1731 Seminole Rd 2013 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003261 Date 8/15/13
Property Address . . . . . . 1731 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 2 . 5 tons
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
LAURIN, SUZANNE R SNYDER HEATING & AIR
10378 NW 6TH CT P.O. BOX 16826
CORAL SPRINGS FL 33071 JACKSONVILLE FL 32245
(904) 32S-9979
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/11/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)247-5826 Fax (904)247-5845 13 -
OBADDRFss: ?J PERmyr# Jz 6, /
PROJECTVALUE$ 'iky90.()` ARI# 19"11 q _REQUIRED
Air Handling Equipment Only *
&_Air Handling Unit & Condenser Condenser Only
MW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity t Tons Per Unit 2e.5
Heat: Unit Quantity BTU's Per Unit So o-.3 Seer Rating_L'�__
Duct Systems: Total CFM REQUIRED
PIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
PIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BT`U's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I�haeread
ds application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
it. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
'roperty Owners Name '!�� Phone Number 954-kg-tj-9-lxxo-2
4echanical Company 5^,je-r Co . Office Phone u,41-0,pWFax-ioq!:7-
'o.Address: P.O. 9-,Q% Xse�67--kp City Statef-L Zip 'Av%4,�'
,icense Holder(Print): E j i r-, k - 114-f- Certification/Registration#—CAC-A%IV>O-+
i6tarized Signature ofLwense Holder . 21
Before me this
day of 20
HOLLY A.FOUST
MY COMMISSION#EE 204856 Signature of N
EXPIRES:July 21,2016
k1w Ttn UP
ANERLS CERTIFIED-,..
,jww.a hridirec tot y.org --)
A
Certificate of Product Ratings
AHRI Certified Reference Number: 5919027 Date: 8/15/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 4TWR303OC1
Indoor Unit Model Number: TEM3AOB3OS31+TDR
Manufacturer: TRANE
Trade/Brand name: XR13 WEATHERTRON
Manufacturer responsible for the rating of this system combination is TRANE
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh).- 29000
EER Rating (Cooling): 11.50
SEER Rating (Cooling): 13.25
Heating Capacity(Btuh)@ 47 F: 29000
Region IV HSPF Rating (Heating): 8.50*
Heating Capacity(Btuh) @ 17 F.- 16700
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance ofthe product(s),cirthe
unauthorized atterartion of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at vw.ahridirectory.oirg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.aiiridirectory.org, it "111111311 Air-Conditioning,Heating,
click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on
which the certificate was issued,which is listed above,and the Certificate No.,which is listed bekm. 0%0 M ILI and Refrigeration Insfitute
@2013 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130210427570412025
DesignStar Load Calculation
Results are intended for use with Rheem heating and cooling systems
WVII
SU-eet- Adiress
Latitude, Longitude U.-Jj i b I fc,b b
House Square Footage: 12-40 sq. ft.
............ ..................................
Nar--
Phone: 123-12-3-1234
..........-..- I .............................. ...........................I ............-1-............-------------------------- .................... ---------............................. ...............-
Email: example@pmail.com
House Information
SHR .75
............................ .............
Number of residents 2
Ceiling height 9
I--,.................---...................................-............ ....... ............ --------
Wall U-value I R-value 0,09 ,111
Floor U-value I R-value 0.215
I............................................................................................. ...........................................................................................
Ceiling U-value I R-value 0.0531 19
Window U-value 0.5
...................... ................................... ..............................................
Window SHGF 0.85
hAois4-
M sure grains 5-3)
Duct IOSS 0/-
I �...........I........................
Duct gain % 1 n
-.................- ............- ................ ............. .......-
Cooling infiltraction (ACH) 0.6
.............................................
Heating infiltration (ACH) 0.8
Winter- ventilation 0
111................................ ......
Summer ventilation 0
Design Conditions
Outdoor Heating Cooling
............ .................- ..................-
Dry bulb (OF)
1-1-1-.............
Daiiy range
...........
1z no/
Relative hurni-dity j%j/U
Moisture difference
.......... ........................................................................
Indoor Heating Cooling
............ ............. ........... .........
Indoor temperature (OF)
....................I ............--....................................
Design temperature difference(OF)
'Heating Loads
Area Btuh % ofload
Floor
II.--e i I i n g 2497 9.5
Windows 3401 13
I.................................................... .........................................
