Loading...
1186 Main St 2013 HVACCITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003248 Date 8/15/13 Property Address . . . . . . 1186 MAIN ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2.5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ SCHOLL HOLLY A ------------------------ DONOVAN HEATING & AIR 1186 MAIN ST 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 322332624 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95.00 Plan Check Fee .00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/11/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2.00 STATE MECH DBPR SURCHARGE 2.00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due -------------------- --------------------------- Permit Fee Total ---------- 95.00 95.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 4.00 4.00 .00 .00 Grand Total 99.00 99.00 .00 .00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247.5826 Fax (904) 247-5845 roB Am tEss• I � SG M C;,yA1 S -r PERMff # PROJECT VALUES Spat AJU# 3(a -S02_18 REQUIRED Air Handling Equipment Only ,_Air Handling Unit & Condenser Condenser Only JEW AIR CONDI'T'IONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating_ Duct Systems: Total CFM REQUIRED ZEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity f Tons Per Unit 2.5 Heat: Unit Quantity I BTU's Per Unit 3o, 000 Seer Rating i' • Z Duct Systems: Total CFM REQUIRED IRE PREVENTION Fire Sprinkler System. Fire Standpipe Underground Fire Main Fire Hose Cabinets Commercial Hoods Fire Suppression Systems 'TRE PLACES Prefabricated Fireplace Qty Gas Piping Outlets LLL OTHER GAS PIPING Quantity of Outlets _ # Vented Wall Furnaces # Water Heaters )THER: Quantity Quantity Value Quantity Quantity Quantity (Requires 3 sets of plans) (Requires 3 sets of plans) (Requires 3 sets of plans) (Requires 3 sets of plans) (Requires 3 sets of plans) (Requires 3 sets of plans) MISCELLANEOUS: Automobile Lz£ts Boilers Elevators/Escalators Heat Exchanger Pumps Refrigerator Condenser Solar Collection Systems Tanks (gallons) Wells BTU's I BTU's !rmit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. i hereby certify that I have read is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or .t. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. roperty Owners Name Phone Number Sg I - � Z p g Ccchanical Company71) J 37fi? Fax 2�, o. Address: �1 icense Halder (Print): _ W, 1 ( . otarized Signature of License Holder City State F1 Zip3Z2_D State Certification/Rcgistration # C'_A 6& 3q-70 '+rf RICHARD PKINS �ir� Before me this % da of 13 ;.= Commission # FF 040399 0399 Y 20 33� Expires July 29, „p. ,,. •' OarkM iimi'my FnM irovmnen RD0aN5.�019 Signature of Notary Public wri httsoft' Project Summary Job: Entire House gy Q` 'ndon zanar a Donovan Heat & Air 315 Cath 8ve South, Jacksonville eeaeh, FL 32260 Phone: 241-3785 Email; brandon(Mdanovnnac.com Project Information For. SCHOLL 1186 Main ST, JACKSONVILLE, FL 32233 Notes -- Design information Weather: Winter Design Conditions Outside db 39 'F Inside dbd Volume (fe) 10962 Design TD 2g °F Heating Summary Equiv. AVF (cfm) 102 Structure 14414 Btuh Ducts 3195 Btuh Central vent (13 cfm) 409 Btuh Humidification 0 Stuh Piping Btuh Btuh Equipment latent load Euiment load 16019 Stuh Infiltration Jacksonville Mayport Naval, FL, US Method Simplified Construction quality Average Fireplaces 1 (Average) Area (ft2 H1fin 219 lin Co 1218 Volume (fe) 10962 10962 Air changes/hour 0,56 0.23 Equiv. AVF (cfm) 102 .42 Heating Equipment Summary Make Tempstar Trade Model TXH530 ARI ref no. 3650218 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 8.5 HSPF 29717 Btuh @ 47T 34 0 801 cfm 0.045 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 95 *F Inside dbe 4674 282 Btuh Btuh Design TD p OF Daily range L Rate/swing multiplier Relative humidity 50 % Moisture difference 53 gr/Ib Sensible Cooling Equipment Load Sizing Structure 14371 Btuh Ducts Central vent (13 cfm) 4674 282 Btuh Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Equipment sensible load 19327 Btuh Latent Cooling Equipment Load Sizing Structure 1921 Btuh Ducts Central vent (13 cfm) 1006 465 Btuh Btuh Equipment latent load 3392 Stuh Equipment total load 22718 Stuh Req. total capacity at 0.70 SHR 2.3 ton Cooling Equipment Summary Make Tempstar Trade Cond TXH530 Coil FXM4X30 ARI ref no. 3650218 Efficiency 15.2 EER Sensible cooling 20906 Btuh Latent cooling 8960 Stuh Total cooling 29866 Btuh Actual air flow 801 cfm Air flow factor 0,042 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0,85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. *}a- wr1}3ht*tp!'*- Right -Sul" Unlvemnl 7.1.01 RSU0$996 ^t -;A C:IUsaralSaleslDoeumentat 2013 -Aug -07 16:43;113 wHgMBott MVAC12.5 TCN Cele = MJti Orientation - N Page 1 Since 1987 CACO 39761 ACO 58398 S 315 Bth Ave. South, JacksonAle 6eacah, FL 32250 "We Want Your Business_ Ghm Us the Opporhmity to EARN IT." 904/241-3785 Fax 241-3745 �-& Fnm omven 14eo. � 14 ►�- F fay q? - 5VS�� - Re: Q Urgent 4 For Review a PIOMW coMMMM,M I o Fly Reply 0 Please Rile Poe Rnves+ ww mdonovanac.com