Loading...
1703 E Park Ter 2013 HVAC CITY OF ATLANTIC BEAQ(I 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Ins) Application Number . . . . . 13-00003249 Date 8/14/13 Property Address . . . . . . 1703 E PARK TER Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ LEE JENNY CLARE & MICHAEL D HUXHAM HEATING & AIR 1703 PARK TER E 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 246-6721 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/10/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. 08/13/2013 10:59 9042460377 HUXHAM HEATING & AIR PAGE 01/01 NftCffi4MC.AL PtRMff,"PL1CAU0N CffY OF ATLANTic BEACH 300 Seminole Rd Aflanfic Beach,FL 32233 Ph(904)247-5926 Fox(904)247-5845 I-�. JoB Aomrass: 1 -7 Lo � I P.�# J 2- PROJECTVALUES KZ00 NEW AM CONDITIONING& MATING SYST7.M INSTALLATION Air Conftonin& Unit quant�y Tons Per unit I-Tvit: Unit Quantity DTE7s Pcr Und Seew FLafing Duct Systftns: Total CFM REQVMED REPLACEMEW AIR CONDMONING & MATING SYSTEM INSTALLATION, AM#37 00 i�VJO Air Conditioning. Unit Qumfity Tons Per Uoit REQUM" Hea: Unit Quantity I BWs Per UE&-v. S=Rating /q Duct SygLems, Toud CFM REQUIRED FIRE PREVENTION Fire Sprinirler System Quantity quires 3 sets of phtns) Fire Stmipipe Quantity uhms,3 we of plans) Undergmnd]Fwc Main Value (Ptquhw 3 wts of plans) Fire Hose Cabimu (Rcquh wo 3 sets of plans) C 1111vidial Hoods Qual3fity CRe4nires 3 sets of plans) Fim Suppression Systems Quantity (Requhw 3 sets of plans) FIREPLACES NUSCELLANEOUS: Prefibricaftd Fireplam Qty— Automobile Lifts Gas Piping OudeLs BOHM BTVS Elevatomffiscalators ALL OTHER GAS PIPING 11"Exdww Quantity of Outlets AMP #Vented Wall Furn=w Rieffigerater Condenser BTIFs #Water Hestem Solar Collmfioa Systems Tanks(pffons) Wells OTHER: or sixmondm I b=by catify anti have mad lf d==3t commaim wrihm a sk =mor wo&ts mqpmded or abm&ned f permit becomm voidif 9 6=Wb*ionandkww&esmwtobetmmdcwrer.L Allplev van becompuWwMwbetha specified ormt The permt d=am vve mwmri"rto vmftthepwiskmofany db"3*k*otlocal kw1%,01stni cunsk=fim or ft pufonmmm oftanstuCfim propedy Ownm Name J--ii, Phowl%mber '16AAM ZY-1--C— f Office Phone 261- mechanical Company ;- �2— - kZ91,FaxjV(p-j0-3?2 . q33 117,,�hvL LkM Stae&--zip-39,-)-5v Co- Addrm* city—A*—Sk� A License HoWer(PM9: S.rm #-cpco!sy,�):s Notmized&gnaWm OfLicenk--Holder ��20 Sv�� wb=amd befi=me this day S" MIRNA AD51JADE-DOWN105i ofNccmy Public LN, Not"pumic-we of Florida my Comm.Expiret oct 21,2016 406 #et 80406 Job: 814131 Project Summary Date: Aug 14,2013 Entire House By: ERIN RODRIGUEZ Project Information For: LEE 1703 PARK TERRACE EAST, ATLANTIC BEACH, FL 32233 Notes: HUXHAM -CHANGE OUT Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 92 'F Inside db 68 'F Inside db 74 oF Design TD 29 'F Design TD 18 'F Daily range L Relative humidity 50 % Moisture difference 60 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19213 Btuh Structure 19213 Btuh Ducts 6782 Btuh Ducts 9316 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25995 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 27674 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1967 Btuh Ducts 2354 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area(ft') 1800 1800 Equipment latent load 4321 Btuh Volume (ft) 14400 14400 Air changes/hour 0.38 0.20 Equipment total load 31995 Btuh Equiv. AVF(cfm) 91 48 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade LEGACY LINE PURON HP Trade LEGACY LINE PURON HP Model 213BN(A,W)042....A Cond 213BN(A,W)042....A AHRI ref 3700426 Coil FV4CN(B,F)005 AHRI ref 3700426 Efficiency 7.8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 28700 Btuh Heating output 39000 Btu h @ 47'F Latent cooling 12300 Btuh Temperature rise 26 'F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Aug-1 4 12 31 28 A—_ + wilrightSOft Right-Suite@ Universal 2012 12A08 RSU01508 Page 1 S\WrightsoftHVAC\Template\HUXHAM-LEE1703.rup Calc=MJ8 FrontDoorfaces. W