46 15th St 2013 HVAC CITY OF ATLANTIC BEACH
s) 800 SEMINOLE ROAD
►� .; ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003088 Date 7/18/13
Property Address . . . . . . 46 15TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 CU 1 AHU
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
BOENEKE ROBERT & DEMORY HUXHAM HEATING & AIR
7093 OX BOW RD 2101 FLORIDA BLVD.
TALLAHASSEE FL 32312 NEPTUNE BEACH FL 32266
(904) 246-6721
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 107 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/14/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 107 . 00 107 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 111 . 00 111 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-584-5
.TOB ADDRESS' / ! LS /-- �`� `vim PERMIT#
PROJECT VALUES (��900
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTTA#L TION
Air Conditioning: Unit Quantity ' Tons Per Unit _ REQUIRED
Heat: Unit Quantity ! BTU's Per Unit M 600 Seer Rating IS
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace QtyAutomobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of
Pumps
#VeneWall Furnaces Refrigerator
rator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER'
Permit becomes void if work does not commence within a sx month period or work is sanded or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct All provisions of laws and wdmances governing this work will be complied with whether specified
or not. The permit does not give authority to violate the provisions of any other state or local law regulation confliction or the performance of construction.
Property Owners Name ' r Crt1 Kf_ Phone Number
Mechanical Company Office Phoned (r I I Fax2yt/ 'C_3
Co. Address: �� t �G�� vCity � _ O lj State f/• Zip 3
License Holder(Print): �M4
�j� State CerfifiZon/Registration# 057�'l 5
Notarized Signature of License S )
w�o�n d subscribed befo this d o 20�3_
tore of Notary Publi
Job: 71713
-' x Project Summa Date: Jul 17,2013
enerav consultir;Cri Entire House By: ERIN RODRIGUEZ
Proiect Information
For: BOENEKE
46 15TH STREET,ATLANTIC BEACH, FL 32233
Notes: HUXHAM -A/C CHANGE OUT
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 92 'F
Inside db 68 'F Inside db 74 °F
Design TD 29 'F Design TD 18 °F
Daily range L
Relative fiumidity 50 %
Moisture difference 60 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16276 Btuh Structure 23272 Btuh
Ducts 8004 Btuh Ducts 11169 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 24280 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 33407 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Tight
Fireplaces 1 (Average) Structure 885 Btuh
Ducts 3011 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft') 1800 1800 Equipment latent load 3896 Btuh
Volume(ft') 14400 14400
Air changes/hour 0.26 0.09 Equipment total load 37303 Btuh
Equiv.AVF (cfm) 63 22 Req. total capacity at 0.70 SHR 4.0 ton
Heating Equipment Summary Cooling Equipment Summary
ant Make Bryant
IT ade LLake EGACY LINE PURON HP Trade LEGACY LINE PURON HP
Model 215BNA048
**** Cond 215BNA048"""""
AHRI ref 4843469 Coil FX4DN(B,F)049
AHRI ref 4843469
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 33250 Btuh
Heating output 45500 Btuh @ 47'F Latent cooling 14250 Btuh
Temperature rise 26 'F Total cooling 47500 Btuh
Actual air flow 1583 cfm Actual air flow 1583 cfm
Air flow factor 0.065 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2013-Jul-17 11:32:39
y,� -I-I+ wrightsoft Right-Suite®Universal 2012 12.1.08 RSU01508 Page 1
.JC.k ...s\WrightsoftHVAC\TemplateWUXHAM-BOENEKE.rup Calc=MJ8 FrontDoorfaces: N