Loading...
196 Seminole Rd HVAC 2013 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 Application Number . . . . . 13-00003184 Date 8/02/13 Property Address . . . . . . 196 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 2 . 5 TONS ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KRITSKY ERIC M SNYDER HEATING & AIR 196 SEMINOLE ROAD P.O. BOX 16826 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32245 (904) 325-9979 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/29/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 '011 ADDRESS: I 9ip Sc-vv%x%-4Q%..E '�J PERMIT# ARI# 5 1 q j 10 7 PROJECTVALUE$ 'i,-61410200 —REQUIRED —Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only iEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Ratin2 Duct Systems: Total CFM REQUIRED CEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit I d�l Heat: Unit Quantity BTU's Per Unit Seer Rating_ Duct Systems: Total CFM REQUIRED PIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) 4RE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Reffigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or z)t. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name Ek;z_ 14rf,41.9% kv Phone Number to/Z- 191/ '-7 4echanical Company Office Phone &q/-o(pooFax_t&!f�z ?-� .o. Address: P- 0. 13*.)< Ci jt*� State f-1- Zip 52:LL/5- ,icense Holder(Print): S Certification/Registration# 64ONW3- i6tarized Signature ofLicense Holder HULY&FOUST Before me this z� day of aLZAA 20 122 My COMMISSION#EE MW U EXPIRES:July 21,2016 Signature of Notary Public t"I'de BaN Thru Budget Notoy Sw4m �R —1 DesignStar Load Calculation Results are intended f6r use with Rheern heating and cooling systenis Tne Ne*DeTeeof Comlor Customer Information J Street Address 196 seminole rd, Atlantic Beach, FL 32233 ..................--.................--............ ................- ............................-................- -- --.-.......... .....................- ............... Latitude, Longitude 30.33750, -81.76860 ...........................................................................- ..........-.................................................. .............................. ............ ...............--............ House Square Footage: 1324 sq. ft. ........... ..................... r............... ........... .................-................ .......... ...............- ............ .......... Name: eric kritsky ............- ....................... ........... .......- Phone: 123-123-1234 I....................I............................... .............. ........... ......................-..........- .............. Email: exampie@mail.com ........................ House Information SHR .75 ............ ............. Number of residents 2 1 1 11 11 -. I............ Ceiling height 9 -.1. 1 11 -I� - .......... Wall U-value I R-value 0.09111 Floor U-value R-value 0.2 15 Ceiling U-value I R-value 0.0531 19 Window U-value 0.5 .......... .............. .. .. .. .... ................ .... .. ......... Window SHGF 0.85 Moisture grains 53 1.1-1-....................... Ductloss % 10 Duct gain % 10 ............ ...... Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter ventilation 0 1--1.�1. ---I.............. ............. Summer ventilation 0 �iDesign Conditions Outdoor Heating Cooling ............ .......... Dry bulb (OF) 32 93 Daily range M Relative humidity 50% Moisture difference 53 Indoor Heating Cooling ............... .......... .......... .......... Indoor temperature (OF) 70 75 .............. Design temperature differenceff) 38 18 Heating Loads Area Btuh % of load ...............I............1-111.1--.1.1...............- ................................... Wall 3834 15.4 .......... Floor 6338 25.5 Ceiling 2667 10.7 .............................- ............. ................ ..- --.1.11 1...........-.111, .--...1-1-1. Windows 3591 14.4 ................................................... ................... ................. Infiltration 6176 24.8 1--,-.................- ..............-1-1-1.1� 1111-.......... System Efficiency Loss 2261 9.1 -............... .......... ............................. .1-1--........... Tota 1: 24866 ............................ ............- Heabng Loads 24,866 BTU/hr S"m Efficiency Loss Floo Ceiling Windows Infiltration Wall cooling Loads ----------- Area Stuh % of load ..................I..............................1......................-......................-................-........................ ............ Wall 2825 9.8 ....................................... ....................................................................................................................... Ceiling 3719 12.9 ..........-1-1 1....................-1-1.1--,.......... .......... .................. Windows 10530 36.6 ................. I..................................................... ........................-.1 - - ...........-- .................. Sensible Infiltration 2194 7.6 I.......... .111.1 ............................................. ...............