82 W 8th St 2013 HVAC CITY OF ATLANTIC BEACH 111 j 800 SEMINOLE ROAD J _ ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 'vJF !SA Application Number . . . . . 13-00003101 Date 7/22/13 Property Address . . . . . . 82 W 8TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ELO ANN MARIE TRUST DONOVAN HEATING & AIR C/O ANN MARIE WILLIAMSON 315 SIXTH AVENUE SOUTH 8483 BERESFORD LANE JACKSONVILLE BEACH FL 32250 JACKSONVILLE FL 32244 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . 2 TON Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/18/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 --------------------- Fee summary Charged Paid Credited ----Due--- ----------------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904)247-5845 IoB ADDRESS: g��- V��Sr 8 1�- sfi PERMrr# PROJECT VALUE $ 31 q4 ARI# 5 7 Z5540 REQUIRED Air Handling Equipment Only f Air Handling Unit & Condenser Condenser Only STEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 2- Heat: Unit Quantity T— BTU's Per Unit ZY o0v Seer Rating i3 Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) +IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read lis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to vio'l'ate/the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name A rJ-) Wi I I, Phone Number 301~ '7137 Mechanical Company. _�1 )nrJ vyp►J W EAT e Arrz Office Phone ZV1370- Fax ZV/3_7X1 ;o. Address: 315 G t� ryE 5 City ��+r 13 State F1 Zip 3Z2<t;' ,icense Holder(Print): vV.i bA,,- -H__ State Certification/Registration# (,A co 397 j Notarized Signature of License Holder IoW" Notary Public state or Florida efore me s 9 day of .l�-� 20 j3 Timothy Lee Hughes x Commission 16 188278 1 ature of No Public OF ti Expires 04/0312018 . 9 Project Summary Job: wri htsoft � Summary Date: 7/19/13 Entire House By: Brandon Zaharie Donovan Heat&Air 315 6th ave south, Jacksonville Beach, FL 32250 Phone. 241-3785 Email brandon@donovanac com For: Williamson 82 West 8th St,Atlantic Beach, FL 32233 Notes: Design Iriformati6if Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 68 °F Inside db 75 °F Design TD 29 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 13919 Btuh Structure 11729 Btuh Ducts 2799 Btuh Ducts 5690 Btuh Central vent (12 cfm) 370 Btuh Central vent(12 cfm) 255 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 17088 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1638 Btuh Ducts 973 Btuh Heating Cooling Central vent (12 cfm) 420 Btuh Area (ft') 1152 1152 Equipment latent load 3031 Btuh Volume (ft') 10368 10368 Air changes/hour 0.57 0.23 Equipment total load 20706 Btuh Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Makeennox Make Lennox Trade Trade Model 13HPX-024 Cond 13HPX-024 ARI ref no. 725540 Coil CBX25UH-024 ARI ref no. 5725540 Efficiency 8 HSPF Efficiency 13 SEER Heating input Sensible cooling 15747 Btuh Heating output 22384 Btuh @ 47°F Latent cooling 6749 Btuh Temperature rise 27 °F Total cooling 22496 Btuh Actual air flow 750 cfm Actual air flow 750 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. -+#-t- wvightsoft Right-Suite®Universal 7.1.01 RSU05996 2013-Jul-19 10 32:45 �' C:\Users\Sales\Documents\Wrightsoft HVAC\2Tonrup Calc=MJ8 Orientation=N Page 1