Loading...
170 Poinsettia St 2013 move exterior wall AMY KOONS CODE SUMMARY SCOPEOF WORK: FLORIDA BUILDING CODE (2010) DEMO EXISTING WALLS AS SHOWN & BUILD-OUT -'- E P AIR EXISTING COVERED AREA 0 RIGHT LEFT EXISTING STRUCTURE w/ CONCRETE FOUNDATION, WOOD FRAME WALLS, FLORIDA RESIDENTIAL CODE (2010) & CEMENTIOUS VENEER STUCCO for FLORIDA PLUMBING CODE (2010) 170 POINSETTIA ST. ATLANTIC BEACH FL. FLORIDA MECHANICAL CODE (2010) AMY KOONS 0 NATIONAL ELECTRICAL CODE (2008) SQUARE FOOTAGE TOTAL: 46 sq.ft SQUARE FOOTAGE INFORMATION * CONDITIONED SPACE 46' S.F. 170 P1, OINSETTIA STO 0 01 CONTRACTOR SHALL VERIFY ALL UNCONDITIONED SPACE S.F. of CONDITIONS AND DIMENSIONS 0 UNENCLOSED SPACE S.F. AT THE JOB SITE AND NOTIFY THE ATLANTIC '117) EAU - -i -FL * 322 �r__) �_) ARCHITECT OF ANY LOT AREA (EXCLUDING WETLANDS AND S.F. or ACRES DIMENSIONAL ERRORS , OMISSIONS BODIES OF WATER) OR DISCREPANCIES BEFORE BEGINNING OR FABRICATIING ANY WORK. STRUCTURE HEIGHT AND OF STORIES- THESE DRAWINGS ARE THE , PROPRIETARY WORK PRODUCT N/A PLAN INDEX MAXIMUM HEIGHT OF THE STRUCTURE: AND PROPERTY OF VERMEY ARCHITECT , DEVELOPED FOR THE A 2 �p COVER SHEET NUMBER OF STORIES: EXCLUSIVE USE OF VERMEY A-2 ELEVATIONS & FRAMING PLAN ARCHITECT . USE OF THESE A-3 FLA DRAWINGS AND CONCEPTS SHING & STANDARD DETAILS CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF Ayh VERMEY ARCHITECT IS TYPE OF CONSTRUCTION 1A PROHIBITED AND MAY SUBJECT Im YOU TO A CLAIM FOR DAMAGES - OCCUPANCY. R.3 gg. FROM GERARD VERMEY TYPE OF CONSTRUCTION: Y B SPRINKLED NO REVISIONS : f ie I AAA 10 MATERIAL INFORMATION 90 n ",c"k ROOFING (MATERIAL SHALL MEET THE THE REQUIREMENTS OF CHAPTER 1b, OF THE 2010 FLORIDA BUILDING CODE. AND THE 2010 C If 3mckMsonmv 21 FLORIDA RESIDENTIAL CODE CHAPTER 9. j ey A Ve rm rchitect X gr WIND ZONE INFORMAT11ON 13 21 _0 420 Third St. South NOTE: THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH, A"R AND MEETS THE REQUIREMENTS OF SECTION 1600 OF THE Jacksonville Beach , Fl . 2010 EDITION OF THE FLORIDA BUILDING CODE. 110534 32250 Aw THIS BUILDING IS LOCATED IN THE WIND BORNE DEBRIS REGION (904)246 - 1150 PROJECT LOCATION 130 BASIC WIND SPEED (M.P.H. 3-SECOND GUST) WIND IMPORTANCE FACTOR: 1.0 too WIND EXPOSURE CATEGORY. B BUILDING CATEGORY: PROJECT LOCATION INTERNAL PRESSURE COEFFICIENT: .18 COMPONENT & CLADDING (P. S. F. ) Lic. No. : AR4630 NLIMITE (904) 757 - 6137 SIZE END ZONE (5) INTERIOR ZONE (4) Drawn By: z �N (S.F.) 0 WD POS. + NEG. POS. + NEG. — Z 0-20 30.4 40.7 30.4 33 0 Reviewed By: U U50 _.q GV 20-50 29 38 29 31.6 0 <7� Draw Date: 50—loo 27.2 