Loading...
1554 Linkside Dr 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 Application Number . . . . . 13-00003181 Date 8/01/13 Property Address . . . . . . 1554 LINKSIDE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2 . 5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ VESOTSFI, JOHN L. SNYDER HEATING & AIR 1554 LINKSIDE DRIVE P.O. BOX 16826 ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32245 (904) 325-9979 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Eate . . . . Valuation . . . . 0 Expiration Date . . 1/28/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVE) ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax (904)247-5845 OB ADDRESS: t Sl;'Ii PERmyr# PROJECTVALUE$ 5t%0-00 ARI# 19 9 _REQUIRED —Air Handling Equlipment Only _y Air Handling Unit & Condenser Condenser Only CEW AIR CONDITIONING & HEATING SYSTEM ]INSTALLATION Air Conditioning: Jnit Quantity Tons Per Unit - Heat: Jnit Quantity BTU's Per Unit Seer Rating Duct Systems: rotai CFM REQUIRED tEPLACEMENT A IR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Jnit Quantity Tons Per Unit -L .'G7 Heat: Unit Quantity i BTU's Per Unit Seer Rating--LS Duct Systems: Total CFM REQUIRED 4RE PREVENTIO Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) 4RE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators �LL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work doe! . not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read ds application and know the sarr e to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or at. The permit does not give aut iority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name 'S QV,^ Phone Number m i- 5:6�-4 4echanical Company S^411� CQ- Office Phone ka4\-,o\.offax 'o. Address: ��14Q /,/ city 7& -2c State �L_ Zip -:�7vLq 5- ,icense Holder(Print): A State Certification/Registration# V -V �otarized Signature of License Holder E_c�L'i i, HOLLY A.FOI JST Before me this, f)) S+ day of QTJAI-xl 20 1--S MY COMMISSION#I E 204656 0 EXPIRES:Ju�2 204 SiLmoiture of Notary Pwblic 7de WM Tbru BudgO W ry Smm Z�. AHRI Certifiec Reference Number: 5919027 Date: 7/31/2013 Product:Split 1.1 ystem: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit M el Number:4TWR3030CI Indoor Unit Moc lei Number:TEM3AOB3OS31+TDR Manufacturer:I RANE Trade/Brand nane:XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 29000 EER Rating(Cooling): 11.50 SEER Rating(Cooling): 13.25 Heating Capacity(Btuh) 47 F: 29000 Region IV HSPF Rating(Heating): 8.00 Heating Capacity(Btuh) 17 F: 16700 Ratings followed by an aslerisk indicate a voluntary rerate of previously published data,unless accornpanied with a WAS.which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse tl a product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsitiflity for, the product(s)lis on 0 iis Certificate.AHRI expressly disclaims;all labillity for damages of any"arWng out of the use or performance ofthe product(s),or the unautimmized alleration a'data listed on this Certiticata.certified ratings are valid only for models and configurations listed Inthe directory at TERMS AND CONDITI NS This Certificlite and its cA ntents am proprietary produicts olAHRL This certificate shall only be used for indWidual,personal and confidential reference purposes. The contents of this Cert ficale may not,in whole or m part,be reproduced;copied;lfisseminated;entered into a computer database;or otherwise utilized,in any form or manner or by arn means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFI-ATION The lidon, forthe n odel cited on this certificale can be verified at,— click on link and enter the AHRI Certilleed Reference Number and the data on which the certificate was ssued,which is listed above,and the certificate No,,which is below. @2013 Air-Condit oning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130197783042180565 Designstar Load Calculation Results are intended for use with Rheern heating and cooling systems Street Add ress 1554 linkside dr, Atlantic Beach, FL 32233 Latitude, Longitude 30.3375", -81�76860 House Square Footage: 1210 sq. ft. Name: john vesotski Phone: 123-123-1234 Email: example@maii.com SHR .75 Number of residents 2 Ceiling height 9 Wall U-valu R-value 0.09 11 Floor LI-value R-value 0.2 15 Ceiling U-value I R-value 0.053 1 19 Window U-\alue 0.5 Window SH SF 0.85 Moisture gr3ins 53 Ductloss % 10 Duct gain 0% 10 Cooling infiltraction (ACH) 0.6 Heating infiltration (ACH) 0.8 Winter vent lation 0 Summer ve-itilation 0 !k Outdoor Heating Cooling Dry bulb (01-) 32 93 Dailyrange M Relative hurniclity 50% Moisture difference 53 indoor Heating Cooling Indoor temperature (OF) 70 75 Design temperature differenceff) 38 18 I—I�MMN INN—IM11-11M.a I 1 11411 Area Btuh % ofload Wall 3691 14.9 Floor 7494 30.2 Ceiling 2437 9.8 Windows 3287 13.2 1 nfi I trati on 5645 22.8 System Effi Loss 2255 9.1 Total: 24808 System Efficiency Loss Floor Ceiling Windows Wall Infiltrat on '4FIRIUM IBM ON MINOR, 111111111-pill 111111 111111 NO I I III I Area Btuh % of load Wall 2720 10.3 Ceiling 3399 12.8 Windows 9634 36.3 Sensible In,�iltration 2005 7.6 Latent Infiltration 3650 13.8 System Efficiency Gain 2141 8.1 Internal 2057 7,8 Sensible People Load 460 1.7 Latent People Load 460 1.7 Total: 26526 Sensible lo3d 22416 Latent load 4110 SHR 0.85 Capacity at .75 SHR 2.49 Tons Sensible People Load Latent People Load Sensible Infiltration Internal Windows System Efficiencl Wall Latent Infilbation Ceiling ,�- P Glass (E) 88 sq. ft. Glass (S) 12 sq. ft. Glass (N) 12 sq. ft. Glass (W) 61 sq. ft. Summer 0 tdoor 930F Summer Wet Bulb 770F Summer In oor 750F Summer Design Grains 50% Winter Outdoor 320F Winter Indoor 70OF Sensible Cooling 22,416 Btuh Latent Cool in g 4,110 Btuh Required C oling Airflow 1,019 CFM Sensible Heating 24,808 Btuh Required Heating Airflow 322 CFM