will be
required.
All concrete driveway aprons must be 5" thick, 4000 psi,
with fibermesh from the edge
o}f- pavement to, the
property
_4J&
PERMIT IS�AVED S�L ��1 ►NIF�A�LL"f`YFY OI� tNEI'Oi2DIAN A�VeIHE FLORIDA
BUILDING CODES.
CITY OF ATLANTIC BEAM
800 SEMINOLE RAD
r) ATLANTIC BEACH, FL 32233
J
INSPECTION PHONE LINE 247-5814
Page 2
Application Number . . . . . 13-00002832 Date 8/28/13
----------------------------------------------------------------------------
Special Notes and Comments
right-of-way.
Full right-of-way restoration, including sod, is required.
Full erosion control measures must be installed and
approved prior to beginning any earth disturbing
activities . Contact Public Works (247-5834) for Erosion
and Sediment Control Inspection prior to start of
construction.
2010 FLORIDA BUILDING CODE, 2008 NATIONAL ELECTRIC CODE
*PROVIDE FINAL ELEVATION CERTIFICATE PRIOR TO C.O.
A sewer cleanout must be installed at the property line .
Cleanout must be covered with an RT1 concrete box with
metal lid. Cleanout to be set to grade and visible.
*SUBMIT "CERTIFICATE OF COMPLIANCE" BY A LICENSED PEST
CONTROL COMPANY PRIOR TO C.O.
WINDOW AND DOOR INSPECTION:
*INSTALLATION INSTUCTIONS REQUIRED
*ALL STICKERS ARE TO REMAIN ON THE WINDOWS
*PROVIDE ACCESS TO ALL WINDOWS TO INSPECT FASTENERS
-----------------------------------------------------------------------
Other Fees . . . . . . . . STATE ELEC DCA SURCHARGE 2 . 00
STATE ELEC DBPR SURCHARGE 2 . 00
-------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ---------
Permit Fee Total 125 . 00 125 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 129 . 00 129 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION 42
CITY OF ATLANTIC BEACH
800 Seminole Rd, Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845 p
JOB ADDRESS: J 7 ST/-e-q-- PERMIT
JEA INFORMATION REQUIRED ON ALL PERMITS aD AMPS VOLTS PHASE
VALUE OF WORK$
NEW SERVICE ❑ Overhead ❑ Underground Underground up Pole
❑Residential(Main) Service �
❑0-100 amps ❑101-150amps L151-200amps !_' amps # of Meters
-j Commercial(Main) Service
❑0-100 amps ❑101-150amps ❑151-200amps []_amps ❑CT Service amps
Conductor Type Size
--Multi-Family(Main) Service
❑0-100 amps [110 1-1 50amps ❑151-200amps ❑ amps #of Unit Meters
Temporary Pole ❑ amps
SERVICE UPGRADE ❑ amps ❑ CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
❑100 amps ❑150amps ❑200amps ❑ amps ECT Service amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switches: 0-30amps 31-l 00amps 101-200amps
Appliances: 0-30amps 31-100amps 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS
❑Swimming Pool ❑ Sign ❑Smoke Detectors_Qty ❑Transformers KVA :i Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans)
Qty volts/amps VALUE OF WORK$
REPAIRS/MISCELLANEOUS
❑Replace Burnt/Damaged Meter Can ❑Safety Inspection ❑Panel Change ❑OH to UG
Other:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction.
Property Owners NameI/ Phone Number
Electrical Company TnrrrArr �Z.cnyt,•C__ j Office-�P^ "hone /,�4�?- Fax 2W-M13
Co. Address:
1/k t City _1�1� h. State Zip 32 G
License Holder (Print): p r . 4 r State Certification/Registration# �'P/30(2 S'L3
Notarized Signat
'. SHIRLEY L GRAHAM
,.. c nt4+Mlss�� e is 0 2
fat` 4 2
•` APIRES:February
dundedThruNot IiCUnderwritersA/ 4::��
. Notary Pblic
�S yL�jr
1
CITY OF ATLANTIC BEACH .
j 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003396 Date 9/11/13
Property Address . . . . . . 360 5TH ST
Application type description MECHANICAL GAS PIPING
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1p gas
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
AF AB VENTURE LLC FLORIDA PROPANE PARTNERS
357 12TH ST DBA:GRIFFIS GAS & MACK GAS
ATLANTIC BEACH FL 32233 115 B SOLANO RD
PONTE VEDRA BEACH FL 32082
(904) 543-4343
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL GAS PIPE PERMIT
Additional desc . .
Permit Fee . . . . 90 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/10/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 90 . 00 90 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 94 . 00 94 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: 3 � 0 5-rl^— —� PERMIT# 0000 15P
PROJECT VALUE $ ARI# REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
Manual J documentation required on residential change out
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty 1 Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets T— Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters �_ Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
?ermit becomes void if work does At commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
iot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Phone Number
Mechanical Company F7 I a_:P - 88
Tfimm_�Office Phone ax
�o. Address: City State Zip
3D_Z_a '
License Holder(Print): �a. O State Certification/Registration#
Votarized Signature of License Holder
Before me this day of 20
Signature of Notary Public
C, CITY OF ATLANTIC BEACH
i 800 SEMINOLE ROAD
-r ATLANTIC BEACH, FL 32233
J INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003348 Date 9/04/13
Property Address . . . . . . 360 STH ST
Application type description ELECTRIC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
-------------------------------------------
Application desc
LOW VOLTAGE
-----------------------------------------
Owner Contractor
--------------
------------------------
AF AB VENTURE LLC PROTECTION GROUP USA INC
357 12TH ST 1556 WHITLOCK AVE
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32211
----------------------------------------
Permit . . . . . . ELECTRICAL PERMIT
Additional desc . . . 00
Permit Fee . . . . 90 . 00 Plan Check Fee
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 3/03/14
_ -----------------------------
Other Fees .
STATE ELEC DCA SURCHARGE 2 . 00
STATE ELEC DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged
Paid Credited ----Due---
_ _ ---------- --
--------- ----------
Permit Fee Total 90 . 00 90 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 94 . 00 94 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd, Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: -�lN I�F�J s AI A;U-- f�fT�1� _ PERMIT#
JEA INFORMATION REQUIRED ON ALL PERMITS
AMPS VOLTS PHASE
VALUE OF WORK$ �3 )
NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole
`Residential(Main) Service # of Meters
-0-100 amps -101-150amps ==151-200amps _ amps
-Commercial(Main) Service - ams -CT Service amps
-0-100 amps -101-150amps -151-200amps - P
Conductor Type Size
-Multi-Family(Main) Service - # of Unit Meters
-0-100 amps 101-.101 -151-200amps __amps
-Temporary Pole ❑ amps
SERVICE UPGRADE amps CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
-100amps -150amps -200amps amps -CT Service amps
ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
s
Appliances: 0-30amps
outlets/Switches: 0-30amps 31-100amps P
31-l 00amP s 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS KV A -Motors hp
-Swimming Pool - Sign Smoke Detectors_Qty -Transformers
FIRE ALARM SYSTEM (Requires 3 sets of plans) VALUE OF WORK,S
Qty volts/amps
REpAERS/NIISCELLANEOUS
-Replace Burnt/Damaged Meter Can -Safety Inspection _Panel Change -OH to UG
ig'Other: �-OGU VoL���
Permit becomes void if work does not comb nt a thinnd arect Allsix tp provisions
ons o or of laws and ordwork is inances govemed or i g thisd for 'work willl be complieds. I hereby rtwith whether ify that I e
read this application and know the same to
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance o
construction.
Property Owners Name �1 "rl S S v� Phone Number _
'�Q,o�GT1 o�
Electrical Company G f2Uk
P
ttS 4- Office PhoneFa'FIO`1,-- )- f3
Co. Address: 1 %(c W}�7Tc-�-
City"�++c,>i6So.,�vj U- ._ State Zip 3
License Holder(Print): State Certification/Registration# XZ-Q=zzq
Notarized Signature of License Holder
MIC4IELE M.SPEAKER 13—
Sworn ands scribed before me this �� day of rvfi►� 20
Notary Public-State of Florida
'a My Comm.Expires NOVO,2016 Signature of Notary Public
Commission#EE 843836