Loading...
1840 Live Oak Ln 2013 HVAC i, CITY OF ATLANTIC BEACH 1 j 800 SEMINOLE ROAD ;) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003238 Date 8/12/13 Property Address . . . . . . 1840 LIVE OAK LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 3 TONS 33K BTU' S ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ VAN DE GUCHTE MAARTEN OCEAN STATE HEAT & AIR, INC. 1840 LIVE OAK LANE 1476 ATLANTIC BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 249-8251 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 111 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/08/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 111 . 00 111 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 115 . 00 115 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 .- //P��h����(904)247-5826 Fax(904)247-5845 OB ADDRESS: l i4p �1 e— UA L Ll - PERMIT# PROJECT VALUE$ 535 MW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity_ Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating- _ Duct Systems: Total CFM REQUIRED ; EPLACEMENT AIR CONDITIONING& HEATING SYSTEM INSAT� N ALLATI Air Conditioning: Unit Quantity�_ Tons Per Unit REQ Heat: Unit Quantity i BTU's Per Unit Seer Rating 15 -UU Duct Systems: Total CFM REQUIRED TIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping-Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within n six month period or work is suspended or abandoned for sic months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property iOwners Name �f r1 {?C��? Phone Number rll-_53w Mechanical Company ()WZVl Office Phone4A-i, lFax - N Co.Address: l '41(k )�4 16wk 11 - �6City nks -c,Vtrc State zip3� License Holder(Print): �-. G" -- State Certification/Registration# Notarized Signature of License Holder f YVETTE P.MORALES Sw and s be re this ' of �_20j NOTARY PUBLIC STATE OF FLORIDA Si a of No Public Comm#EE879174 Expires 312/2017 This combination qualifies for a Federal Energy CERTIFIED,. ', Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. rectory,org it certificate of Product Ratings AHRI Certified Reference Number: 3645939 Date: 8/9/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC536A**30 Indoor Unit Model Number: FV4CN(B,F)003 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 33800 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 33800" Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 20800 VANDEGUCHTE, MAARTEN MC0445 1840 LIVE OAK LN. AB, FL 32233 249-3380 1 SYS C/O 8-12-13 P.atinr7s followed by an aslensk('�indicate a voluntary cerate of previouSly published data,unless accompanied with a bVAS,which indicates an involuntary cerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to.and assumes no responsibility for. the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.orr;. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not.in whole or in part,be reproduced;copied:disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means.except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified attinvw.e"ttridirect.t}rq.ory, ® Air-Conditioning,Heating, click on"l'eriVy Certificate"link and enter the AHRI Certified Reference Number and the date on and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. @2013 Air-Conditioning.. Heating, and Refrigeration Institute CERTIFICATE NO.: 130205312431666370 Desig nStar Load Calculation Results are intended for use with Rheem heating and cooling systems Informatioh Street Address 1840 live oak In, Atiantic Beac,h, FL 32233 Latitude, Longitude 30,337Y, -81,76060 House Square Footage: 1050 sq. ft. N ar ie: vandeguchto Phone: 904-249-3360 Frnail: 4huse Information--.- SHR5 Number of rosideriLs 2 Ceiling height ht 9 Wall U-value -valga aI39 1 Floor U4value R-value 0,2 5 Ceiling U-value -value 0.053 19 ... ........._...... .. ..__.. . Window SHGF 0.05 Moisture grains 53 Duct l cess % 10 Duct gain ;x 10 Cooling infiltraction (ACH) 0.6 Winter ventilation C 5urnriier v( ntilatior iDesian Conditions Outdoor Heating Cooling ;dry bulb (" ) 45 90 Daily range m Relative humidity 0% Moisture difference 5 Indoor Heating Cooling lr,)do r tem erat re ( F) 70 73 Design t m el-aturc difference(" ) 25 1,7 '.Heating f . • Area Stuh % of load Til 2885 0,1 Floor 1.1.635 40.7 Ceiling 2451 8.6 Wi nd ow 3325 1.1,6 nfiltration 5678 19.9 System Efficiency Loss 2597 9,1 Total: 28572 Heating Loads 17:5 72 B ll,I r Ceiling j- system Efficiency Loss Floor , .. Wall i a Windows Infiltration A,, I/ ", VM wgw „.-,WIN al � y , In Area Btuh % of load .. Ceiling 5039 .5, \Nindows 10 14,7 302 Sensible Infiltration 2896 8.6 Latent Infiltration 5581 16J) System Efficiency Gain 2684 Internal 3145 9.4 Sensible People Load 460 1. Latent People Load 46 Tota 1 33587 Sensil,le I o a ld 27547 . ......._... .._. Latent load 6041 SNR X1.5 Capacity at .75 SNR 3.06 'Tans Cool i rig Loads 3 58 l:31.x/h r Sensible People Load Latent People Load r —System Efficiency Gain Windows d' Sensible Infiltration _...—Wall Internal Latent Infiltration \ Ceiling 1111110 AED Graph 15000 5000 0 Barn gam 1.0am 1 lam 3.2pin Ipm 2pm 313i,r) 411m - Hourly Loads Average ............. ................. Eq • ent selection Go- ,v ll ben adt7" isin d vedi Glass (S) 1,34 sq. ft, Glass (W) 19 sq. ft. GI�ss (E) 19 sqft. Glass (N) 94 sq. ft. Summer Outdoor 90"F Sur mer Wet B,ul b 77"F Summer Indoor Summer Design Grains 50% Winter Outdoor 45"T " Winter indoor 70 T Sensible Cooling 27,547 Btuh Latent Cooling 6,041 Btuh 2 Required Cooling Airflow 1,25CFM Sensible Heating 28,572 Btuh Required Heating X r,fl ow 37 1 C F r,,A tds and A I i c a Ic u I !ti U r procedut'es. cude -ntf_M! Q 5tietc`;, syste.,n.s idea