Loading...
350 3rd St HVAC 2013 CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 ' INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003028 Date 7/10/13 Property Address . . . . . . 350 3RD ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 4TONS 48K BTUS ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- MERENDINO ROBERT D & JANET NICK' S SOLAR & AIR SYSTEMS 350 3RD ST 4891 TIMIQUANA RD ATLANTIC BEACH FL 322335232 JACKSONVILLE FL 32210 (904) 868-0624 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 107 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/06/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due Permit Fee Total 107 . 00 107 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 111 . 00 111 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 Vj JOB ADDRESS: 0 PERMIT# PROJECT VALUE $ %D® NEW AIR CONDI t IONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: UnitQ Y uantit BTU's Per Unit Seer Ratin Duct Systems: Total CFM AEQUIRED REPLACEMENT IR CONDITIONING & HEATING SYSTEM INSTALLATION , ARI# Air Conditioning: Unit Quantity Tons Per Unit REQUI ED / Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Firep ace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furr aces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not giN e authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Namev Phone Number Mechanical Company S A-fAnD� I- (• Office Phone 3/.S Fax" 3�18 bS V Co. Address: q ) City h Q State Zip 3�u License Holder(Print): MfNl 1 C Ck State erti at on/Registration 4CAco%9581 Not ature of License Holder ,L. LowuNE s.VIGIL MY COMMISSION#EF 059650 Sworn and subscribed before me this day of �! 20 J EXPIRE Th , Bon S:Fpua;c ebn;ary ginUn, m Signature of Notary Pub ded ru Notary I Ill Certificate of Product Ratings AHRI Certified Reference Number: 3605269 Date: 7/10/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13PJL48 Indoor Unit Mo el Number: RHSL-HM4821+RCSL-H*4821 Manufacturer: UUD AIR CONDITIONING DIVISION Trade/Brand nal e: RUUD 13PJL SERIES Manufacturer responsible for the rating of this system combination is RUUD AIR CONDITIONING DIVISION Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 46500 EER Rating (Cooling): 10.50 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 46000 Regio IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 30600 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a wAs,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the productls)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at Aww,ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at ,vm.ahridirectory.or, A " Aif-Conditioning,Heating, click on"Verity Certificate"link and enterthe AHRI Certified Reference Number and the date on �. `■ � and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130179248254279638 I RUUg) Desi nstar Load Calculation Results are intended for use with Ruud heating and cooling systems �Customer Information Street Address 350 third stf Atlantic Beach, FL 3223- Latitude, Longitude 30.3375", -81.7686" .. .- Neuse Square Footage: 2253 sq. ft, Name: Tone: 123-123-1234 Email: example@maii.com • Information SHR 1.75 Number of residents 2 Ceiling heigkt 9 . . ............. .. _. .._ Wall U-value R-value a09 11 Floor U-value R-value 0.2 5 Ceiling U-value R-value 0.053 j 1 Window U-v lue 0.5 Window SHGF 0.85 Moisture grins 53 Duct I oss 'f 10 Duct gain I© 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 Summer ventilation 0 i � esiqn Conditions Outdoor Heating Cooling Dry bulb ff) 32 93 Daily range M Relative humidity 50% Moisture difference 53 Indoor Heating Cooling ...................._..._._.._.._;..............................._ .. _. . ......._._...._............_...._.._...._..._............._......._.._......_.__ .1.1...._1..1.._..__............_....._....... Indoor temperature (°F) 70 75 Design temperature difference ff) 38 18 ..... _ . _ _ Heatinq Loads Area Stu % of load Wall 4739 11.7 Floor 10784 26.7 Ceiling 4538 11,2 Windows 6137 15.2 Infiltration 10510 26 System Efficiency Loss 3671 9.1 Total; 40379 Heating Loads 40,379 BTU/h, System Efficiency Loss Y Floor g�Ceiling Wall Infiltration Windows E Area Btuh % of load Wall 3492 4 Ceillno 6329 13,5 Windows 17954 38,E Sensible lnl i'(Taz, 7D 4 3 Latent lntiltrat, r 6796 1.4.E ystern. . . 3830 8.2 internal 3830 � 1 a );le Load 460 Latent People Load 460 Vita 1: :: Sonsi le to ', .3 50629 Latent load 7256 HR M5 Capacity at 75 SHR 4.40 Tons Cooling Loads Sensible People Load r Latent People Load Wall Sensible Infiltration gp- 3� Windows —Internal System Efficiency Ceiling Latent Infiltration 'Adequate Exposure AED Graph 25000 .. 20000 .... ........... . ........................ .... ......... _ _............... 15000 ............. .. ...... ...... _.. ........... m 4 1 10000 .......... ..._...... ..._..... .__........_... ...__. .................. .........._.... .......... ........ ................... _. ............. 5000 __ _.__..._. ...._.__ __..._.__ .......... 8am gam loam Ilam 12pm 1pm 2pm 3pm 4pm 5pm 6pm 7pm Bpm l—Hourly Loads —Average Equipment • System equipment selection will be made using the following derived values. Glass (E) 163 sq. ft. Glass (S) 23 sq. ft. Glass (N) 23 sq. ft. Glass (W) 114 sq. ft. Summer Outdoor 93°F Summer het Bulb 770F Summer Indoor 75"F Summer Deign Grains 0% Winter Outdoor 32°F Minter Indoor 700E Sensible Coding 39'629 Btu1..h Latent Cooling 7,236 Btuh Required Cooling Airflow 1,801 CFM Sensible beating 40,379 Btuh Required beating Airflow 524 CFM All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal cCsde requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree I