123 Pine St 2013 HVAC 0, CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003100 Date 7/19/13 Property Address . . . . . . 123 PINE ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 2 CU 2 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ GARRETT KAREN S TROPIC HEATING & AIR 123 PINE ST 750 MAYPORT RD ATLANTIC BEACH FL 322334011 ATLANTIC BEACH FL 32233 (904) 241-1788 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 123 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/15/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 123 . 00 123 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 127 . 00 127 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 JOB ADDRESS: /,Z 3 51, PERMIT it Y&I q 53-s- PROJECT VALUE $ 71, c)0 o ARI# 34" 7/0 REQUIRED Air Handling Equipment Only 2-Air Handling Unit & Condenser Condenser Only I/ NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 4k, Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION t- - 5-0�bo I- �' Air Conditioning: Unit Quantity Z, A.01 Tons Per Unit 2- Heat: Unit Quantity BTU's Per Unit a vejo Seer Ratin2 /? , b Duct Systems: Total CFM ki./ac-0 _SW-,-1 REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other or local law regulation construction or the performance of construction. Property Owners Name Phone Number Mechanical Company -Office Phone2 W-06t Fax.�(fl--217� State R ZipTZ2,:1-3' Co. Address: _750 fx-,,N NA ��b city AiL License Holder(Print): (N�eAk State Certification/Registration# C4&V qu Notarized Signature of License Holder KAREN E.PANTFOEDER I q NOTARY PUBLIC Before me this day of j 11 ILA _ _20 STATE OF FLORIDA Comm#EE064"8 Signature of Notary Public J<Itw�d i�l I V" E)Vres 3/4/2015 1 It AVERS C E RT I F I E DT4' L_ www.ahridirectory.org 'A J Certificate of Product Ratings AHRI Certified Reference Number: 3699555 Date: 7/19/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)018****A Indoor Unit Model Number: FB4CNF018 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh)-. 17400 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F 17400 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F: 10500 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibilityfor, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectoryorg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products ofAHRI.This Certificate shall onlybe used forindividual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced�copied;disseminated;entered into a computer database:or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ME Theinformation forthemodel cited on this certificate ran beverified atwww.ahridirectoryorg, A Air-Conditioning,Heating, dickon"Verify Certificate"linkand entertheAHFZI Certified Reference Numberand the dateon AMU M ILI and Refrigeration Institute which the certificate was issued,which is listed above.andthe Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130187100599752255 CERTIFIEDTIA "i www.ah rid ire ctory.o r g 4 J Certificate of Product Ratings AHRI Certified Reference Number: 3699710 Date: 7/19/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 213BN(A,W)024****A Indoor Unit Model Number: FB4CNF024 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh)-. 23000 EER Rating (Cooling): 11.00 SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 22600 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh) @ 17 F 13600 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the prGduct(s)listed on this Certificate.AHRI expressty disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrid!rectory�org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION Theinformation forthemodel cited on this certificate can be verified at A' C nditioning,Heating, the date an 0%1 M click on"Verify Certificate"linkand entertheAHRI Certified Reference Numberand ILI anlrd Refrigeration Institute which the certificate was