-.........11-111.--.............-.I.,.,,.,.., I - Latent Infiltration 3994 13.9 ...............................- ..................................-......................................- ....................... System Efficiency Gain 2326 8.1 .................. ...................................--.-............................. Internal 2251 7.8 ...................................... ......................................I................................... ..............I........................ Sensible People Load 460 1.6 ...................I..................-.1-1.1-----............. .............---........................... Latent People Load 460 1.6 I.................................. .............................I.................. ............ ............ Total: 28758 ..................................................................... ..........................-........................................................................... Sensible load 24305 -1111.1.1........... 11.11............... ...........................I............--- - .......... ...... Latent I oad 4454 .....................I......................................................-............................. SHR 0.85 -.11,............... ........... .......................... ............. Capacity at .75 SHR 2.70 Tons .................... .....................-I .-I--, I............ .......................... Cooling Loads 28,758 BTU/hr Sensible People Load Latent People Load Sensible Infiltration Internal Windows IA'agn,System Efficiencl wall Latent Infiltration Ceiling Adequate Exposure Diversity AED Graph 15000 10000 0 5000 0 8am 9arn 10am 11arn 12pm 1PM 2pm 3pm 4prn 5PM 6pm 7pm 8pm Hourly Loads Average Equipment selection System equipment selection will be made using the following derived values. Glass (E) 96 sq. ft. ............... Glass (S) 13 sq. ft. .............- Glass (N) 13 sq. ft. -.11 11.11.1 -....................... ............... .......... Glass (W) 67 sq. ft. ............. Summer Outdoor 930F I-� -.......................1 11.11 11........"I'll I�I---............. ........... ......................- Summer Wet Bulb 770F ................... Summer Indoor 750F ................ ..................... Summer Design Grains 50% ........... ........................ ..................... Winter Outdoor 320F 111 1.-...............-.1-1.1--............... ........... ..........-................- ................... Winter Indoor 70OF .............. Sensible Cooling 24,305 Btuh I........... --........... ................... ............... ..................11...................... ........................- Latent Cooling 4,454 Btuh I.......................................--............ ................ Required Cooling Airflow 1,105 CFM ................-............... ............ ................................................... ......................... Sensible Heating 24,866 Btuh ..............I..........".." --.-.............-1.......................-........... ............ Required Heating Airflow 323 CFM ...............11 1............. ....................... ............. All calculations are based upon approved hvac industry standards and procedures,and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Design Systems and Idea Tree CERTIFIED-, Certificate of Product Ratings AHRI Certified Reference Number: 5919027 Date: 8/2/2013 Product:Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number:4TWR3030CI Indoor Unit Model Number:TEM3AOB3OS31+TDR Manufacturer:TRANE Trade/Brand name:XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(13tuh): 29000 EER Rating(Cooling): 11.50 SEER Rating(Cooling): 13.25 Heating Capacity(Btuh)@ 47 F: 29000 Region IV HSPF Rating (Heating): 8.00 Heating Capacity(Btuh)@ 17 F: 16700 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary re(ate. DISCLAIMER AHRI does not endorse the product(s)[Wed on this Certificate and makes no representations,warranties or guarantees as to,and assurnes no responsibility for, theproduct(s)" I on this Certificate.AHRI expressly discialms am liability for damages of any kind arising out of the use or performance ofthe product(s),or the unauthorized alteration of date listed on this Certificate.Certified ratings we valld ordy for and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and Its contents am proprietary products ofAHRL This Certificate shall only be used for indWMuak personal and confidential reference purposes. The contents of this Certificate may not In whole or in part,be reproduced;copied;di � kmftd;entered kft a compular database;or otherwise utilhad,In any form or mannor or by any means,except for the usees individuak personal and confidential reference. CERTIFICATE VERIFICATION The i for., for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify CerdficatL"Ink and enter the AHN Certified Reference Number and the date on On ILI and Refrigeration institute which the certificate was Issued,which Is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130199201012696670