Loading...
465 Beach Ave HVAC 2013 CITY OF ATLANTIC BEACH. y 800 SEMINOLE ROAD j � ATLANTIC BEACH,FL 32233 i INSPECTION PHONE LINE 247-5814 13-00003045 Date 7/12/13 Application Number . 465 BEACH AVE Property Address . • • Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . 0 ------------------------- Application desc 1 CU 1 AHU 2 TONS ------------- ------------------------- Contractor Owner ----------- VETT W RADFORD II ENVIRONMENTAL A/C SERVICES, IN LO VETT AVE 8110 CYPRESS PLAZA DR STE 106 FL 322335321 JACKSONVILLE FL 32256 ATLANTIC BEACH (904) 279-0030 __ _ -- -----Permit---- • MECHANICAL HVAC PERMIT Additional desc . Plan Check Fee . 00 Permit Fee . . . . 91 . 00 0 Valuation • Issue Date • • ' ' 1/08/14 Expiration Date . _____ -------------------------- --- 2 . 00 Other Fees . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE ---- --- ----------------- ------------------ ------ Due Fee summary Charged Paid Credited --------- ---------- . 00 00 Permit Fee Total 91 . 00 91 . 00 00 . 00 Plan Check Total • 00 4 . 00 4 . 00 . 000 0 . 00 Other Fee Total 95 . 00 . 00 . 00 Grand Total 95 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 07/11/2013 14:32 9042790078 ENVIRONMENTALAIRCOND PAGE 01 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904)247-5826 Fax(904) 247-5845 JOB ADDRESS: 465E ACH AVENUE,ATLANTIC BEACH,FL 32233 PERMIT# PROJECT VALUE $ 5271.00 ARI#_5297$$7 REQUIRED Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin-RE QUfRED Duct Systems: otal CFM REPLACEMENT A CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: nit Quantity 1 Tons Per Unit 2 Heat: Unit Quantity I BTU's Per Unit 24000 Seer Rating 13.00 Duct Systems: Total CFM REQUIRED FIRE PREVENTIO Re uires 3 sets of plans) Fire Sprinkler Syste Quantity {Requires 3 sets of lans Fire Standpipe Q �' Underground Fire M in Value (Requires 3 sets of(Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts BTU's Gas Piping Outlets Boilers Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's ,_ # Water Heaters - Solar Collection Systems Tanks (gallons) "Wells DTHER: t I have road 'inapt li becomes void pow the same to be trucence a�nd correct All provisions six mo th ood l s and ordinances governor ing this abandoned work wr six lill be complied with whether specified or is suspen his application and know pot. The permit does not give authority to violate the provisions of any other state or local lay regulation construction or the performance of construction. ?roperty Owners Name Radford Lovett Phone Number 904-993-0303 Mechanical Company Fnvirontnental Air Conditioning Services,Inc. Q£fice Phone 904-279-0030 Fax 904-279-0078 � o. Address: $1 0 C cess Plaza Drive City Jacksonville State FL Zip 32256 Suite 106 License Holder(print): Howard K. Stalls Jr. State Certification/Registratian# C,4C057409 Votarized Signature of License Holder Eb�Refore me this 1 Ith ay o July 20I3 "' ;: �mmisaion#oo 972ill7 iJmj fw 7 °°'0' gnature of Notary P .' 07/11/2013 14:32 9042790078 ENVIRONMENTALAIRCOND PAGE 02 Job: Project Summary Date: 317113 Zone 4-3rd Floor By: M.Etlls Energy Design Systems, Inc. 12132 Wealhenood Eatetes Dr W.Jacksonv1110,Ft..32223 Phone.904-288.3870 Fax 904-2eB-3e70 EM8114Ss40112fil?VIAM-1 For: Radford Lovett 455 Beach Avenue Atiantilc Beach, FL 32233 Notes: f�rarit Door Faces West � . MIA . • Weather; Jacksonville Intl AP, FL, US Winter Design Conditions Summer Design Conditions 32 'F Outside db 94 of 74 Outside db OF inside db 74 OF Inside db Design TD 20 OF Design TD 42 of M taaily range 50 d� Relative humidity 52 gr/lb Moisture difference Heating Summary Sensible Cooling Equipment Load Sizing 11939 Stuh Structure 17970 Btuh Structure 0 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent( cfm} 0 Btuh Blower 0 Btuh HumidificatiO 0 Btuh Piping 11939 Btuh Use manufacturer's data n Equipment to d Rate/swing multiplier 0.99 Infiltration Equipment sensible load 17862 Stuh Method Simplified Latent Cooling Equipment load Sizing Construction quality Semi-loose 3708 Btuh Fireplaces 0 Structure 0 Stuh Ducts Btuh Heating Cooling Central vent(0 cfm) 370 0 0 Stuh Area{ftp} 1162 1162 Equipment latent load Volume(ft') 9296 9298 21570 Stuh hngecapacity at 0.75 SHR 2.0 ton sl�tour 0,38 0.20 Air8 Equipment total load Air ch ri F ( m) 59 31 Req. total Heating Equipment Summary Cooling Equipment Summary Make Trane Trane Make Trade XR15 WEATHERTRpN Trade XR15 WEATHERTRON Cond 4TWR5024G1 Model 4TWR5024131 Coil `AM7AOA24H21 AHRI ref 5020724 AHRI ref 5020724 9 HSPF Efficiency 13 0 EER, 15.5 SEER Efficiency Sensible cooling 16758 Btuh Heating input 7182 tuh Heating output 21600 Btuh @ 47°F Latent coaling 23940 Btuh 25 OF Total cooling 787 cfm Temperature rise 787 cfm Actual air flow 0.044 cfm/Btuh Actual air flow 0.066 cfm/Btuh Air flow factor 0 in H2O Air flow factor 0 in H2O Static pressure Static pressure Load sensible heat ratio 0.83 Space thermostat Calculations approved by ACOA to meet all requirements of Manual J 8th Ed. 2013 Mr.OB 18.38:38 Fggg 4 wrightSOft" Rlght•SWtaab Universal 2012 12.1.03 RSU17457 Galc=MJB Front()oor 1actm:SPeee 4 tRemdential Changeoul Manual J1rAG,4589 Ortega Blvd.Jex.ruP