Loading...
1731 Seminole Rd 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003261 Date 8/15/13 Property Address . . . . . . 1731 SEMINOLE RD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2 . 5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LAURIN, SUZANNE R SNYDER HEATING & AIR 10378 NW 6TH CT P.O. BOX 16826 CORAL SPRINGS FL 33071 JACKSONVILLE FL 32245 (904) 32S-9979 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/11/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904)247-5845 13 - OBADDRFss: ?J PERmyr# Jz 6, / PROJECTVALUE$ 'iky90.()` ARI# 19"11 q _REQUIRED Air Handling Equipment Only * &_Air Handling Unit & Condenser Condenser Only MW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity t Tons Per Unit 2e.5 Heat: Unit Quantity BTU's Per Unit So o-.3 Seer Rating_L'�__ Duct Systems: Total CFM REQUIRED PIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) PIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators kLL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BT`U's # Water Heaters Solar Collection Systems Tanks(gallons) Wells )THER: ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I�haeread ds application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or it. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. 'roperty Owners Name '!�� Phone Number 954-kg-tj-9-lxxo-2 4echanical Company 5^,je-r Co . Office Phone u,41-0,pWFax-ioq!:7- 'o.Address: P.O. 9-,Q% Xse�67--kp City Statef-L Zip 'Av%4,�' ,icense Holder(Print): E j i r-, k - 114-f- Certification/Registration#—CAC-A%IV>O-+ i6tarized Signature ofLwense Holder . 21 Before me this day of 20 HOLLY A.FOUST MY COMMISSION#EE 204856 Signature of N EXPIRES:July 21,2016 k1w Ttn UP ANERLS CERTIFIED-,.. ,jww.a hridirec tot y.org --) A Certificate of Product Ratings AHRI Certified Reference Number: 5919027 Date: 8/15/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR303OC1 Indoor Unit Model Number: TEM3AOB3OS31+TDR Manufacturer: TRANE Trade/Brand name: XR13 WEATHERTRON Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh).- 29000 EER Rating (Cooling): 11.50 SEER Rating (Cooling): 13.25 Heating Capacity(Btuh)@ 47 F: 29000 Region IV HSPF Rating (Heating): 8.50* Heating Capacity(Btuh) @ 17 F.- 16700 Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),cirthe unauthorized atterartion of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at ­vw.ahridirectory.oirg. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.aiiridirectory.org, it "111111311 Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on which the certificate was issued,which is listed above,and the Certificate No.,which is listed bekm. 0%0 M ILI and Refrigeration Insfitute @2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130210427570412025 DesignStar Load Calculation Results are intended for use with Rheem heating and cooling systems WVII SU-eet- Adiress Latitude, Longitude U.-Jj i b I fc,b b House Square Footage: 12-40 sq. ft. ............ .................................. Nar-- Phone: 123-12-3-1234 ..........-..- I .............................. ...........................I ............-1-............-------------------------- .................... ---------............................. ...............- Email: example@pmail.com House Information SHR .75 ............................ ............. Number of residents 2 Ceiling height 9 I--,.................---...................................-............ ....... ............ -------- Wall U-value I R-value 0,09 ,111 Floor U-value I R-value 0.215 I............................................................................................. ........................................................................................... Ceiling U-value I R-value 0.0531 19 Window U-value 0.5 ...................... ................................... .............................................. Window SHGF 0.85 hAois4- M sure grains 5-3) Duct IOSS 0/- I �...........I........................ Duct gain % 1 n -.................- ............- ................ ............. .......- Cooling infiltraction (ACH) 0.6 ............................................. Heating infiltration (ACH) 0.8 Winter- ventilation 0 111................................ ...... Summer ventilation 0 Design Conditions Outdoor Heating Cooling ............ .................- ..................- Dry bulb (OF) 1-1-1-............. Daiiy range ........... 1z no/ Relative hurni-dity j%j/U Moisture difference .......... ........................................................................ Indoor Heating Cooling ............ ............. ........... ......... Indoor temperature (OF) ....................I ............--.................................... Design temperature difference(OF) 'Heating Loads Area Btuh % ofload Floor II.--e i I i n g 2497 9.5 Windows 3401 13 I.................................................... ......................................... I nfil Itrati,on 5784 22 System Efficiency Loss 2385 9.1 ............ Total: 26235 Heating Loads 26,235 BTU/hr System Efficiency Loss Ceiling Floor Windows Wall Infiltration Area Btuh % of load Sensible Infiltratiol-. Lak t e n t -1 IF i r a t Orl ........... ........ Internal 2108 7.8 7,7` ...........- .......... Latent People Load 460 1-7 Total: 27183 .................. ........................... Sensible load 22982 Latent load 42'0 1 ..............-................................... ...............-............... ....................I............... SHR 0.85 Capacity at .75 SHR 2.55 ......................... ............................. ................- Cooling Loads 27,183 BTU/hi Sensible People Load Latent People Load Sensible Infiltration Internal Windows -Inl System Efficiencl Wall Latent Infiltration Ceiling Adequate Exposure Diversity AED Graph 15000 10000 5000 0 8arn 9arn loarn 11arn 12pm 1PM 2prn 3pm 4prn 5p?-n 6prn 7prn 8PM Hourly Loads Average Equipment selection System equipment selection will be made using the following derived values. Glass (E) 90 sq. ft. ........... Glass (S) 13 sq. ft. Glass (N) 13 sq. ft. ---.......... Glass (W) 63 sq. ft. Summer Outdoor 930F ...........- ......... .................. Summer Wet Bulb 770F Summer Indoor 75"F ............... .................... ............ ................. .........- Summer Design Grains 50% ........... Winter Outdoor 320F .................... --...........11.................... ................ ........... .............................................. ------------ ............ ....... Winter Indoor 70"F Sensible Cooling 22,982 Btuh Latent Cooling 4,,201 Btuh ..................... .......... Required Cooling Airflow 1,045 CFM Sensible Heating 26,235 Btuh ............ ................. Required Heating Airflow 341 CFM All calculations are based upon approved hvac industry standards and procedures.and comply with all local, state and federal code requirements.All computed results are Estimates.Product provided by Energy Desgn Systems and Idea Tree P owww*41!"two 7MO FLC)RU)A EMERCzy CX)NSERVATM CODE Mund_aaUq-w9uCt ampecum Cenifiaxtim-for HVAC diange-Out ft time ome tow mawment of i"7.Ll Ductseafft )L At unib,8V ugcessMe(amhdomm of30 hwbw(762 mm)ckwwce)joints and MVAC awqxffaluES wd ms in do afr&ddbefte SYBIM"be and sculed v&w meded usmg rmkrwd wow w-code cwtification by the caobwAw*M is attadwd to the air hmWim,unit appmved cqwwafud Md"bwbmb a sibwd Ok ww*has been aCCOMPHSO-C& L Ducts in conMqv�ed space. 2.Joints or semsaut am aheady sealed with Of andwastic..- 3.Ifsystcm is ftsted and repawed as necessmY. cg��Nafo= CMItMCkC UMM*#;; Peanit Number. I c=dfy&ajbwehwp=Iedflwd=t asm=Iedw&theRVAC=itwhwo;cdby*epMM#listed above aW fimad it complies wA&e raphemeigsof Sectim 101.4-7-U as kfizWd�dovr. CI Where needed�the access%le,Msfmg dwft haw becu smded umg zemkrced nrastic or cod*-approved eqdvakuL 0 DUcts am kmftd within Candffimed.qme(Secdcm 101.4.7-1-1 magdonl) 0 Thejainft or seems we ahumdy seafed,wj&fabdc and meWc(Secticm 101_4.7.1_1 C=Cptiou 2) 11 System was tested and repairs were as necessary to be substandaRy leak free. (Secdon I OL4.7.1.1 excqAion 3) N EW-KIALLY LEM F-R=MstWORIUM sygem=w kOxg p=,kr Own 3 eft pw 160 upgam Swt gf==Wmmd floor am at a Fressum oF25 Phsad(Qj@ hm.we_)acruss Um Curwe air Custranfion system, Prhyted Nawne-- Vil Signature: *This fam must be Cosuplated and atbdoW to tM ak InsPecthm ihnn the dtv.