Loading...
1213 Jasmine St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003156 Date 7/29/13 Property Address . . . . . . 1213 JASMINE ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ FRICK PATRICIA ANN DONOVAN HEATING & AIR 1213 JASMINE ST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322331818 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . - Permit Fee . . . . 87 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/25/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 IoB ADDRESS: 12-12) '3 0 S n")Tyye !�5r PERmrr# PROJECT VALUE $ ARI# —REQUIRED Air Handling Equipment Only _��Air Handling Unit & Condenser Condenser Only 4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit I.S Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED ?IRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) ?IRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name 6,s L le-, 0K6E1FC Phone Number o 2— Aechanical Company Office Phone 2q( Vg-Fax 2 q 13-7(4S— I city --- - State F1 ZiD32ZSV lo. Address: �s JAX 2 'icense Holder(Print): ye, State Certification/Registration# Votarized Signature of License Holder -&�i2 4 dda BeforemelVi-, 7-1 dayof 1� 20 /3 Notary PUbliC State of Flo 01 N *, jjg T Timothy Lee Hughes - ee My Commission EE 186278 Signature of Notary Public 4 01 Expires,OX4/03/2016 Job: wrightsoft Project Summary Date: 7/26/13 Entire House By: Brandon Zaharie Donovan Heat&Air 315 6th ave south, Jacksonville Beach, FL 32250 Phone 241-3785 Email.brandon@donovanac.com Project Information For: Okeefe 1213 Jasmine ST,Atlantic beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9277 Btuh Structure 10200 Btuh Ducts 1227 Btuh Ducts 1383 Btuh Central vent(28 cfm) 894 Btuh Central vent (28 cfm) 617 Btuh Humidification 0 Btuh Blower 0 Btuh pipigg 0 Btuh Equipment load 11397 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12200 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1434 Btuh Ducts 293 Btuh Heati n Coolin Central vent (28 cfm) 1015 Btuh Area (ft2) 480 480 Equipment latent load 2741 Btuh Volume (ft3) 4320 4320 14941 Btuh Air changes/hour 0.89 0.32 Equipment total load 1.5 ton Equiv.AVF (cfm) 64 23 Req. total capacity at 0.70 SHR Heating Equipment Summary Cooling Equipment Summary Make carrier Make carrier Trade Trade Model 25HBC518 Cond 25HBC518 ARI ref no. 5950184 Coil F64CNP018 ARI ref no. 5950184 Efficiency 8 HSPF Efficiency 14 SEER Heating input Sensible cooling 10779 Btuh Heating output 15323 Btuh @ 47'F Latent cooling 4620 Btuh Temperature rise 27 OF Total cooling 15399 Btuh Actual air flow 513 cfm Actual air flow 513 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.82 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. AL. Right-SuiteOD Universal 7 1,01 RSU05996 2013-Jul-26 14:34.43 Page I AC(5K C:\L)sers\Sales\Documents\Wrightsoft HVAC\1 5 TON rup Calc=MJ8 Orientation=N