Loading...
1879 Beach Ave 2013 HVAC CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD x ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Jit )r� Application Number . . . . . 13-00002959 Date 6/27/13 Property Address . . . . . . 1879 BEACH AVE Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 . 5 TON, 18K BTU ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- PETRONI GERARD P & REIDUNN TRS TROPIC HEATING & AIR 1879 BEACH AVE 750 MAYPORT RD ATLANTIC BEACH FL 322335938 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 83 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/24/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 83 . 00 83 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 87 . 00 87 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: /IY7q 411—11kK PERMIT# PROJECT VALUE $ --�73eV NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer RatingREQUIREDDuct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSATR ALLATIO�N� Air Conditioning: Unit Quantity / Tons Per Unit / • S REQ RED 3- 0 Heat: Unit Quantity / BTU's Per Unit t� /sr«i Seer Rating;�QUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name -K AA p4 4-1VI% Phone Number Mechanical Company Tropic Htg and A/C Office Phone 241-1788 Fax 241-2172 Co. Address: 750 Mayport Road City Ad. Bch State FL Zip 32233_ License Holder(Print): Charlie Marks state certification/Registration# CAC052431 Notarized Signature of License Holder W orn and subscribed efore me t is �O day f _20� AM 0~ i awy vubk,ow d 11 a nature of Notary Public • My C",Eno*M 1t.f1/ Conigiai i EE 01i1>N Certificate of Product Ratings AHRI Certified Reference Number: 5939921 Date: 6/27/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213CN(A,W)018*0**A Indoor Unit Model Number: F134CNF018 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 17400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 16700 Region IV HSPF Rating (Heating). 7.70 Heating Capacity(Btuh) @ 17 F. 9400 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS.which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibi ity r, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at vAow.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectoryorg, Air-Conditioning,Heating, dick on"Verity Certificate"link and enter the AHRI Certified Reference Number and the date on S �. 00 ' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130168096223909665 Job: Petroni Project Summary Date: 6/26/2013 EMEntire House By: Tropic Heating&Air C... NK"beaftTropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 Proiect Information For: Reidunn Petroni, Tropic Heating&AirConditioning,lnc. 1879 Beach Ave,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Desiqn Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 'F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 9766 Btuh Structure 8578 Btuh Ducts 1740 Btuh Ducts 1860 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11507 Btuh Use manufacturer's data 1.00y Rate/swing multiplier Infiltration Equipment sensible load 10439 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1576 Btuh Fireplaces 0 Structure Ducts 309 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ftZ) 600 600 Equipment latent load 1885 Btuh Volume(ft3) 4800 4800 Air changes/hour 0.79 0.41 Equipment total load 123 . Equiv.AVF (cfm) 63 33 Req. total capacity at 0.70 SHR 1.2on 2 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref 0 SEER Efficiency n/a Efficiency 0 Btuh Heating Input 0 MBtuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 479 cfm Actual air flow 479 cfm Actual air flow 0.046 cfm/Btuh Air flow factor 0.042 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jun-26 19:04:32 r= wriSlihitSOft Right-Suite®universal 2012 12.1.07 Right J®Mobile Pagel 'K ..\wstmp\bacc1778-11944821-b3ad-35610a97b5b6.rup Calc=MJ8 Front Door faces: W Petro Job: iRi ht J@ Mobile Report Date: 6/26/20 13am Entire House By: Tropic Heating&Air C... 11111a"ago" Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC-052431 Project • • For: Reidunn Petroni, Tropic Heating&AirConditioning,lnc. 1879 Beach Ave, Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified Wetbulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/fF Btuh %of load Walls 3.4 2378 20.7 Dul. Glazing 19.7 1183 10.3 VAIs Doors 13.5 425 3.7 Ceilings 1.5 893 7.8 Floors 4.1 2486 21.6 Qa&B __Irfiltra5m Infiltration 3.0 2402 20.9 Ducts 1740 15.1 Dors Piping 0 0 Humidification 0 0 Calirgs Ventilation 0 0 A0Q5 Adjustments 0 Total 11507 100.0 Component Btuh/ftz Btuh %of load Walls 1.5 1065 10.2 V\/AIs Glazing 28.1 1689 16.2 Doors 11.4 360 3.4 Intend Gains Ceilings 1.4 846 8.1 dating, Floors 2.0 1171 11.2 Infiltration 0.7 587 5.6 Ducts 1860 17.8 Doors-- Ventilation 0 0 Internal gains 2860 27.4 Ceilings Blower 0 0 40 Ducts Adjustments 0 Floors Infiltration Total 10439 100.0 Latent Cooling Load= 1885 Btuh Overall U-value=0.181 Btuh/ftz-°F Data entries checked. 