Loading...
306 4th St 2013 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD "JF7 ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003116 Date 7/22/13 Property Address . . . . . . 306 4TH ST Tenant nbr, name . . . . . . UNIT 308 Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- ROHRMAN CHARLES H TRUST DONOVAN HEATING & AIR 13074 N BIRCH BARK CT 315 SIXTH AVENUE SOUTH JACKSONVILLE FL 32246 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/18/14 ------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)247-5845 (OB ADDRESS: 30S %(�fL ST PERMIT# PROJECT VALUE $ 4600 " ARI it 3_72:2-30 REQUIRED Air Handling Equipment Only _LAir Handling Unit & Condenser A Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity�_ Tons Per Unit 3,s, 13 Heat: Unit Quantity BTU's Per Unit 0 0 6 Seer Rating Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace QtyAutomobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name e v 1QS Phone Number 90 - ZZ I—M-o dechanical Company l A � r) Office Phone X 91-590' Fax Zy/-37ilf' tE ;o. Address: 315 /sit City TA7Y 3c,4 State Zip 32254 jicense Holder(Print): , J J✓ 4✓Aiv State Certification/Registration# Votarized Signature of License Holder a/ Notary Pubk No te of Florida Before me this �Z day of �� 20 /J _ Timothy Lee Hughes' Expires 04/03/2016 186276 Signature of Notary Public ^ c `t Job: + wrightsoft Project Summary Date: July 22,2013 Entire House BY: Aaron Thacker Donovan Heat&Air 315 6th Ave S, Jacksonville Beach, FL 32250 Phone 904241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project For: Charles Rohrman 308 4th St,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 99 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 24 OF Daily range L Relative humidity 50 % Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 21368 Btuh Structure 21470 Btuh Ducts 4033 Btuh Ducts 6962 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25401 Btuh Use manufacturers data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 29569 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2616 Btuh Fireplaces 0 Structure Ducts 1922 Btuh Heati ng Cooling Central vent 0 cfm) 0 Btuh Area (ft2) 1931 1931 Equipment latent load 4538 Btuh Volume (ft3) 15444 15444 Air changes/hour 0.38 0.20 Equipment total load 34107 Btuh Equiv.AVF (cfm) 98 51 Req. total capacity at 0.75 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Payne Make Payne Trade PAYNE Trade PAYNE Model PH3ZNB042000AA Cond PH3ZNB042000AA AHRI ref no3722704 Coil AHRI ref no3722704 Efficiency 7.7 HSPF Efficiency 11.5 EER, 13.5 SEER Heating input Sensible cooling 31125 Btuh Heating output 41000 Btuh @ 47°F Latent cooling 10375 Btuh Temperature rise 27 OF Total cooling 41500 Btuh Actual air flow 1383 cfm Actual air flow 1383 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2013-Jul-22 09 06 00 + wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1 ,A05 C\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3.5 ton.rup Calc=MJ8 Front Door faces: E