444 Osprey Key 2013 HVAC CITY OF ATLANTIC BEACH.
800 SEMINOLE ROAD
r� ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
J!tit �
Application Number . . . . . 13-00003164 Date 7/30/13
Property Address . . . . . . 444 OSPREY KEY
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
------------------------------------------------------------------
Application desc
1 cu 1 ahu 3 tons
------------------------------------------------------------------
Owner Contractor
------------------------
--------------
WHEELER, JACK D. WHITLEYS HEATING AND AIR LLC
444 OSPREY KEY 6299-16 POWERS AVE
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32217
-------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/26/14
-----------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: y� SSP rLy PERMIT#
PROJECT VALUE S 2000 " ARI# 3 6 S O 41, 9'S REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit 3
Heat: Unit Quantity_ I BTU's Per Unit 36", 000 Seer Rating
Duct Systems: Total CFM REQUIRED
Manual J documentation required on residential change out
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name )a(A o k`e e4-c& Phone Number 2 q4 " 951 Q
Mechanical Company c f Let< 5 1 Office Phone 33Y3 Sit Fax SIC
Co. Address: wt/14 City 4cVk5op V;I tC State j�—' Zip �7
License Holder (Print): �1 State Certification/Registration#C/>Ec/8`/4 41y!
Notarized Si older
,�ui'�" �+ SHIRLEY L GRA 2O
*' t `AYCOMMISSIONkDD�re e this of
IL
EXPIRES:February 14,2014
' p;h Bonded Th. otayPublic e of Notary Public
www.ceproposals.com/loadcalculator http://www.acquickquote.com/load/
Summary Load Calculations
Wheeler 444 osprey key atlantic beach Florida
Summer Infiltration for the ENTIRE
House
1. Air Changes per hour(.30 RNC or .50 for AOR) = 0.5 AC/HR
1200 X 9 10800 Cu. Ft.
SQ FT Ceiling Hgt
3. Total Infiltration= 0.5 X 10800 Cu.Ft X 0.0167 = 90 CFM
Summer Infiltration
1. Design Temperature Difference= Summer Design- Room Temperature = 20 °F
90 CFM
2. Total Infiltration =
3. Sensible Gain 1984 Btuh
Latent Infiltration Gain for the Entire House
1. Grains of Moisture Difference from Table 1 = 60 grains
2. Total Infiltration = 90 CFM
3. Total Infiltration Load = 3679
Equipment Sizing Calculation
(Two People Per Bedroom) Number of Bedrooms 4
Number of Applicances 3
Latent Load for Appliances and People = 5440 People
Latent Infiltatrion
Load
= 3679
Latent Equipment Sizing Load = 9119 Btuh
Heating Summary
Design Heating Load Requirements = 15960 Btuh
(Total Heat Loss for Entire House)
Cooling Summary
Total Sensible Gain 22410 Btuh
Total Latent Gain 9119 Btuh
Total Btuh(required) = Sensible + Latent or 31530 Btuh
Minimum Total Cooling Tonnage 2.6
Allowable 25% increase 3.3
Based on ACCA Manual J Calculations Square Feet Per Ton 457
7/30/2013 9:28 AM
loft