2013-Jun-26 19:04:32 WrilghXSOft Right-Suite®universal 2012 12.1.07 Right J®Mobile Page 1 AC ...\wstmp\baccl778-11944821-b3ad-35610a97b5b6.rup Calc=MJ8 Front Door faces: W Right-J@ Worksheet Job: Petroni g Date: 013 am Tropp Entire House By: Tropic Heating&Air Condi... Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CACO52431 Entire House Second Floor 1 Room name 100.0 ft 100.0 ft 2 Exposed wall 8.0 ft d 8.0 ft heat/cool 3 Room height 30.0 x 20.0 ft 4 Room dimensions 600.0 ft2 600.0 ft2 5 Room area Ty Construction U-value Lk4�k Area (fe) Load Area (ftp) Load number (Btuh/ft'-°F) or perimeter (ft) (Btuh) or perimeter (ft) I (Btuh) Gross N/P/S Heat Coal Gross N/P/S Heat 11 Cool 6 12B-Ob w 0.097 n 3.36 1.50 240 222 744 333 240 222 744 333 VL__ 1 D-c2ov 0.570 n 19.72 15.37 18 0 362 282 18 0 362 282 128-Obw 0.097 e 3.36 1.50 160 148 498 223 160 148 498 223 0.570 e 19.72 45.54 12 0 230 531 12 0 230 531 1 D-c2ov 11 12B-Obw 0.097 s 3.36 1.50 240 190 638 286 240 190 638 286 �.—D 1 D c2ov 0.570 s 19.72 18.79 18 0 362 345 18 0 362 345 11 DO 0.390 s 13.49 11.43 32 32 425 360 32 32 425 360 126-Obw 0.097 w 3.36 1.50 160 148 498 223 160 148 t-1498 223 1 D-c2ov 0.570 w 19.72 45.54 12 0 230 531 12 0 230 531 C 17A-20xd 0.043 1.49 1.41 600 600 893 846 600 600 893 846 F 19A-Obsto 0.368 - 4.14 1.95 600 600 2486 1171 600 600 2486 1 171 0 0 6 c)AED excursion 7365 5131 7365 5131 Envelope loss/gain 2 2402 587 402 587 12 a) Infiltration 0 0 0 0 b) Room ventilation F21 460 2 460 13 Internal gains: Occupants @ 2302400 2400 Appliances/other 9766 8578 97661 8578 Subtotal(lines 6 to 13) 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 9766 8578 9766 8578 14 Subtotal 18% 22% 1740 1860 18% 22% 1740 1860 15 Duct loads 1 1 1 1 1 115071 104391 1 1 11507 10439 Total room load 479 479 479 479 Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jun-26 19:04:32 Wrighta Clft Right-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1 " ; -*" ...\wstmp\bacc1778-11944821-b3ad-35610a97b5b6.rup Calc=MJ8 Front Door faces: W Com onent Constructions Job: 6/26/2 i t p Date: 6/26/2013 WWI Entire House By: Tropic Heating&Air C... Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 Project • • For: Reidunn Petroni, Tropic Heating&AirConditioning,lnc. 1879 Beach Ave,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Daily range(°F) - 17 ( M ) Method Simplified VVet bulb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BtLW112-01' W-"FBtuh etuh/R' Btuh Btuhjt' Btuh Walls 12B-Obw: Frm wall,brk 4"ext, r-11 cav ins, 1/2'gypsum board int n 222 0.097 11.0 3.36 744 1.50 333 fnsh,2N4"wood frm e 148 0.097 11.0 3.36 498 1.50 223 s 190 0.097 11.0 3.36 638 1.50 286 W 148 0.097 11.0 3.36 498 1.50 223 all 709 0.097 11.0 3.36 2378 1.50 1065 Partitions (none) Windows 1D-c2ov:2 glazing,clr outr,air gas,vnl frm mat,cir innr, 1/4"gap, n 18 0.570 0 19.7 362 15.4 282 1/8"thk;50% blinds 45°,light;50%outdoor insect screen e 12 0.570 0 19.7 230 45.5 531 S 18 0.570 0 19.7 362 18.8 345 w 12 0.570 0 19.7 230 45.5 531 all 60 0.570 0 19.7 1183 28.1 1689 Doors 11 DO:Door,wd so type s 32 0.390 0 13.5 425 11.4 360 Ceilings 17A-20xd:Flat ceiling,tar and gravel roof mat,wd deck, r-20 deck 600 0.043 20.0 1.49 893 1.41 846 ins, 1/2"gypsum board int fish, 1.5"thkns Floors 19A-Obstp: Flr floor,wd fir, 1"thkns,tile fir fnsh,tight bsmt ovr 600 0.368 0 4.14 2486 1.95 1171 2013-Jun-26 19:04:33 Wr'19ht5OfC Right-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1 ...\wstmp\bacc1778-1194-4821-b3ad-35610a97b5b6.rup Calc=MJ8 Front Door faces: W AED Assessment Job: Petroni � Date: 6/26/2013 Enure House By: Tropic Heating&Air C... I I-* Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 Project • • For: Reidunn Petroni, Tropic Heating&AirConditioning,lnc. 1879 Beach Ave,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Wet bulb(°F) - 77 Wind speed (mph) 15.0 7.5 Test for • - • Exposure Hourly Glazing Load 2, 2, 2, 2, � .._.._.. 1, 1, 1, 1, 1, 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly A,erage / AEDlimit Maximum hourly glazing load exceeds average by 19.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Jun-26 19:04:33 Wr ghtsoft Right-Suite®Universal 2012 12.1.07 Right J®Mobile Page 1 ..lwstmplbacc1778-1194-4821-b3ad-3561Da97b5b6.rup Calc=MJ8 Front Door faces: W