issued,which is listed above.and the Certificate No.,which is listed below. @2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130187099994576640 Job: Garrett Project Summary Date: 7/19/2013 Entire House By: Tropic Heating&Air C Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@m9n.00m Ucense:CAC-052431 Project Information For: Karen Garrett, Tropic Heating&AirConditioning,lnc. 123 Pine St, Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 'F Outside db 91 'F Inside db 70 'F Inside db 75 'F Design TD 35 'F Design TD 16 'F Daily range M Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 27731 Btuh Structure 17777 Btuh Ducts 5506 Btuh Ducts 7135 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33237 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 24912 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3653 Btuh Ducts 1632 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1836 1836 Equipment latent load 5285 Btuh Volume(ft) 18360 18360 Air changes/hour 0.50 0.26 Equipment total load 30197 Btuh Equiv.AVF (cfm) 153 80 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1032 cfm Actual air flow 1032 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-190512:49 wrightSOft Right-Suite@ Universal 2013 13.0.01 Right J@ Mobile Page 1 .\wstmp\63f07abl-ece4-465a-a4el-167ec2ebOlbf.rup Calc=MJ8 FrontDoorfaces W Job: Garrett Right J@ Mobile Report Date: 7/19/2013 # Entire House By: Tropic Heating&Air C... Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone 904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com Ucense:CAC052431 Project Information For: Karen Garrett,Tropic Heating&AirConditioning,lnc. 123 Pine St, Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email:Tropicac@msn.com Design Conditions Location: Indoor: Heatin;m Cooling Jacksonville/Craig, FL, US Indoor temperature(oF) 70 75 Elevation: 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb('F) 35 91 Infiltration: Dailyrange('F) - 17 ( M Method Simplified V�bt bulb('F) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 TOW Component Btu h/ft2 Btuh %of load Walls 3.4 9743 29.3 Dils Glazing 19.7 3649 11.0 \Adls Doors 20.8 666 2.0 Ceilings 1.7 1404 4.2 Floors 7.8 6456 19.4 ---1rfrTzbcn Infiltration 1.9 5814 17.5 Ducts 5506 16.6 Piping 0 0 Ga&g ID, Humidification 0 0 Dars r Ventilation 0 0 Cgirgs R03S Adjustments 0 Total i 332371 100.01 E- =�* Component Btu hN Btuh %of load Walls 1.5 4365 17.5 Glazing 26.8 4962 19.9 WAS, I rtand Gains Doors 17.6 564 2.3 Ceilings 2.6 2142 8.6 Floors 0 0 0 Infiltration 0.5 1424 5.7 Gaong Ducts 7135 28.6 Ventilation 0 0 Internal gains 4320 17.3 DLicts Blower 0 0 Adjustments 0 Ceilings Infiftiraticn Total 24912, 100.0, Latent Cooling Load 5285 Btuh Overal I U-va I ue=0.133 Btuh/ft2-'F Data entries checked. 2013-Jul-19 05:12:49 rr- wrightSOft Rig ht-Suitee U niv ersal 2013 13.0.01 Right J8 Mo bile Page 1 AC CA ...�wstmp\63f07abl-ece4-465a-a4el-167ec2ebOlbf.rup Calc=MJ8 Front Door faces: W Right-M) Worksheet Job: Garrett 10M Entire House Date: 7/19/2013 By: Tropic Heating&Air Condi Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone�904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 I Room name Entire House First Floor 2 Exposed wall 312�O ft 104.0 ft 3 Room height 10.0 ft d 10�0 It heat/cool 4 Room dimensions 34.0 x 18.0 It 5 Room area 18360 ft2 612.0 ft2 I I I I I I Ty � Construction U-value. Or I HTM Area (ft2) Load Are (ft2) Load number (Btuh/W� F) (Bt uh/f t2) or perimeter (ft) (Btuh) or aperimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Coot 6 12B-Db 0.097 n 3.36 1,50 1020 959 3219 1442 340 320 1074 481 1 D-c2ov 0.570 n 1912 15.37 61 0 1200 935 20 0 394 307 126-Obw 0,097 e 3.36 1,50 540 508 1706 764 180 169 568 254 t----G 1 D-c2ov 0.570 e 19.72 45.54 32 0 625 1442 11 0 214 493 i 2B-Obw 0.097 s 3.36 1.50 1020 927 3111 1394 340 288 966 433 i D-c2ov 0.570 s 1912 1&79 61 0 