620 Beach Ave HVAC 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
r) ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00002943 Date 6/26/13
Property Address . . . . . . 620 BEACH AVE
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 2 ton
---------------------------------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
FRISCH, MARK & MEREDITH ENVIRONMENTAL A/C SERVICES, INC
620 BEACH AVE 8110 CYPRESS PLAZA DR STE 106
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32256
(904) 279-0030
---------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/23/13
------------------------------------
Other Fees . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
--------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
06/26/2013 07:27 9042790078 ENVIRONMENTALAIRCOND PAGE 01
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax(904)247-5845
JOB ADDRESS: 62f1 BEACHi AVEN-UE.ATLAN-nc B CHF 32233 PERMff
PROJECT T,ALUE$1 91.00 ARI#5297887 REQUIRED
Air HandmgEqnV=rnttry x Air Hander Unit&Condmwx Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit Seer Ratio
Heat: Unit Quantity BTU's Per Unit REQUIRED
Duct Systems: Total CFM ___. ��
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Vons Per Unit 2.0
Heat: Unit Quantity___I_ BTU's Per Unit 22,$00 Seer Rating 15.00 SEER
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION R wires 3 sets of lens
Fire Sprinklear System Quantity ( equires 3 sets of plans)
Fire Standpipe QuantValue (Requires 3 sets of plans)
Underground Fire Main Value ices 3 sale of ens
Fire Hese Cabinets Quantity ��im 3 its of plans)
Coit au=ial Hoods Quantity 3 sets of dans)
Fire Suppression Systems Quantity (Requiresp )
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
(Jas Piping Outlets Boilers BTU's
Etevatcars/E"ators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned foe'six months.4 hereby rectify that 1 have read
this application and know the Sarno to be true and correct. All provisions of laws and ordinances goveming this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Meredith Frisch Phone Number 904-553-0597
Mechanical Company Environmental Air Conditioning Services, Inc. Office Phone 904-279-0030_ )~ax 904-279-0078
Co.Address: 8110 Cypress Plaza Drive City Jacksonville State FL Zip 32256
Liomse Helder(Paint): Howard K. Stalls.Jr. State Certification/Registration# CAC057409
Notarized Signature of License Holder
t�A,11Alp afore me this 26th of
' jp11 �o�a tit gnature of Notary Pub i
>�171
'#I&- vvr19tit60tt- Rlphl-SuitP®Unlversa1201212.1.03RSU17457 ryyr.
1Reavder111W Chonge0ut Menurl MAC,4569 prtooa BIA JlMrup Colo o MJ0 Front DoOr WOG:$Pogo 4
06/26/2013 07:27 9042790078 ENVIRONMENTALAIRCOND PAGE 02
Project Summary
..UA'
Zone 4-3rd,&Ioor
Ener D
9Y Design Systems, Inc,
12132 Weatherwood Estate,Or W,JodaeonYl le,FL 322x3 Phone:804-268-
3670 Fes;804.288-5870 Emelt;�B.16t?l�gi*1p�.�om
■
For. Frisch Residence
620 Beach Avenue Atlantic Beach FL
Notes: Front of house ,faces .East
Weather Jacksonville Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 94 "F
Inside db 74 "F Inside db 74 of
Design TD 42 4F Design TD 20 4F
Daily range M
Relative humidity 50 %
Moisture difference 52 gr/Ib
Heating Summary Sensible Cooling E=quipment Load Sizing
Structure 11939 Btuh Structure 17970 Stuh
Ducts 0 Stuh Ducts 0 Btuh
Central vent(0 cfrn) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 11939 Btuh Use manufacturers data n
Rate/swing multipplier 0.99
Infiltration Equipment sensible load 17862 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-loose
Fireplaces 0 Structure 3708 Btuh
Ducts 0 Stuh
Heating Cooling Central vent(0 cfm) 0 Stuh
Area(ft') 1162 1162 Equipment latent bad 3708 Btuh
Volume (W) 9296 9296
Air changesthour 0.38 0.20 Equipment total load 21570 Btuh
Equiv,AVF (cfm) 59 31 Req,total capacity at 0.75 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Trane Make Trane
Trade XR15 WEATHERTRON Trade XR15 WEATHERTRON
Model 4TWR5024G1 Cond 4TWR502401
AHRI ref 5020724 Coil "AM7AOA24H21
AHRI ref 5020724
Efficiency 9 HSPF Efficiency 13.0 EER, 15.5 SEER
Heating Input Sensible cooling 16758 Btuh
Heating output 21600 Btuh @ 47'F Latent cooling 7182 Btuh
Temperature rise 25 °F Total cooling 23940 Btuh
cfm
Actual air flow 787 cfm Actual air flow 787 cfm
Air flow factor 0.066 cfm/Btuh Air flow factor 0.044 n H2O
tuh
Static pressure 0 in H2O Static pressure 0 in H2
Space thermostat Load sensible heat ratio 0.83
Calculations approved by RCCA to meet all requirements of Manual J 8th Ed.
wrightsafV Right.Suited9 Unimnel 2012 12,1,03 RSU17d57 Page 4
09M .,1Re64ent4J Changeout Manual,AEAC,4500 Ortega Blvd.Jaax,rup Calc=MJt7 Front Door laaces;SPage 4