2263 N Fairway Villas 2013 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
oil
Application Number . . . . . 13-00002991 Date 7/03/13
Property Address . . . . . . 2263 N FAIRWAY VILLAS LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU 2 TONS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
LANGFORD, ELIZABETH SNYDER HEATING & AIR
PO BOX 2235 P.O. BOX 16826
TALLAHASSEE FL 32316223S JACKSONVILLE FL 32245
(904) 32S-9979
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/30/13
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904)247-5845
OB ADDRESS: Z-:L-US PERmrr#
PROJECTVALUE $ LWO6.2' ARI# '55t?:,u(41 _REQUIRED
—Air Handling Equipment Only ?( Air Handling Unit & Condenser Condenser Only
iEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit _L_
Heat: Unit Quantity BTU'sPerUnit -z.�Acoo Seer Rating I
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
:)t. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Toperty Owners Name N Phone Number 15-11- �PLA LA
4echanical Company Office Phone UW-QkcooFax_�9�17�57-9
.o. Address: City Ite State C-L Zip 1��-Llt,;;
,icense Holder(Print): CLAw*,.e\ /State Certification/Registration# CACI'&IS2609-
i6tarized Signature of License Holder 1A I/
Before 77 day of HOLLY A.FOUST
MT17MISSION#EE 204856
Signature of Notary Pu�lic EXPIRES:July 21,2016
"*.Fle Bonded Thru Budget Notary SerAces
DesignStar Load Calculation
40 Results are intended for use with Rheem heatinq and cooling systems
Information
Street Address 2263 fairway villas In n, Atlantic Beach, FL
32233
Latitude, Longitude 30.33750, -81.7686"
House Square 1028 sq. ft.
Footage:
Name: joy martin
...........
Phone: 123-123-1234
Email: example@maii.com
............... ....................-
House Information
SHR .75
Number of residents 2
Ceiling height 9
Wall U-value R-value 0.091 11
Floor U-value R-value 0.2 15
Ceiling U-value R-value 0.0531 19
Window U-value 0.5
Window SHGF 0.85
Moisture grains 53
...........
Ductloss % 10
Duct gain % 10
.......... ................ .............................. ....................................................................... .............. ................
Cooling infiltraction (ACH) 0.6
Heating infiltration (ACH) 0.8
..................... .......... .......... .............................- - ..........
Winter ventilation 0
Summer ventilation 0
.. ... ..........
Design Conditions
Outdoor Heating Cooling
................................
On
Dry bulb (OF)
Daily range M
.....................
Relative humidity 50%
Moisture difference 53
............... ........................... ..........
Indoor Heating Cooling
.......... ............. ..........
Indoor temperature (OF) 70 75
-..................... ...............I I--- - -...................----.............
Design temperature differenceff) 38 18
'Heating Loads
Ar*ea Btuh % of load
.................... ................ ....................
Wall 3445 17.
Floor 4925 24.8
Ceiling 2070 10.4
Windows 2793 14.1
Infiltration 4795 24.2
System Efficiency Loss 1803 9.1
Total: 19831
Heat ng Loads
19,831 BTU/hr-
Systern ElficiencV Loss
ROO
Ceiling
wimclows
Infiltration
Coolinq Load
Area Btuh % of load
Wall 2538
Ceiling 2888 12.6
Windows 8196 35.7
Sensible Infiltration 1704 7,4
Latent I nfiltrati on 3101 13.5
System Efficiency Gain 1843 8
Internal 1748 7.6
Sensible People Load 460 2
Latent People Load 460 2
Total: 22937
Sensible load 19376
Latent load 3561
SHR 0.84
Capacity at .75 SHR 2.15 Tons
............................ 1-1.1-............
Cool i ng Loads
22,937 BTUN
Sensible People Load
Latent People Load
Sensible Infiltration
Internal
Windows
System Efficienc,.
wall
Latent Infiltration Ceiling
,Adequate Exposure Diversity
AED Graph
10000
7500
5000
2500
0 8am 9am 10am 11am 12pm 1PM 2pm 3pm 4pm SPM 6P111 7pm SPM
Hourly Loads —Average -J,
Equipment selection
System equipment selection will be made using the following derived values.
Glass (E) 75 sq. ft.
.............. ............. ........................... .............................
Glass (S) 10 sq. ft.
Glass (N) 10 sq. ft.
Glass (W) 52 sq. ft.
Summer Outdoor 930F
---.................................................................- ................................................ ................. .................. .....................- --.- - -...... ..................
Summer Wet Bulb 77"F
Summer Indoor 750F
..........-
Summer Design Grains 50%
Winter Outdoor 320F
--........................................... ............
Winter Indoor 70"F
Sensible Cooling 19,376 Btuh
Latent Cooling 3,561 Btuh
Required Cooling Airflow 881 CFM
Sensible Heating 19,831 Btuh
-1-1-1................ .."...... ..........- .............. ................
Required Heating Airflow 258 CFM
All calculations are based upon approved hvac industry standards and procedutes,and comply with all local,
state and federal code requirements.All computed results are Estirnates.Product provided by Energy Design
Systems and Idea Tree
mommommoomm���-
*' C FIEDT
ERTI
www.ahridirectory.org
Certificate of Product Ratinos
AHRI Certified Reference Number: 5583691 Date: 7/3/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130241B*
Indoor Unit Model Number: ARUF24B14B*
Manufacturer: GOODMAN MANUFACTURING CO.. LP.
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING ND
Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 23000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh)@ 47 F: 21600
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh)@ 17 F: 13500
Ratings followed by an asterisk(*)indicate a voluntary refate of previously published data-unless accornvanied with a WAS.wbich indicates an involuntary rerate-
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the prociuct(s)listed on this Certificate.AHRI expressty disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at :�ridirectory�org.
TERMS AND CONDITIONS
-his Cerfificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.atindirecw "IMP, Air-Conditioning,Heating,
click on Certificate"link and enter the AHP Cerfified Reference Number and the date on BOU and Refrigeration Institute
which the certificate was issued.which is listed above.and the Certificate No.,which is listed below.
@2013 Air-Conditioning. Heating.and Refrigeration Institute CERTIFICATE NO.: 130173283705324450