Loading...
221 Magnolia St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003131 Date 7/24/13 Property Address . . . . . . 221 MAGNOLIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu duct work ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ STOUT, LINDA TROPIC HEATING & AIR 221 MAGNOLIA STREET 750 MAYPORT RD ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233 (9 04) 241-1788 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/20/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph (904) 247-5826 Fax(904) 247-5845 JoB ADDRESS: L Z ;•-o�.a S�• PERMIT# PROJECT VALUE $ 0 0 ARI# 7S 7�' REQ UTRED Air Handling Equipment Only _yAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity :gr Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUYRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity r Tons Per Unit 3-.SS- Heat: Unit Quantity f BTU's Per Unit /-v�✓ Seer Rating Q D Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Cutlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: 01.2 /`MoNc'r°�c o✓� / / Zr-t��.s 6d�C--e'� - Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. ,,, // 5-p� Phone Number ��3— 7,Z/j Property Owners Name rtS �` tea. � Mechanical Company TROPIC HEATING&AIR GOND., INC. Office Phone 904-241-1788 Fax904-241-2172 Co. Address: 750 MAY-PORT ROAD City ATLANTIC BCH State FL Zip 32233 License Holder(Print): CHARLES J MARJS State is onl �egistr�ation# AC052431 Notarized Signature of License Holder KAREN E.PANTFOEDER Before me this day of 20 B _ NOTARY PUBLIC STATE OF FLORIDA Signature of Notary Public Comm#EE064448 Expires 3/4/2015 This combination qualifies for a Federal Energy D Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. livw vi.ah r i r e ctory.r Certificate of Product Ratings AHRI Certified Reference Number: 3647378 Date: 7/23/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 215BNA042"***A Indoor Unit Model Number: FV4CN(B,F)005 Manufacturer: BRYANT HEATING AND COOLING SYSTEMS Trade/Brand name: LEGACY LINE PURON HP Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING SYSTEMS Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity(Btuh): 42000 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 15.50 Heating Capacity(Btuh) @ 47 F: 42000 Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F: 25800 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahhdirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION ' The information forthe model cited on this certificate can be verified at www.ahridirectoryorg, Air-Conditioning,Heating dick on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. N-' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. Ll ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130190868165524830 Pro ect SummaJob: Stout Summary� � •� Date: 7/23/2013 Entire House By: Tropic Heating&Air C... rirww�ta iit Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicacansn.com License:CAC052431 Project • • For: Lans& Linda Stout, Tropic Heating&AirConditioning,Inc. 221 Magnolia St.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Notes: Design Information Weather: Jacksonville/Craig, FL, US Winter Design Conditions Summer Design Conditions Outside db 35 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 35 °F Design TD 16 °F Daily range M Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24553 Btuh Structure 18342 Btuh Ducts 7600 Btuh Ducts 9903 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32153 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28245 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2992 Btuh Ducts 1836 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1668 1668 Equipment latent load 4829 Btuh Volume(fta) 16680 16680 Air changes/hour 0.50 0.26 Equipment total load 33073 Btuh Equiv. AVF(cfm) 139 72 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make Trade n/a Trade Model n/a Cond AHRI ref n/a Coil AHRI ref Efficiency n/a Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1169 cfm Actual air flow 1169 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-23 14:21:17 wrightSaft Right-Suite®Universal 2013 13.0.01 Right J®Mobile Page 1 ...lwstmp\e0558885-8110-44b4-a545-6cOd87e2d82f.rup Calc=MJ8 Front Door faces: W RiRight J@ Mobile Report Job: Stout 9 p Date: 7/23/2013 Entire House By: Tropic Heating&Air C... + e> Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CAC052431 Project • • For: Lans& Linda Stout,Tropic Heating&AirConditioning,Inc. 221 Magnolia St.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M ) Method Simplified Wet buIb(°F) - 77 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh %of load Walls 3.4 8053 25.0 Glazing 31.1 5242 16.3 VIAIs D-ds Doors 13.5 433 1.3 Ceilings 1.7 1444 4.5 Floors 4.8 4098 12.7 Infiltration 2.0 5282 16.4 Ducts 7600 23.6 1r61tratcn Piping 0 0 (3a�rg 10 Humidification 0 0 � Ventilation 0 0 Call Adjustments 0 Total i 32153 100.0 • • I • Component Btuhff Btuh %of load Walls 1.5 3608 12.8 WAIS Irtand Gas Glazing 32.6 5493 19.4 Doors 11.4 367 1.3 Ceilings 2.6 2204 7.8 Floors 1.8 1516 5.4 Gating Infiltration 0.5 1294 4.6 Ducts 9903 35.1 Ventilation 0 0 Ducts Internal gains 3860 13.7 Other Blower 0 0 Ceiling; Adjustments 0 Total 28245 100.0 A ltf I ICn Latent Cooling Load=4829 Btuh Overall U-value=0.129 Btuh/ft2-°F Data entries checked. 