Loading...
2263 N Fairway Villas 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 oil Application Number . . . . . 13-00002991 Date 7/03/13 Property Address . . . . . . 2263 N FAIRWAY VILLAS LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LANGFORD, ELIZABETH SNYDER HEATING & AIR PO BOX 2235 P.O. BOX 16826 TALLAHASSEE FL 32316223S JACKSONVILLE FL 32245 (904) 32S-9979 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/30/13 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 OB ADDRESS: Z-:L-US PERmrr# PROJECTVALUE $ LWO6.2' ARI# '55t?:,u(41 _REQUIRED —Air Handling Equipment Only ?( Air Handling Unit & Condenser Condenser Only iEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit _L_ Heat: Unit Quantity BTU'sPerUnit -z.�Acoo Seer Rating I Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or :)t. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Toperty Owners Name N Phone Number 15-11- �PLA LA 4echanical Company Office Phone UW-QkcooFax_�9�17�57-9 .o. Address: City Ite State C-L Zip 1��-Llt,;; ,icense Holder(Print): CLAw*,.e\ /State Certification/Registration# CACI'&IS2609- i6tarized Signature of License Holder 1A I/ Before 77 day of HOLLY A.FOUST MT17MISSION#EE 204856 Signature of Notary Pu�lic EXPIRES:July 21,2016 "*.Fle Bonded Thru Budget Notary SerAces DesignStar Load Calculation 40 Results are intended for use with Rheem heatinq and cooling systems Information Street Address 2263 fairway villas In n, Atlantic Beach, FL 32233 Latitude, Longitude 30.33750, -81.7686" House Square 1028 sq. ft. Footage: Name: joy martin ........... Phone: 123-123-1234 Email: example@maii.com ............... ....................- House Information SHR .75 Number of residents 2 Ceiling height 9 Wall U-value R-value 0.091 11 Floor U-value R-value 0.2 15 Ceiling U-value R-value 0.0531 19 Window U-value 0.5 Window SHGF 0.85 Moisture grains 53 ........... Ductloss % 10 Duct gain % 10 .......... ................ .............................. ....................................................................... .............. ................ Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 ..................... .......... .......... .............................- - .......... Winter ventilation 0 Summer ventilation 0 .. ... .......... Design Conditions Outdoor Heating Cooling ................................ On Dry bulb (OF) Daily range M ..................... Relative humidity 50% Moisture difference 53 ............... ........................... .......... Indoor Heating Cooling .......... ............. .......... Indoor temperature (OF) 70 75 -..................... ...............I I--- - -...................----............. Design temperature differenceff) 38 18 'Heating Loads Ar*ea Btuh % of load .................... ................ .................... Wall 3445 17. Floor 4925 24.8 Ceiling 2070 10.4 Windows 2793 14.1 Infiltration 4795 24.2 System Efficiency Loss 1803 9.1 Total: 19831 Heat ng Loads 19,831 BTU/hr- Systern ElficiencV Loss ROO Ceiling wimclows Infiltration Coolinq Load Area Btuh % of load Wall 2538 Ceiling 2888 12.6 Windows 8196 35.7 Sensible Infiltration 1704 7,4 Latent I nfiltrati on 3101 13.5 System Efficiency Gain 1843 8 Internal 1748 7.6 Sensible People Load 460 2 Latent People Load 460 2 Total: 22937 Sensible load 19376 Latent load 3561 SHR 0.84 Capacity at .75 SHR 2.15 Tons ............................ 1-1.1-............ Cool i ng Loads 22,937 BTUN Sensible People Load Latent People Load Sensible Infiltration Internal Windows System Efficienc,. wall Latent Infiltration Ceiling ,Adequate Exposure Diversity AED Graph 10000 7500 5000 2500 0 8am 9am 10am 11am 12pm 1PM 2pm 3pm 4pm SPM 6P111 7pm SPM Hourly Loads —Average -J, Equipment selection System equipment selection will be made using the following derived values. Glass (E) 75 sq. ft. .............. ............. ........................... ............................. Glass (S) 10 sq. ft. Glass (N) 10 sq. ft. Glass (W) 52 sq. ft. Summer Outdoor 930F ---.................................................................- ................................................ ................. .................. .....................- --.- - -...... .................. Summer Wet Bulb 77"F Summer Indoor 750F ..........- Summer Design Grains 50% Winter Outdoor 320F --........................................... ............ Winter Indoor 70"F Sensible Cooling 19,376 Btuh Latent Cooling 3,561 Btuh Required Cooling Airflow 881 CFM Sensible Heating 19,831 Btuh -1-1-1................ .."...... ..........- .............. ................ Required Heating Airflow 258 CFM All calculations are based upon approved hvac industry standards and procedutes,and comply with all local, state and federal code requirements.All computed results are Estirnates.Product provided by Energy Design Systems and Idea Tree mommommoomm���- *' C FIEDT ERTI www.ahridirectory.org Certificate of Product Ratinos AHRI Certified Reference Number: 5583691 Date: 7/3/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ130241B* Indoor Unit Model Number: ARUF24B14B* Manufacturer: GOODMAN MANUFACTURING CO.. LP. Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST, ONE HOUR AIR CONDITIONING ND Manufacturer responsible for the rating of this system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh)@ 47 F: 21600 Region IV HSPF Rating (Heating): 7.70 Heating Capacity(Btuh)@ 17 F: 13500 Ratings followed by an asterisk(*)indicate a voluntary refate of previously published data-unless accornvanied with a WAS.wbich indicates an involuntary rerate- DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the prociuct(s)listed on this Certificate.AHRI expressty disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at :�ridirectory�org. TERMS AND CONDITIONS -his Cerfificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.atindirecw "IMP, Air-Conditioning,Heating, click on Certificate"link and enter the AHP Cerfified Reference Number and the date on BOU and Refrigeration Institute which the certificate was issued.which is listed above.and the Certificate No.,which is listed below. @2013 Air-Conditioning. Heating.and Refrigeration Institute CERTIFICATE NO.: 130173283705324450