34.3 27.2 29.8 06 / 06 / 12 >100 25.9 31.6 25.9 28.4 5 Print Date: LAJ 06 / 06 / 12 END ZONE 3 Page: . ...... A — 1 of 3 AMY KOONS 170 POINSETTIA ST. R PO U TOP ATLANTIC BEACH FL. P T E#I SQUARE FOOTAGE F!W UNE OPTIONAL ROOF DESIGN—\ NDOW m E)aSTIN1 PATIO TOTAL: 46 sq.ft LIMITS OF WORK NEW 6068 S.G.D. DEMO PLAN CEMENTIOUS VENEE STUCCO' AREA USE N.T.S. TO BE DETERMINED / '(MATCH EXISTING) CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE TABLE FOR SHEAR WALLS FRAMING ARCHITECT OF ANY FRAMING LEGEND - - - - - - - - - - - Z/ EXISTING WALLS THE SHEAR WALLS TABLE WAS ESTABLISHED ASSUMING THE FOLLOWING CRITERIA UNLESS OTHERWISE DIMENSIONAL ERRORS, OMISSIONS PROPOSED COVERED AREA NEW ENCLOSURE (TO REMAIN) NOTED IN THE TABLE: OR DISCREPANCIES BEFORE (120 sq.ft.) (EXISTING PATIO) 2X6 0 16"O.C.SPF#2 A) WOOD SHEATHING Td STUDS NAILING SHALL BE 8d COMMON NAILS. BEGINNING OR FABRICATIING ANY EXTERIOR WALLS EXISTING HOUSE _j B) GYPSUM BOARD TO STUDS NAJILING SHALL BE 5d AND 6d COLLAR NAILS FOR 1/2" AND 5/8" THICK WORK, BOARD RESPECTIVELY. C) SOLE PLATE-CONCRETE SLAB ANCHORS LOCATED 0 6" (MIN.) EA. SIDE OF PLATE BREAK, ANCHOR SHALL BE 1/2" x 8" EPDXY GROUTED BOLTS, THESE DRAWINGS ARE THE D) 1/2" ALL-THREAD STRONGBOLT SYSTEM AS PER DETAIL ELEVATION PROPRIETARY WORK PRODUCT FOOTAGE AND PROPERTY OF VERMEY K" V-0" NEWENCLOSURE 46' DESIGNATION REQUIRED SINGLE OR SHEATHING TO STUDS ARCHITECT, DEVELOPED FOR THE SHEATHING DOUBLE SHEATHING NAIL SPACING EXCLUSIVE USE OF VERMEY NEW H&C: 46' NEW UNDER ROOF: 01 ARCHITECT. USE OF THESE NEW SLAB: 46' -'\2x4 WOOD FRAME 7/16"OSB SINGLE 4"/8" DRAWINGS AND CONCEPTS rA (BLOCKED) CONTAINED THEREIN WITHOUT THE WRITTEN PERMISSION OF 2x6 WOOD FRAME 7/16"OSB SINGLE 4-/8" VERMEY ARCHITECT IS (BLOCKED) GENERALNOTES: PROHIBITED AND MAY SUBJECT PROJECT SUMMARY: NOTE: ALL EXTERIOR WALLS SHALL BE SHEAR WALLS YOU TO A CLAIM FOR DAMAGES ENCLOSE EXISTING PORCH SPACE FROM GERARD VERMEY. DEMO EXISTING WALLS AS SHOWN NEW WOOD FRAME CONSTRUCTION REVISIONS : CEMENTIOUS VENEER-STUCCO on 2x6 WOOD FRAME WALLS EXISTING V-0"CEILING HGT. HOUSE F.F.ELEV.SHALL BE 8"ABV.GRADE(MIN) EXISTING ROOF SYSTEM (MATCH EXISTING) TO REMAIN EXISTING ELECTRICAL ITEMS TO REMAIN CEILING FINISH AS PER OWNER CONCRETE PARKING&SIDEWALKS NOT SHOWN ELECTRICAL LEGEND 0 110 OUTLET WALL MOUNT EXISTING 2nd FL. EXTERIOR WALL Vermey Architect OGFI 110 OUTLET-GROUND FAULT 420 Third St. South 0 AM 110 OUTLET-ARC FAULT CIRCUIT INTERRUPTOR w mZ EXISTING 2nd FL. FLOOR JOIST 0 Jacksonville Beach , Fl . U- SWITCH SINGLE POLE 2� � IiIATH D 32250 20- SWITCH DOUBLE POLE 0 (904)246- 1150 a. EXISTING BEAM -- — — — — — — — — — -j_ _ HOUSE WALL MOUNT LIGHT FIXTURE SURFACE MOUNT LIGHT FIXTURE SIMPSON "MSTA24" STRAP or - 0 16" D.C. N'11�DBL. 2"x6" SYP. TOP PLATE ATTACHED -NEW STUD TO BEAM- w/(2) 12d NAILS 0 EXIST. FLOOR JOIST BLOCKING 0 SHEATHING BREAK NE� 32- C R SHEET ROCK PROPOSED __7 0 1 U RY OM FINISH as per HOMEOWNER COVERED AREA L NE 2x PO FIR L 1) NATIONAL ELECTRICAL CODE(2008) 2"x6" WOOD STUDS 0 16" D.C. (120 sq.ft.) I I I ALL EXTERIOR WALL SHEATHING SHALL BE NE Ey . �w_ E ST. 8' LI�O\ 2) ALL RECEPTACLES IN BATHROOMS, GARAGES,OR 7/16' A.P.A. RATED w/8d COMMON NAILS SIMPSON "SPH4" STRAP 15 (�EW 3" SOB) I OUTDOORS SHALL BE PROTECTED BY A GROUND 4" O.C. EDGE & 8" O.C. FIELD 00 M H EXIST F.F.) FAULT INTERRUPTION SYSTEM(GFI)AND AS NOTED BUILDERS WRAP----,,,,, or = 0 EA. VERT. STUD (16" O.C. MAX.) �c -STRAPSON SAME STUDS- ON THE DRAWINGS. VAN, DRILL & EPDXY 10"A" ANCHOR BOLT 2x6 P.T. BOTT. PLATE w/VAPOR BARRIOR 1 40 1 1 1 11 FCI 3) OUTLET BOXES IN WALL BETWEEN LIVING AREA w/ 6- (MIN.) EMBEDMENT INTO CONCRETE fHXIU bTt' wl NUT & 3"0"xA" WASHER NEW CONC. SLAB lo, EADER, AND THE GARAGE SHALL BE METAL OR U.I. 0 48- O.C. (MAX) & 6- (MAX) (MATCH EXISTING F.F. ELEV.) — — — — — — — — — — — - mmtlw� APPROVED PLASTIC, FROM SPLICE TYP. EA. SIDE (2)3(68 B 4) RECEPTACLES SHALL BE SPACED ACCORDINGLY Lic. No. : AR4630 SO THAT NO POINT ALONG THE FLOOR LINE IS MORE THAN 6'-0"FROM ANY OUTLET. NO N EXISTING CONC, SLAB —5'-2"— 9. loll 2'5' SPACES FURTHER APART THAN 12-0"UNLESS �_TO BE CUT 24" TO ALLOW Drawn By: ATTACH NEW WOOD WALL TO EXIST HOUSEJ \-ATTACH NEW WOOD WALL TO EXIST HOUSE OTHERWISE NOTED OR PER ANY SPECIFIC NEW FOOTING AS SHOWN WD w/ )16"x4" LAG-BOLTS 0 24" O.C. CODES. 12* 20"(D)xl2*(W) MONOLITHIC FOOTING W/ 'X6"x4" LAG-BOLTS 0 24" O.C. NEW 6' SLIDING GLASS DOOR \_w/(2)#5 REBAR CONT. Reviewed 5) SWITCH PLATED TO BE PLACED AT 42"ABOVE 24" CLff (DRILL & EPDXY INTO EXISTING SLAB FINISH FLOOR TO CENTER OF SWITCH (TYPICAL). 0 EXISnNG SLAB 6" MIN. EMBEDMENT 0 EA. END) GV 6) ALL BRANCH CIRCUITS THAT SUPPLY 125-volt, Draw Date: SINGLE-PHASE 15 AND 20 AMPERE RECEPTACLE 06/06/12 OUTLETS INSTALLED IN DWELLING UNIT BE ROOMS TYP . CUT SECTION (" I FRAMING & SHALL BE PROTECTED BY AN ARC-FAULT CIRCUIT ELECTRICAL PLAN INTERRUPTER(S) N.T.S. — 2 Print Date: 06/06/12 KIP 11-09P Page: A- 2 of 3 SEALANT BEAD BEHIND MOUNTING DBL. TOP PLATE HEADER & BEAM DEATIL AMY FLANG 1747777717777777M OPENING WIDTH HEADER SIZE # OF JACK STUDS EACH END # OF KING STUDS EACH END I FLASHING WEATHER �_FLASHING 4' 1'-0" to 4'-0" (2) 2x8 1 2 RESISTANT