Loading...
444 Osprey Key 2013 HVAC CITY OF ATLANTIC BEACH. 800 SEMINOLE ROAD r� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 J!tit � Application Number . . . . . 13-00003164 Date 7/30/13 Property Address . . . . . . 444 OSPREY KEY Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ------------------------------------------------------------------ Application desc 1 cu 1 ahu 3 tons ------------------------------------------------------------------ Owner Contractor ------------------------ -------------- WHEELER, JACK D. WHITLEYS HEATING AND AIR LLC 444 OSPREY KEY 6299-16 POWERS AVE ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32217 ------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/26/14 ----------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------ Fee summary Charged Paid Credited Due ----------------- ---------- ---------- --------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: y� SSP rLy PERMIT# PROJECT VALUE S 2000 " ARI# 3 6 S O 41, 9'S REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3 Heat: Unit Quantity_ I BTU's Per Unit 36", 000 Seer Rating Duct Systems: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name )a(A o k`e e4-c& Phone Number 2 q4 " 951 Q Mechanical Company c f Let< 5 1 Office Phone 33Y3 Sit Fax SIC Co. Address: wt/14 City 4cVk5op V;I tC State j�—' Zip �7 License Holder (Print): �1 State Certification/Registration#C/>Ec/8`/4 41y! Notarized Si older ,�ui'�" �+ SHIRLEY L GRA 2O *' t `AYCOMMISSIONkDD�re e this of IL EXPIRES:February 14,2014 ' p;h Bonded Th. otayPublic e of Notary Public www.ceproposals.com/loadcalculator http://www.acquickquote.com/load/ Summary Load Calculations Wheeler 444 osprey key atlantic beach Florida Summer Infiltration for the ENTIRE House 1. Air Changes per hour(.30 RNC or .50 for AOR) = 0.5 AC/HR 1200 X 9 10800 Cu. Ft. SQ FT Ceiling Hgt 3. Total Infiltration= 0.5 X 10800 Cu.Ft X 0.0167 = 90 CFM Summer Infiltration 1. Design Temperature Difference= Summer Design- Room Temperature = 20 °F 90 CFM 2. Total Infiltration = 3. Sensible Gain 1984 Btuh Latent Infiltration Gain for the Entire House 1. Grains of Moisture Difference from Table 1 = 60 grains 2. Total Infiltration = 90 CFM 3. Total Infiltration Load = 3679 Equipment Sizing Calculation (Two People Per Bedroom) Number of Bedrooms 4 Number of Applicances 3 Latent Load for Appliances and People = 5440 People Latent Infiltatrion Load = 3679 Latent Equipment Sizing Load = 9119 Btuh Heating Summary Design Heating Load Requirements = 15960 Btuh (Total Heat Loss for Entire House) Cooling Summary Total Sensible Gain 22410 Btuh Total Latent Gain 9119 Btuh Total Btuh(required) = Sensible + Latent or 31530 Btuh Minimum Total Cooling Tonnage 2.6 Allowable 25% increase 3.3 Based on ACCA Manual J Calculations Square Feet Per Ton 457 7/30/2013 9:28 AM loft