Loading...
103 S Saratoga Cir 2013 HVAC ,C,� CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . 13-00002913 Date 6/21/13 Property Address . . . . . . 103 S SARATOGA CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ----------------------------------------------------------------------- Application desc 1 cu 1 ahu -------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- MCIVER, CYRUS D FLORIDA AIR SERVICE & ENG.LLC 103 SARATOGA CIR S 150 ATLANTIC BEACH FL 32233 HIDDEN RD #308 PONTE VEDRA FL 32081 (877) 735-2247 --------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/18/13 ------------------------------------------------------------ Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 -------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 OB ADDRESS: 10,3 SIf4u-yflck C/L—. PERMIT# PROJECT VALUE $ 310 0- 01D ARI# �0 `� �� REQUIRED _Air Handling Equipment Only '-Air Handling Unit & Condenser Condenser Only 1EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity f Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating t 3 Duct Systems: Total CFM REQUIRED P IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) 1. Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators LLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or at. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name d�-EA( Di 9�/ d- Phone Number 4echanical Company rf a��A ��»`cam Office Phone 41W( Fax h S9qj-- 'o. Address: /Sly W!:ba ► City poM UAAA State Pt Zip ,icense Holder(Print): State Certification/Registration# CAe.l e19S 11 i6tarized Signature of License Holder 1 Before me this ` day of >�'' " 9 JMN -1. M PubhSignature of Notary Public V —m fissi Project Summa Job: 103 SARATOGA - wrightsoft Date: 05/2013 Entire House By: cif FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,POINTE VEDRE,FL 32081 Phone:904-823-9696 Email:fae@engineercom Proeect Information For: 103 SARATOGA JACKSONVILLE, FL Notes: Design Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F a Daily range M Relative Tiumidity 50 % r Moisture difference 52 gr/Ib ; Heating Summary Sensible Cooling Equipment Load Sizing Structure 18880 Btuh Structure 16835 Btuh § Ducts 6831 Btuh Ducts 7709 Btuh -- Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh %t'3 Humidification 0 Btuh Blower 0 Btuh - Piping 0 Btuh Equipment load 25711 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24543 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5802 Btuh Ducts 1703 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1500 1500 Equipment latent load 7505 Btuh Volume(ft3) 10138 10138 Air changes/hour 0 0.90 Equipment total load 32049 Btuh Equiv.AVF (cfm) 0 152 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade 3.0 TON Trade 3.0 TON Model 25HBC336 Cond 25HBC336 ARI ref no. 3699488 Coil FB4CNF036 ARI ref no. 3699488 Efficiency 8 HSPF Efficiency 13 SEER Heating input Sensible cooling 23800 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 10200 Btuh Temperature rise 26 °F Total cooling 34000 Btuh - - -- ---AcAual air-flow 1200 cfm Actual air flow 1200 cfm - - Air flow factor 0.047 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.77 Printout certified byACCA to meet all requirements of Manual J 8th Ed. ,t wrightsoft Right-Suite®universal 8.0.06 RSU13554 2013-Jun-21 08:40:03 ACCP. C:\Users\FRONTDESK\Documents\PROJECTS\PROVIDENCE\3.OTON-DESE.rup Calc=MJ8 Housefaces:NE Page