BARRIER 4' 4'-1" to 9'-0" (2) 200 2 2 SEALANT BEAD BETWEEN SEALANT BEAD BETWEEN " to 16'-0- (2) 202 3 2 FLASHING AND MOUNTING MOUNTING FLANGE L-L-_1 H FLANG AND FLASHING SECTION THROUGH WINDOW JAMB SECTION THROUGH WINDOW JAMB 01 w METHOD B-1 CL m SIMPSON "LSTA12" STRAP or = 0 32" O.C. METHOD A-1 z 0.1) Z)�2 8 (ONLY IF OPENING IS GREATER THAN 5'- (2) 2x SYP HEADER (ALL OPENINGS) w WEATHER RESITIVE BARRIER APPLIED PRIOR TO THE WEATHER RESITWE BARRIER APPUED PRIOR TO THE 170 POINSETTIA ST. WINDOW INSTALLATION. FLASHING APPLIED DM WINDOW INSTALLATION. FLASHING APPUED BEHIND THE FACE OF THE MOUNTING FLANGE. THE MOUNTING FLANGE. ATLANTIC BEACH FL. SIMPSON "LSTA24" STRAP 8 ----or = 0 CRIPPLE STUDS HEAD FLASHINGo m TO DBL. TOP PLATE EMBED BOTTOM OF THE HEAD FLASHING AGAJNST THE PREVIOUSLY APPLIED SEALANT (FLASHING GOES OVER THE ci SQUARE FOOTAGE SEALANT). EXTEND HEAD FLASHING BEYOND EACH JAMB FLASHING. FASTEN IN PLACE. --KING STUD AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP AS PER CHART OF WATER RESISTANT BARRIER AT THE HEAD. BOTT. PLATE- \—JACK STUD DOOR or WINDOW OPENING TOTAL: 46 sq.ft AS PER CHART FLASHING AT HEAD EXTENDS 1 ALL-THREAD ROD SYSTEM CABINET BLOCKING DETAIL BEYOND JAMB FLASHING (SEE ALL-THREAD DETAIL) JAMB SEALANT- CONTRACTOR SHALL VERIFY ALL APPLY CONTINOUS SEALANT TO THE MOUNTING FLANGES CONDITIONS AND DIMENSIONS AT THE TOP (HEAD) AND SIDES (JAMBS) OF WINDOW. EXTEND SEALANT AT JAMBS 4* ABOVE THE ROUGH OPENING AT HEAD. EMBED JAMB FLASHING INTO SEALANT WALL STUDS TO TOP PLATE AT THE JOB SITE AND NOTIFY THE w/(2) 12d NAILS 0 EA. STUD AND FASTEN IN PLACE. (FLASHING GOES OVER SEA") ARCHITECT OF ANY (2)12d NAILS DIMENSIONAL ERRORS, OMISSIONS 0 12" O.C.' NOTES: *SIMSPON "LSTA1 2" STRAP or @ 32" O.C. OR DISCREPANCIES BEFORE IS ONLY USED WHEN OPENING WIDTH IS GREATER TOP PLATE (2)2x- SYP. BEGINNING OR FABRICATIING ANY MIN. LENGTH 8'-0" THAN 5'-0" (WHERE APLLICWASLE) L WORK, JAMB FLASHINGo 4' MIN. SPLICE *NO HDR. STRAPPING IS REQUIRED WHEN ALL—THREAD EXTEND JANB FLASHING TO OVER LAP SILL FLASHING. ROD SYSTEM IS PRESENT EXTEND JAMB FLASHING 4" ABOVE ROUGH OPENING (UNLESS OPENING IS GREATER THAN 5'-0" WIDTH) THESE DRAWINGS ARE THE HEIGHT AS PER PLAN AT HEAD. TUCK TOP OF JAMB FLASHING UNDER THE FLAP OF WRB AT THE HEAD. y PROPRIETARY WORK PRODUCT AND PROPERTY OF VERMEY WINDOW 2x- STUDS 0 16" ARCHITECT, DEVELOPED FOR THE BUILDERS WRAP ON 7/16" OSB SHEATHING STUD TABLE EXCLUSIVE USE OF VERMEY J` STUD SPACING FOR EXTERIOR LOAD—BEARING WALLS ARCHITECT. USE OF THESE DRAWINGS AND CONCEPTS 0 io_0 CEILING NO. 2 SPF NO. 2 SYP NO. 1 