I nfil Itrati,on 5784 22
System Efficiency Loss 2385 9.1
............
Total: 26235
Heating Loads
26,235 BTU/hr
System Efficiency Loss
Ceiling
Floor
Windows
Wall
Infiltration
Area Btuh % of load
Sensible Infiltratiol-.
Lak t e n t -1 IF i r a t Orl
........... ........
Internal 2108 7.8
7,7`
...........- ..........
Latent People Load 460 1-7
Total: 27183
.................. ...........................
Sensible load 22982
Latent load 42'0 1
..............-................................... ...............-............... ....................I...............
SHR 0.85
Capacity at .75 SHR 2.55
......................... ............................. ................-
Cooling Loads
27,183 BTU/hi
Sensible People Load
Latent People Load
Sensible Infiltration
Internal
Windows
-Inl System Efficiencl
Wall
Latent Infiltration Ceiling
Adequate Exposure Diversity
AED Graph
15000
10000
5000
0
8arn 9arn loarn 11arn 12pm 1PM 2prn 3pm 4prn 5p?-n 6prn 7prn 8PM
Hourly Loads Average
Equipment selection
System equipment selection will be made using the following derived values.
Glass (E) 90 sq. ft.
...........
Glass (S) 13 sq. ft.
Glass (N) 13 sq. ft.
---..........
Glass (W) 63 sq. ft.
Summer Outdoor 930F
...........- ......... ..................
Summer Wet Bulb 770F
Summer Indoor 75"F
............... .................... ............ ................. .........-
Summer Design Grains 50%
...........
Winter Outdoor 320F
.................... --...........11.................... ................ ........... .............................................. ------------ ............ .......
Winter Indoor 70"F
Sensible Cooling 22,982 Btuh
Latent Cooling 4,,201 Btuh
..................... ..........
Required Cooling Airflow 1,045 CFM
Sensible Heating 26,235 Btuh
............ .................
Required Heating Airflow 341 CFM
All calculations are based upon approved hvac industry standards and procedures.and comply with all local,
state and federal code requirements.All computed results are Estimates.Product provided by Energy Desgn
Systems and Idea Tree
P owww*41!"two
7MO FLC)RU)A EMERCzy CX)NSERVATM CODE
Mund_aaUq-w9uCt ampecum Cenifiaxtim-for HVAC diange-Out
ft time ome tow mawment of
i"7.Ll Ductseafft )L At
unib,8V ugcessMe(amhdomm of30 hwbw(762 mm)ckwwce)joints and
MVAC awqxffaluES wd
ms in do afr&ddbefte SYBIM"be and sculed v&w meded usmg rmkrwd wow w-code
cwtification by the caobwAw*M is attadwd to the air hmWim,unit
appmved cqwwafud Md"bwbmb a sibwd
Ok ww*has been aCCOMPHSO-C&
L Ducts in conMqv�ed space.
2.Joints or semsaut am aheady sealed with Of andwastic..-
3.Ifsystcm is ftsted and repawed as necessmY.
cg��Nafo= CMItMCkC UMM*#;;
Peanit Number.
I c=dfy&ajbwehwp=Iedflwd=t asm=Iedw&theRVAC=itwhwo;cdby*epMM#listed above
aW fimad it complies wA&e raphemeigsof Sectim 101.4-7-U as kfizWd�dovr.
CI Where needed�the access%le,Msfmg dwft haw becu smded umg zemkrced nrastic or
cod*-approved eqdvakuL
0 DUcts am kmftd within Candffimed.qme(Secdcm 101.4.7-1-1 magdonl)
0 Thejainft or seems we ahumdy seafed,wj&fabdc and meWc(Secticm 101_4.7.1_1
C=Cptiou 2)
11 System was tested and repairs were as necessary to be substandaRy leak free.
(Secdon I OL4.7.1.1 excqAion 3)
N EW-KIALLY LEM F-R=MstWORIUM sygem=w kOxg
p=,kr Own 3 eft pw 160 upgam Swt gf==Wmmd floor am at a Fressum
oF25 Phsad(Qj@ hm.we_)acruss Um Curwe air Custranfion system,
Prhyted Nawne-- Vil
Signature:
*This fam must be Cosuplated and atbdoW to tM ak
InsPecthm ihnn the dtv.