2013-Jul-23 14:21:17 " wrightsOft Right-Suite®universal 2013 13.0.01 Right J®Mobile Page 1 ...\wstmp\eO558885-8110-44b4-a545-ScOd87e2d82f.rup Calc=MJ8 Front Door faces: W Right-J® Worksheet Job: Stout Entire House Date: 7/23/2013 aw, By: Tropic Heating&Air Condi... Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CACO52431 1 Room name Entire House First Floor 2 Exposed wM 260.0 ft 128.0 ft 3 Room height 10.0 ft d 10.0 ft heat/cool 4 Room dimensions 1.0 x 816.0 ft 5 Room area 1668.0 ft2 816.0 ft2 Ty I Construction U-value Or I HTM I Area (ft') I Load I Area (ftp) Load numbernumber (Btuh/ftl-°F) (Btuh/ft�) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 %(I___( 12B-Obw 0.097 n 3.36 1.50 900 843 2830 1268 440 413 1384 620 1Aclov 0.900 n 31.14 20.87 57 0 1765 1183 28 0 856 574 V)1 12B-Obw 0 097 e 3.36 1.50 400 373 1253 561 200 187 626 281 C, 1Ac1ov 0.900 e 31.14 53.90 27 0 830 1437 13 0 415 719 11 128-Obw 0.097 s 3.36 1.50 900 810 2717 1217 440 380 1274 571 1Aclov 0.900 s 31.14 24.62 58 0 1816 1436 28 0 882 698 11 DO 0.390 IS 13.49 11.43 32 32 433 367 32 32 433 367 12B-Obw 0.097 w 3.36 1.50 400 373 1253 561 200 187 626 281 t--(- 1Aclov 0.900 w 31.14 53.90 27 0 830 1437 13 0 415 719 C 16B-19ad 0.049 1.70 2.59 852 852 1444 2204 0 0 0 0 F 20P-5t 0.139 4.81 1.78 852 852 4098 1516 816 816 3924 1452 61 c)AED excursion 1 0 1 1 0 Envelope lossigain 1 19270 13188 1 1 10838 6279 12 a) Infiltration 5282 1294 2600 637 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 2 460 Appliances/other 3400 3400 Subtotal(lines 6 to 13) 24553 18342 13438 10776 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 24553 18342 13438 10776 15 Duct loads 31% 54% 7600 9903 31% 54% 4160 58188 Total room load I 1 1 321531 282451 I 1 1759 1 165951 1 1 Air required(cfm) 1169 1169 640 687 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-23 14:21:17 wriightsOft Right-Suite®Universal 2013 13,0.01 Right JO Mobile Page 1 ```"t ...\wstmp\e0558885-8110-44b4-a545-6icOd87e2d82f.rup Calc=MJ8 Front Door faces: W Right-J® Worksheet Job: Stout am Entire House Date: 7/23/2013 By: Tropic Heating&Air Condi... Tropic Heating &Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CACO52431 1 Room name Second Floor 2 Exposed wall 132.0 It 3 Room height 10.0 ft heat/cool 4 Room dimensions 1.0 x 852.0 ft 5 Room area 852.0 ft2 Ty Construction U-value Or I HTM I Area (ft2) I Load I Area I Load number (Btuh/ftp-°F) (BtuWftor perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 12B-Ob 0.097 n 3.36 1.50 460 431 1446 648 1A-cloy 0.900 n 31.14 20.87 29 0 908 609 V1I 12B-Obw 0.097 e 3.36 1.50 200 187 626 281 � G 1Aclov 0.900 a 31.14 53.90 13 0 415 719 11 y/ 12B-Obw 0.097 s 3.36 1.50 460 430 1443 647 ��pG 1Aclov 0.900 s 31.14 24.62 30 0 934 739 11 DO 0.390 s 13.49 11.43 0 0 0 0 12B-Obw 0.097 w 3.36 1.50 200 187 626 281 1Aclov 0.900 w 31.14 53.90 13 0 415 719 C 16B-19ad 0.049 1.70 2.59 852 852 1444 2204 F 20P-5t 0-139 4.81 1.78 36 36 173 64 6 1 c)AEC)excurs on 0 1 1 Envelope loss/gain 8433 6908 12 a) Infiltration 2682 657 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 11114 7565 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 11114 7565 15 Duct loads 31°6 54% 3440 4085 " 6501 �9 1 1148 Total room load Air required(cfm) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-23 14:21:17 Wrightsc.ft Rig ht-SuReOUniversa1201313.0.01 Right )®Mobile Page '� ...\wstmp%e0558885$110-44b4-a545-6cOd87e2d82f.rup Calc=MJ8 Front Door faces: W AED Assessment Job: Stout t t Date: 7/23/2013 Entire House By: Tropic Heating&Air C... Tropic Heating & Air Conditioning, Inc. 750 Mayport Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431 Project • • For: Lans& Linda Stout, Tropic Heating&AirConditioning,lnc. 221 Magnolia St.,Atlantic Beach, FL 32233 Phone: 904-241-1788 Fax: 904-241-2172 Email: Tropicac@msn.com Design Conditions Location: Indoor: Heating Cooling Jacksonville/Craig, FL, US Indoor temperature(°F) 70 75 Elevation: 43 ft Design TD(°F) 35 16 Latitude: 30°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 8.4 52.8 Dry bulb(°F) 35 91 Infiltration: Dailyrange(°F) - 17 ( M } Wet bulb('F) - 77 Wind speed (mph) 15.0 7.5 Test for • - • uate Exposure Diversity Hourly Glazing Load 9,00 8,00 - --_ _- ------ ___ 7,00 6,00 5,00 4,00 3,00 2,00 1 ,00 08 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day Hourly A,erage f AEDlimit Maximum hourly glazing load exceeds average by 19.8%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2013-Jul-2314:21:17 ... Wf ightsoft Right-Suite®Universal 2013 13.0.01 Right Je Mobile Page 1 ...\wstmp�e0558885-8110-44b4-a545-6cOd87e2d82f.rup Calc=MJ8 Front Door faces W