1245 Jasmine St HVAC 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 Application Number . . . . . 13-00003175 Date 8/02/13 Property Address . . . . . . 1245 JASMINE ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 3 ton ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ ROCKWELL JULIA M TROPIC AIRE OF NORTH FLORIDA 54005 TURNING LEAF DR 9969 OLD KINGS ROAD CALLAHAN FL 32011 JACKSONVILLE FL 32219 (904) 713-9600 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . 8/01/13 Valuation . . . . 0 Expiration Date . . 1/28/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------ ---------------------------------------------------------------- Fee summary Charged Paid Credited Due ------- ---------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Jul 31 13 11:24a E 00ft 904-7654545 P.1 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH goo Seminole Rd Atlantic Beacb, FL 32233 Ph(904) 247-5826 Fax (904)247-5845 JoB Aimmss: IP(4,E� nRMT# -'7C PROJECT VALIVE $_20_*1_ AR14 3 ) 51C):� REQUIRED NEW AM CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons PerUnit Seer Ratin Heat: Unit Quantity BTUs Per Unit REQUIRED Duct Systems: Total CFM. REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION , Air Conditioning: Unit Quantity Tons Per Unit 3 1 1�;.10 10 Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE Fire Sp er Syst Quantity (Requires 3 sets of plans) Fire Standpipe q Quantity (Requires 3 sets of plans) Underground Fire]qain Value (Requires 3 sets of plans) Fire Hose Cabinet< Quantity (Requires 3 sets of plans) Commercial Hoocls, Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Require Is 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Firer�lace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevaton/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlet-, Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's 9 Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: oned for six months.I hercbY certify that I have read Permit becomes void ifwork does not commence ivitbin a six mon period or work is suspended or aband this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with wlether specified or noL Mw pamit does not gizve auihority to violate ft provisions of any other state or local law rcgWation construction or the petformance of construction. Property Owners Nam(, Phone Number .1, S -FL- office Phortel 13'%00 Fa� Mechanical Comp 0S-14 SG4 a.Ad&ess: 99 On�� 6 Cit)" �_A y State zip 3D-._)1C1 License Holder(Print): —State Certification/Registration# 0\0 OSl 31P 61 Notarized Signature qjFLicense Holder Sworn and s �bedfbre me this of 201-3— lot 17.1t WEA" .01fErT IEEMM 0 0 ry P WCOM Ire V.: EXPIMA 27,2M4 Signature o otary Public "tLt�M_S�� MhwN unurm1ws Aug 02 13 03:32p Soott 904-765-4545 P.1 DesignStar Load Calculation4l Resufts are intended for use with Rheem heating and cooling systems Customer Information Street Add ress, 124 5 j as m i n e St, Ad a nti c Beach, F L 32233 ------------ Latitude, Longitude 30.33750, -81.76860 .................... ........... House Square Footage: 1470 sq. ft. ...... -------------- ------- ----------- Name: Jaime Mull ins/Rockwel I Phone: .......... ........... ...... ------------ ------------------- Email: ............ --------------- House Information SHR .75 ........................ ------- Number of residents 2 ............ ......... Ceiling height 9 ------------ ......... Wall U-value R-value 0.09 1 11 ................. Floor U-value R-value 0,2 15 ---------- Ceiling U-va ue j R-value 0.053 1 19 ..................... ... ....................... Window U-value 0.5 ..................... Window SHGF 0.85 ............... .......................... ........... ...... Moisture grains 53 ..................... .......... Duct I oss % 10 Duct gain % 10 ........... ....... --------- Cooling infiltraction (ACH) 0.6 ................ Heating infiltration (ACH) 0.8 Winter venti ation 0 ----------- ...........-.1---------- ............. ......................---------- Summer vertilation 0 .......... ....... ................... Aug 02 13 03:33p Smtt 904-765-4545 p.2 iDesiqn Conditions Outdoor Heating Cooling Dry bulb ff 32 93 ................... Daily range M .............. ............ ............ ....... Relative humidity 50% ­­,................. ............ ................ Moisture difference 53 ---------- ............... ........ Heating Cooling Indoor temperature (OF) 70 75 --_------------ ....... Design temperature difference(*F) 38 18 Aug 02 13 03:33pp.3 ' Heatincl Loads Area Btuh % of load Wall 3995 14.3 Floor 7524 27 Ceiling 2962 10.6 Windows 4028 14.4 System Efficiency Loss 2537 9.1 Total: 27902 Heating Loads 27-902 BTU11--i Systern Efficiency Loss Floor -I-Ceiling Wall- ! ' Infiltration-- - `Windows ` � Aug 02 13 03:33p S Mtt 904-765-4545 p.4 ;Coolinq Loads Area Btuh % of load Wall 2944 9.3 ............ Ceiling 4129 13 Windows 11789 37.2 -------------- Sensible Infiltration 2436 7.7 Latent I nfiltrati on 4434 14 ................ System Efficiency Gain 2573 8.1 ...........I.- Internal 2499 7.9 Sensible People Load 460 1.4 Latent People Load 460 1.4 Total: 31725 Sensible load 26830 Latent load 4894 ---------- SHR 0.85 ---------- Capacity at .75 SHR 2.98 Tons ............. Cooling Loads 3,1,7 2 BTL4 11 r 5ens ible People Load Latent People Load Sensible Infiltration Inbernal Windows Systern Efficienc) Wall Ceiling Latent Infiltration Aug 02 13 03:34p soott 904-765-4545 P.5 Adequate Exposure Diversity AED Graph 15000 lucc) 5 0 0 3am ga-n- 10--ni 11arn 12pm 1PM 2prn 3pm 4pm 5PM 6pm 7pm 80M Hourly Loads Average EqUiPMEmt selection Svstem equipment selec:on w It be rrade using the Mlowing darived values. Glass (E) 107 sq. ft. --------------- Glass (S) 15 sq. ft. Glass (N) '15 sq. ft. Glass M 75 sq, ft. .................... ............ Summer Outdoor 93"F Summer Wet Bulb 770F .................. Summer Indoor 750F ............. Summer Design Grains 50% Winter Outdoor 320F Winter Indoor 70OF Sensible Cooling 26,830 Btuh ---------------------- ------- ...... Latent Cool i ng 4,894 Btuh ................--.-............ Required Cooling Airflow 1,220 CFM -----------------............................... .......... Sensible Heating 27,902 Btuh .......... ---------............... ...... Required H-eating Airflow 362 CFM ................ All CakUlations are L)ased-j.aon approved hvac a)dUStTY standards and procedules,and comply with all local, state ard federal ccoe requirementF-Ali computed reSLAS are Estirnates,Prc&ct provided by Energy Design Systems and Idea 7ree