306 4th St 2013 HVAC CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
"JF7 ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003116 Date 7/22/13
Property Address . . . . . . 306 4TH ST
Tenant nbr, name . . . . . . UNIT 308
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
ROHRMAN CHARLES H TRUST DONOVAN HEATING & AIR
13074 N BIRCH BARK CT 315 SIXTH AVENUE SOUTH
JACKSONVILLE FL 32246 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 103 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/18/14
-------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 103 . 00 103 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904)247-5845
(OB ADDRESS: 30S %(�fL ST PERMIT#
PROJECT VALUE $ 4600 " ARI it 3_72:2-30 REQUIRED
Air Handling Equipment Only _LAir Handling Unit & Condenser A Condenser Only
4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity�_ Tons Per Unit 3,s, 13
Heat: Unit Quantity BTU's Per Unit 0 0 6 Seer Rating
Duct Systems: Total CFM REQUIRED
IRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
+IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace QtyAutomobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners Name e v 1QS Phone Number 90 - ZZ I—M-o
dechanical Company l A � r) Office Phone X 91-590' Fax Zy/-37ilf'
tE
;o. Address: 315 /sit City TA7Y 3c,4 State Zip 32254
jicense Holder(Print): , J J✓ 4✓Aiv State Certification/Registration#
Votarized Signature of License Holder a/
Notary Pubk No
te of Florida Before me this �Z day of �� 20 /J _
Timothy Lee Hughes'
Expires 04/03/2016 186276 Signature of Notary Public ^
c
`t
Job:
+ wrightsoft Project Summary Date: July 22,2013
Entire House BY: Aaron Thacker
Donovan Heat&Air
315 6th Ave S, Jacksonville Beach, FL 32250 Phone 904241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project
For: Charles Rohrman
308 4th St,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 99 OF
Inside db 70 OF Inside db 75 OF
Design TD 31 OF Design TD 24 OF
Daily range L
Relative humidity 50 %
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 21368 Btuh Structure 21470 Btuh
Ducts 4033 Btuh Ducts 6962 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25401 Btuh Use manufacturers data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 29569 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2616 Btuh
Fireplaces 0 Structure
Ducts 1922 Btuh
Heati ng Cooling Central vent 0 cfm) 0 Btuh
Area (ft2) 1931 1931 Equipment latent load 4538 Btuh
Volume (ft3) 15444 15444
Air changes/hour 0.38 0.20 Equipment total load 34107 Btuh
Equiv.AVF (cfm) 98 51 Req. total capacity at 0.75 SHR 3.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Payne Make Payne
Trade PAYNE Trade PAYNE
Model PH3ZNB042000AA Cond PH3ZNB042000AA
AHRI ref no3722704 Coil
AHRI ref no3722704
Efficiency 7.7 HSPF Efficiency 11.5 EER, 13.5 SEER
Heating input Sensible cooling 31125 Btuh
Heating output 41000 Btuh @ 47°F Latent cooling 10375 Btuh
Temperature rise 27 OF Total cooling 41500 Btuh
Actual air flow 1383 cfm Actual air flow 1383 cfm
Air flow factor 0.054 cfm/Btuh Air flow factor 0.049 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2013-Jul-22 09 06 00
+ wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1
,A05 C\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3.5 ton.rup Calc=MJ8 Front Door faces: E