1662 E Park Ter 2013 HVAC N CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003016 Date 7/11/13 Property Address . . . . . . 1662 E PARK TER Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 4 TONS 48K BTUS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ BROWN DAVID J & JANET A DONOVAN HEATING & AIR 1662 PARK TERRACE WEST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/07/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 10B ADDRESS: (o 6,2 i1ric I f�(z PERMIT# J5 I(Do 0-0 PROJECT VALUE $ ARI# crDO I Q'7_ —REQUIRED Air Handling Equipment Only �(_Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit q Heat: Unit Quantity BTU's Per Unit WFO-00 Seer Rating_ 15 Duct Systems: Total CFM REQUIRED ZIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ZIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name "DA-v C- "BrVVVn Phone Number 2fq-gg-79 Aechanical Company T)q Pep, fE A4Z Office Phone 1-W-YUS- Fax ,o. Address: AVE S city T4X 6CI- State A zi,)UM ,icense Holder(Print): lionn �Dn Into ri State Certification/Registration# -3 9-76 Votarized Si a Ider— :�j rida A5;r Before me*ifq 9 day of -rL11 40 W N Notary Pubfic state of Rorwa N 20 TOWthy Lee Hughes my convr"sion EE 186278 ExpiM 0"312016 Signature of Notary Public OFV� Job: wrightsoft Project Summary Date: 6/28/13 Entire House By: Brandon Zaharie Donovan Heat&Air 315 6th ave south, Jacksonville Beach, FL 32250 Phone 241-3785 Email brandon@donovanac.com Project Information For: BROWN 1662 PARK TERRACE EAST, ATLANTIC BEACH, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21477 Btuh Structure 17679 Btuh Ducts 7576 Btuh Ducts 15456 Btuh Central vent(57 cfm) 1804 Btuh Central vent (57 cfm) 1244 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30857 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 34379 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2029 Btuh Ducts 2778 Btuh Heating Coolin Central vent (57 cfm) 2047 Btuh Area (ft') 2336 2339 Equipment latent load 6854 Btuh Volume (ft') 21024 21024 Air changes/hour 0.38 0.16 Equipment total load 41233 Btuh Equiv.AVF (cfm) 132 56 Req. total capacity at 0.70 SHR 4.1 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model TXH548 Cond TXH 548 ARI ref no. 3650162 Coil FVM4X48 ARI ref no. 3650162 Efficiency 8.2 HSPF Efficiency 15 SEER Heating input Sensible cooling 32292 Btuh Heating output 45903 Btuh @ 47'F Latent cooling 13840 Btuh Temperature rise 27 OF Total cooling 46132 Btuh Actual air flow 1538 cfm Actual air flow 1538 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 41 Right-Suite@ Universal 7.1,01 RSU05996 2013-Jun-28 11�45 44 Page 1 C\Users\Sales\Documents\Wrightsoff HVAC\4 TON.rup Calc=MJ8 Orientation=N