SYP 777777 HEIGHT 2x4 CONTAINED THEREIN WITHOUT CEMNTIOUS VENEER (STUCCOj 2x6 2x4 2x6 2x4 2x6 THE WRITTEN PERMISSION OF HER RESISTANT BARRIER WALL SHEATHING 9 FT. 16pl O.C. 24" O.C. 16" O.C. 24" O.C. 16" O.C. 24" O.C. VERMEY ARCHITECT IS 10 FT. 12" O.C. 24" O.C. 16" O.C. 24" O.C. 16" O.C. 24" O.C. ANCHOR SYSTEM & WALL STRAPPING- 2x- P.T. BOTTOM PLATE PROHIBITED AND MAY SUBJECT NOTE@ AS PER WALL SECTION"'**,--, 11 FT. N/A 16" O.C. N/A 16" O.C. N/A 16" O.C. 8.1.1.1.4 USE THE FLASHING CUT FORMULAS TO DETERMINE THE LENGTH OF EACH STRIP OF FLASHING FOR YOU TO A CLAIM FOR DAMAGES Ljf�' 12 FT. N/A 16" O.C. N/A 16" O.C. 16" O.C. FROM GERARD VERMEY. EACH WINDOW. THE ASTM STANDARD REQUIRES A FLEXIBLE FLASHING MINIMUM ROLL WIDTH OF 9 IN, (230 N/A MM). WIDER FLASHING MATERIALS, (FOR EXAMPLE, 12 IN. (300 MM)) MAY BE USED, HOWEVER THE ACTUAL FT. -ADHESIVE TYPE FLASHING MOISTURE BARRIER 13 12" 0. A 1 600 A 16" O.C. CUT LENGTHS FIGURED BY USING THE CHART WILL INCREASE. THE USE OF SELF N/A C N O.C. N/ IS ACCEPTABLE. (FOR FUTURE DISCUSSION: SELF-ADHESfVE FLASHINGS CAN BE EFFECTIVE WITH WIDTHS WALL STUDS TO BOTTOM PLATE 14 FT. N/A 12" O.C. N A 12" O.C. N/A 16" O.C. LESS THAN 9 IN. (230 MM). SELF-ADHESIVE TYPE FLASHING SEALS ITSELF TO THE WEATHER RESISTANT w/ (4)12d NAILS (TOE NAILED)-\ BARRIER AND TO THE MOUNTING FLANGE WITHOUT THE NEED FOR ADDITIONAL SEALANT APPLIED TO THE 0 EA. STUD REVISIONS : EXTERIOR FACE OF THE FLANGE. SELF-ADHESIVE TYPE FLASHING MATERIALS MUST PROPERLY ADHERE, (CREATING A WATER TIGHT JOINT) TO THE (WRB) AND TO THE MOUNTING FLANGE MATERIAL IN ORDER TO BE ACCEPTABLE FOR USE. SEAL THE WINDOW FRAME TO OPENING. APPLY A DRILL & EPDXY 8"0/2" ANCHOR BOLT 3/8- NOM. DIA. TO THE BACKSIDE (INTERIOR) w/4* EMBEDMENT INTO CONC. OF THE WINDOW FLANGE. IN LINE WITH ANY w/ NUT & 3x3" SQ. WASHER PRE-PUNCHED HOLES OR SLOTS 0 48* D.C. (MAX.) & 6" (MAX.) FROM SPUCE. TYP. EA. SIDE GENERAL NOTES : SHIM AND ADJUST WINDOW TO ACHfVE SQUARE, PLUMB, AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER WINDOW EXTERIOR WALL FRAMING DETAIL ALL WORK SHALL CONFORM TO: MANUFACTURERS SPECIFICATIONS. N.T.S. FLORIDA BUILDING CODE 2007. SECTION 703 WALL COVERINGS FLASHING (STUCCO) FOOTING DESIGN IS BASED ON MIN. SOIL BEARING CAPACITY OF 2000 PSF AT 95% DENSITY, APPROVED CORROSION-RESISTIVE FLASHING SHALL BE PROVIDED IN THE EXTERIOR WALL ENVOLOPE IN SUCH A MANNER AS TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING STRUCTURAL FRAMING COMPONENTS. THE FLASHING SHALL EXTEND TO THE ALL CONCRETE WORK SHALL BE PREFORMED IN ACCORDANCE SURFACE OF THE EXTERIOR WALL