1245 Jasmine St HVAC 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Application Number . . . . . 13-00003175 Date 8/02/13
Property Address . . . . . . 1245 JASMINE ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 3 ton
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
ROCKWELL JULIA M TROPIC AIRE OF NORTH FLORIDA
54005 TURNING LEAF DR 9969 OLD KINGS ROAD
CALLAHAN FL 32011 JACKSONVILLE FL 32219
(904) 713-9600
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . 8/01/13 Valuation . . . . 0
Expiration Date . . 1/28/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
------------ ----------------------------------------------------------------
Fee summary Charged Paid Credited Due
------- ---------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
Jul 31 13 11:24a E 00ft 904-7654545 P.1
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
goo Seminole Rd Atlantic Beacb, FL 32233
Ph(904) 247-5826 Fax (904)247-5845
JoB Aimmss: IP(4,E� nRMT#
-'7C
PROJECT VALIVE $_20_*1_ AR14 3 ) 51C):�
REQUIRED
NEW AM CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons PerUnit Seer Ratin
Heat: Unit Quantity BTUs Per Unit REQUIRED
Duct Systems: Total CFM.
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ,
Air Conditioning: Unit Quantity Tons Per Unit 3 1 1�;.10 10
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE
Fire Sp er Syst Quantity (Requires 3 sets of plans)
Fire Standpipe q Quantity (Requires 3 sets of plans)
Underground Fire]qain Value (Requires 3 sets of plans)
Fire Hose Cabinet< Quantity (Requires 3 sets of plans)
Commercial Hoocls, Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Require Is 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Firer�lace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevaton/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlet-, Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
9 Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
oned for six months.I hercbY certify that I have read
Permit becomes void ifwork does not commence ivitbin a six mon period or work is suspended or aband
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with wlether specified
or noL Mw pamit does not gizve auihority to violate ft provisions of any other state or local law rcgWation construction or the petformance of construction.
Property Owners Nam(, Phone Number .1, S
-FL- office Phortel 13'%00 Fa�
Mechanical Comp 0S-14 SG4
a.Ad&ess: 99 On�� 6 Cit)" �_A y State zip 3D-._)1C1
License Holder(Print): —State Certification/Registration# 0\0 OSl 31P 61
Notarized Signature qjFLicense Holder
Sworn and s �bedfbre me this of 201-3—
lot
17.1t WEA" .01fErT
IEEMM 0 0 ry P
WCOM Ire
V.: EXPIMA 27,2M4 Signature o otary Public "tLt�M_S��
MhwN unurm1ws
Aug 02 13 03:32p Soott 904-765-4545 P.1
DesignStar Load Calculation4l
Resufts are intended for use with Rheem heating and cooling systems
Customer Information
Street Add ress, 124 5 j as m i n e St, Ad a nti c Beach, F L 32233
------------
Latitude, Longitude 30.33750, -81.76860
.................... ...........
House Square Footage: 1470 sq. ft.
...... -------------- ------- -----------
Name: Jaime Mull ins/Rockwel I
Phone:
.......... ........... ...... ------------ -------------------
Email:
............ ---------------
House Information
SHR .75
........................ -------
Number of residents 2
............ .........
Ceiling height 9
------------ .........
Wall U-value R-value 0.09 1 11
.................
Floor U-value R-value 0,2 15
----------
Ceiling U-va ue j R-value 0.053 1 19
..................... ... .......................
Window U-value 0.5
.....................
Window SHGF 0.85
............... .......................... ........... ......
Moisture grains 53
..................... ..........
Duct I oss % 10
Duct gain % 10
........... ....... ---------
Cooling infiltraction (ACH) 0.6
................
Heating infiltration (ACH) 0.8
Winter venti ation 0
----------- ...........-.1---------- ............. ......................----------
Summer vertilation 0
.......... ....... ...................
Aug 02 13 03:33p Smtt 904-765-4545 p.2
iDesiqn Conditions
Outdoor Heating Cooling
Dry bulb ff 32 93
...................
Daily range M
.............. ............ ............ .......
Relative humidity 50%
,................. ............ ................
Moisture difference 53
---------- ............... ........
Heating Cooling
Indoor temperature (OF) 70 75
--_------------ .......
Design temperature difference(*F) 38 18
Aug 02 13 03:33pp.3
'
Heatincl Loads
Area Btuh % of load
Wall 3995 14.3
Floor 7524 27
Ceiling 2962 10.6
Windows 4028 14.4
System Efficiency Loss 2537 9.1
Total: 27902
Heating Loads
27-902 BTU11--i
Systern Efficiency Loss
Floor
-I-Ceiling
Wall-
! '
Infiltration-- - `Windows
`
�
Aug 02 13 03:33p S Mtt 904-765-4545 p.4
;Coolinq Loads
Area Btuh % of load
Wall 2944 9.3
............
Ceiling 4129 13
Windows 11789 37.2
--------------
Sensible Infiltration 2436 7.7
Latent I nfiltrati on 4434 14
................
System Efficiency Gain 2573 8.1
...........I.-
Internal 2499 7.9
Sensible People Load 460 1.4
Latent People Load 460 1.4
Total: 31725
Sensible load 26830
Latent load 4894
----------
SHR 0.85
----------
Capacity at .75 SHR 2.98 Tons
.............
Cooling Loads
3,1,7 2 BTL4 11 r
5ens ible People Load
Latent People Load
Sensible Infiltration
Inbernal
Windows
Systern Efficienc)
Wall
Ceiling
Latent Infiltration
Aug 02 13 03:34p soott 904-765-4545 P.5
Adequate Exposure Diversity
AED Graph
15000
lucc)
5 0 0
3am ga-n- 10--ni 11arn 12pm 1PM 2prn 3pm 4pm 5PM 6pm 7pm 80M
Hourly Loads Average
EqUiPMEmt selection
Svstem equipment selec:on w It be rrade using the Mlowing darived values.
Glass (E) 107 sq. ft.
---------------
Glass (S) 15 sq. ft.
Glass (N) '15 sq. ft.
Glass M 75 sq, ft.
.................... ............
Summer Outdoor 93"F
Summer Wet Bulb 770F
..................
Summer Indoor 750F
.............
Summer Design Grains 50%
Winter Outdoor 320F
Winter Indoor 70OF
Sensible Cooling 26,830 Btuh
---------------------- ------- ......
Latent Cool i ng 4,894 Btuh
................--.-............
Required Cooling Airflow 1,220 CFM
-----------------............................... ..........
Sensible Heating 27,902 Btuh
.......... ---------............... ......
Required H-eating Airflow 362 CFM
................
All CakUlations are L)ased-j.aon approved hvac a)dUStTY standards and procedules,and comply with all local,
state ard federal ccoe requirementF-Ali computed reSLAS are Estirnates,Prc&ct provided by Energy Design
Systems and Idea 7ree