1200 1143 20 0 394 376 11jo &600 s 2076 17.58 32 32 666 564 32 32 666 564 1 2B-Ob 0.097 w 3.36 1.50 540 508 1706 764 180 169 568 254 t--G 1 D-c2ov 0570 w 19.72 4554 32 0 625 1442 11 0 214 493 C 16B-19ad 0.049 1.70 259 828 828 1404 2142 0 0 0 0 F 22A-cph 1.358 46,99 0.00 828 137 6456 0 612 104 4887 0 1 61 c)AED excursion 1 01 1 1 1 Envelope loss/gain 1 219171 120331 1 1 99451, 12 a) Infiltration 5814 1424 1938 475 b) Room ventlation 0 0 0 0 13 Internal gains Occupants @ 230 4 920 4 920 Appliances/other 3400 3400 Subtotal(linme 6 to 13) 27731, 17777 11883, 8451 Less external load 0 0 0 0 Less transfer 0 0 0 01 0 0 0 0 Redistribution 11883 8451 14 Subtotal 27731 17777 15 Duct loads 20% 401% 5506 7135 20% 40% 2359 3392 A-A Total room load 332371 249121 1 1 142421 11843, Air required(cfm) 1032 1032 4421 491 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-1905:12A9 A!%k-Pk wriightsc�ft Right-Suite@ Universal2013 13.0.01 Right J&Mobile Page I ..�wstmp\63f07abl-ece4-465a-a4el-167ec2ebOlbf.rup Cale=MJ8 Front Door faces: W Right-J@ Worksheet Job: Garrett Date: 7119/2013 am Entire House By: Tropic Heating&Air Condi Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 1 Room name Second Floor Third Floor 2 Exposed wall 128.0 It 10�0 It 80�0 ft heat/cool 3 Room height 10.0 ft heat/cool 22.0 x 18.0 It 4 Room dimensions ft2 46.0 x 18.0 ft 3%0 ft2 5 Room area 828.0 1 1 1 1 1 Ty I Construction U.v 1 0, HTM Area (w) Load Area (ft') Load I a e p) (Btuh) number (8, h1fUt2-'F)j (Bt uh/f or penmeter (ft) 'Bluh) or perimeter (ft) N/P/S Heat Cool Gross N/P/S Heat Cool 6 12B-Obw 0.097 n 3.36 1.50 460 430 1443 647 220 209 702 314 __G 1 D_. n 19.72 15.37 30 0 592 461 11 0 214 166 2ov 0,570 573 257 12B-Obw 0.097 e 336 1.50 180 168 565 253 180 171 t---G 1 D-c2o 0.570 e 19.72 4554 12 0 230 531 9 0 181 417 11 12B-Obw 0,097 s 3.36 1.50 460 430 1443 647 220 209 702 314 1 D-c2 v 0.570 s 19.72 18.79 30 0 592 564 11 0 214 204 11jo 0.600 s 20.76 17.58 0 0 0 0 0 0 0 0 2B-Obw 0.097 w 3.36 1.50 180 168 565 253 180 171 573 257 1 9 0 181 417 t--G I D-c2ov 0.570 w 19,72 45.54 12 0 230 531 C 16B-19ad 0.049 1.70 2.59 432 432 732 1118 396 396 671 1025 F 22A-cQh 1.358 46.99 000 216 33 1569 0 0 0 0 0 01 1 01 6 c)AED excursion FTEnvelope losr./gain 79611 50041 1 �401 1 33721 12 a) Infiltration 2385 584 1491 365 b) Room ventilation 0 0 13 Internal gains Occupants @ 230 0 0 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 10346 55a8. 5502 3737 Less external load 0 0 Less transfer 0 0 0 0 0 0 Redistribution 10346 5588 5502 3737 14 Subtotal 20% 40% 2054 2243 20% 40% 1092 1500 15 Duct loads - Tot I room load 124011 78311 t 1 65941 5231 Air arequired(cfm) 385 324 205 21 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-19 05:12i49 4d- wrightSC)'ft Right-.Suite@ Universal 2013 13.0.01 Right J&Mobile Page 2 ...\wstmp\63f07abl-ece4-465a-a4el-167ec2ebOlbf.rup Cale=MJ8 Front Door faces: W 16 Job: Garrett AED Assessment Date: 7/19/2013 ntire House By: Tropic Heating&Air C Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropleac@msn.com License:CAC052431 L Project Information For: Karen Garrett, Tropic Heating&AirConditioning,lnc. 123 Pine St, Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature ('F) 70 75 Elevation-, 43 ft Design TD('F) 35 16 Latitude: 30'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 8.4 52.8 Dry bulb('F) 35 91 Infiltration: Daily range('F) - 17 M V\L-tbulb('F) - 77 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 8,OOE- 7,00E_ 6,00(- 5,OOE 4,OOE- 3,OOE- 2,OOC- 1 ,OOE- 01 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Houdy Aerage AEDlirrit Maximum hourly glazing load exceeds average by 19.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Jul-19 05:12,50 + wrightSOft Right-Suite(fD Universal 2013 13.0.01 Right J@ Mobile Page 1 A__C*_1 ...\wstmp\63fD7abl-ece4-465a-a4el-167ec2ebOlbf.rup Calc=MJB FrontDoortaces: W