FINISH AND SHALL BE INSTALLED TO PREVENT WATER FROM w/F.B.C. REQUIRMENTS Vermey Archited REENTERING THE EXTERIOR WALL ENVELOPE. APPROVED CORROSION-RESISTANT FLASHINGS SHALL BE INSTALLED AT, BUT NOT LIMITED TO, ALL THE FOLLOWING LOCATIONS: 2# 2# USE (3) ROWS ALL REINFORCING STEEL SHALL CONFORM TO F.B.C. REQUIRMENTS 1) FLASHING FOR WINDOWS AND DOORS SHALL BE IN ACCORDACE WITH SECTION R613.8. OF 1 Od COMMON 420 Third St. South USE (2) ROWS EQ. 2) AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONARY CONSTRUCTION WITH FRAME OR STUCCO OF 10d COMMON NAILS 0 112"O.C. MINIMUM COVER FOR REINFORCING SHALL BE 3" FOR FOOTINGS, Jacksonville Beach , FI . WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER STUCCO COPINGS. NAILS 0 12"O.C. STAGGER NAILS 3) UNDER AND AT THE ENDS OF MASONARY, WOOD OR METAL COPINGS AND SILLS. EQ, ON BOTH SIDES AND CENTERED IN SLABS. 32250 j— 2# 1 4) CONTINUOSLY ABOVE ALL PROJECTING WOOD TRIM. TYPICAL OF (2) 2"x6" REINFORCING BAR SPLICES FOR #5 BAR SHALL BE 30" MIN. (904)246 - 1150 THRU (2) 2"02" TYPICAL OF (3) 2"00" AND HOOKS SHALL MEET ACI STANDARDS. 5) WHERE EXTERIOR PORCHES, DECKS OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF thru (3) 2"02" WOOD-FRAME CONSTRUCTION. SOLID SAWN LUMBER ALL REINFORCING SHALL BE HELD SECURELY IN POSITION 6) AT WALL AND ROOF INTERSECTION w/STANDARD ACCESSORIES DURING PLACING OF CONCRETE. 7) AT BUILT-IN GUTTERS. ROOF TRUSS'ES AS PER MANUFACTURER 2# USE (3) ROWS USE (2) ROWS EQ, OF 1 Od COMMON EXTERIOR WALL SHEATHING OF 10d COMMON NAILS 0 12"O.C. NAILS 0 12"O.C. STAGGER NAILS EQ, I ON BOTH SIDES 2# 2# DRIP SCREED MIN. 4" ABOVE GRADE STUCCO 4" THICK CONC. SLAB 2x4 P.T. BOTT. PLATE (2) 1 -3Z4" PLY LVIL (3) 1 -3,Z4" PLY LVIL w/VAPOR BARRIOR SLAB GROUT SOLID AROUND PIPE .-a RADE 4# GRADE G /\\-OPTIONAL MONOLITHIC FOOTER — 3/8" BOLTS w/3"xl/8" 0 0 0 MONO-FOOTER Lic. No. : AR4630 SEE TYP. WALL SECTION 161 81 WASHERS 0 12" O.C. Drawn By: FOUNDATION 4# STRAPPING OF ALL BEAMS 1-SIMPSON MTS 16 EA. END WD EXTERIOR WALL SHEATHING SHALL BE RAISED OFF THE CONCRETE AND NOTE: ALIGNED WITH THE FACE OF THE FOUNDATION. IN AREAS WHERE THE BOTTOM SEE FOUNDATION FOR SIZE & LOCATION OF THE OSB IS EXPOSED IT SHALL BE EXTERIOR GRADE OR OTHERWISE Reviewed By: PROTECTED AS APPROVED BY THE BUILDING OFFICIAL. 4—PLY BEAM DETAIL 121 121 GV UTILITY CHASE/MONO — FOOTER Draw Date: STUCCO N.T.S. 06/06/12 MULTIPLE MEMBER D ETAI L. S T—T r� _n N.T.S. Print Date: _I 06/06/12 N—IF _.., ETAILS_ N.T.S. Page: A - 3 of 3 K001\ S 7rFLAi�INGI S 4 S _f_ff�__ 4 12 "C' X&-SYp- 'ABLE) 4CHOR BOLT ,.T AJEED DE F LA IN