Loading...
768 Aquatic Dr 2013 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003089 Date 7/18/13 Property Address . . . . . . 768 AQUATIC DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ MORRIS DONOVAN HEATING & AIR 768 AQUATIC DRIVE 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/14/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 (OB ADDRESS: 76 u a T1 G ' { PERMIT# Or PROJECT VALUE $ 345(4 ARI# S-7760/5' REQUIRED Air Handling Equipment Only _KAir Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity_ BTU's Per Unit. l Seer RatmL Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit /-3 Heat: Unit Quantity / BTU's Per Unit d 00 Seer Rating Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ?IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read lis application and know the same to be true and correct All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name r Phone Number 7¢7 --Iq b 7 dechanical Company ACATr 44 Office Phone z ffnf "Fax 374y :o. Address: �� _ City Jam' State�1 Zi2�S�0 .icense Holder(Print): l O State Certification/Registration# Jotarized Signature of License Holder efore hire this 7 day of v/ 20 yEiKi State of Florida T Hughes i ature of Notary Public % on EE 188278 � `"`�/2018 ,��{� Job: -�(+� wrightsoft Project Summary Date: 7/17/13 Entire House By: Brandon Zaharie Donovan Heat&Air 315 6th ave south, Jacksonville Beach, FL 32250 Phone 241-3785 Email brandon@donovanac.com Project • • For: Moms 768 Aquatic Dr,Atlantic Beach, FL 32233 Notes: DesignInformation Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 o Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13919 Btuh Structure 11729 Btuh Ducts 2799 Btuh Ducts 5690 Btuh Central vent(12 cfm) 370 Btuh Central vent (12 cfm) 255 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17088 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1638 Btuh Ducts 973 Btuh Heating Cooling Central vent(12 cfm) 420 Btuh Area (ftz) 1152 1152 Equipment latent load 3031 Btuh Volume (ft3) 10368 10368 Air changesthour 0.57 0.23 Equipment total load 20706 Btuh Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model N41-1324 Cond N41-1324 ARI ref no. 5778015 Coil FEA4X24 ARI ref no. 5778015 Efficiency 7.7 HSPF Efficiency 13 SEER Heating input Sensible cooling 15747 Btuh Heating output 22384 Btuh @ 47°F Latent cooling 6749 Btuh Temperature nse 27 °F Total cooling 224. u.. Actual air flow 750 cfm Actual air flow 750 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified byACCA to meet all requirements of Manual J 8th Ed. wrigf�tsott Right-SuiteQtl Universal 7.1.01 RSU05996 2013-Jul-17 16:02:09 AC(>` C:\Users\Sales\Documents\Wrightsoft HVAC\2Ton.rup Calc=MJ8 orientation=N Page 1