Loading...
830 Begonia St 2013 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD s) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 jilt Application Number . . . . . 13-00003169 Date 8/20/13 Property Address . . . . . . 830 BEGONIA ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 CU 1 AHU 3 TONS ---------------------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- SULLIVAN CHARLES A JR & KATHER FLORIDA HOME AIR GOND DBA ARS 830 BEGONIA ST 4211 EMERSON ST ATLANTIC BEACH FL 322331730 JACKSONVILLE FL 32207 (904) 777-4300 ----------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/16/14 --------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 --------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- --- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: 5 &-.qnn-oa Cee- PERMIT# PROJECT VALUE$ BOO ►�Cl) NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARI# 35gy 550 Air Conditioning: Unit Quantity�_ Tons Per Unit -3 REQUIRED Heat: Unit Quantity J BTU's Per Unit s9 Seer Rating 1310 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells J OTHER: �, i O Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.�y Property Owners Name 171 6 ���( //�//1�� f� Phone Number ' !6 IQ—0 736 Mechanical Comtpa/ny 6g.s Fra) (� �T(Jy Office Phone a� ax 7�'7- Co. Address: a�1 C � �� �P f City State Zip�7 License Holder(Print): State Certification/Registration Notarized Signature or License Holder Sworn and subscribed before me th' day of k� 20-0 :o,ArP� ;, CAt„_,�_YN BURNER Signature of Notary Public ._ M` ,gKAISSION#EE061381 v,.= SES M ,y 16,2015 (407)398-015. stvotaryService.wm 9%0 NEU CERTIFIEDT11 r Certificate of Product Ratings AHRI Certified Reference Number: 3544550 Date: 7/25/2013 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 13PJL36 Indoor Unit Model Number: RHSL-HM3617+RCSL-H*3617 Manufacturer: RHEEM MANUFACTURING COMPANY Trade/Brand name: RHEEM 13PJL SERIES Manufacturer responsible for the rating of this system combination is RHEEM MANUFACTURING COMPANY Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (Btuh): 34400 EER Rating (Cooling): 11.00* SEER Rating (Cooling): 13.00 Heating Capacity(Btuh) @ 47 F: 34600 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 22600 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes. The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual,personal and confidential reference. CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, Air-Conditioning,Heating, click on"Verify Certificate"link and enter the AHRI Certified Reference Number and the date on A. On -' and Refrigeration Institute which the certificate was issued,which is listed above,and the Certificate No.,which is listed below. ©2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130192379988122100 Designstar Load Calculation Results are intended for use with Rheem heating and cooling systems ,customer • • Street Address 830 BEGONIA STREET, Atlantic Beach, FL 32233 ............. ...._... _ .................................................._............................_. .............................................................. .............._....... Latitude, Longitude 30.33750, -81.76860 House Square Footage: 1545 sq. ft. Name: KATIE SULLIVAN Phone: 904-412-6720 Email: ..........................................................._............_....................._.....................................................................--...................................._......_........_.............._....._......................--.................._......._........._............ �House Information SHR .75 ....................................................................................................................................................._._.........................................._..........._....._.._........................................................_....... ........ Number of residents 2 ............._.._.._.._..........._................................................................................................................................................................................................._........................-............................................................ ................ Ceiling height 9 Wall U-value R-value 0.09111 ......._............................................._......_............................................._........_.............................._.._.........................................._.........._........_............................_........_......................_.................._.............._... Floor U-value R-value 0.2 15 ........ ........ ...... U-value... � R-value Ceiling0.053 1 19 Window U-value 0.5 Window SHGF 0.85 ...._......._....................._...................._..._.._..._.........................................._............................................................................................................._................................................................................. .................... Moisture grains 53 .......... Duct loss % 10 ......................_----...........................................................-....._.........-...._................_........................................... ............................._.........._.._............................................................._......... Duct gain % 10 Cooling infiltraction (ACH) 0.6 ..................................................._..................................................................................-..........._............................................................._..........._.................................................................... Heating infiltration (ACH) 0.8 _....._ Winter ventilation 0 ................................................................................................................_.........................................................._..................................._....................._................... Summer ventilation 0 . ......................................................... .. . ........ ............ .... .............. Desiqn Conditions ..................._.. outdoor Heating Cooling Dry bulb (°F) 32 93 ................................................._..........._........................................_......_..._.............. Daily range M ............... ................ __ _.........................._........__........__..........._......._...._..... Relative humidity 50% ................................................._..............................................................._......................................................._................_.._.._......._.........._..................... Moisture difference 53 .................._.._......._........................._...................._............................................_.._.. _ IndoorHeating Cooling .................................................. Indoor temperature (°F) 70 ....................._.._..._............................._..._................_........................._..........._..........__............................................................................._.._............___... Design temperature difference(OF) 38 18 _....................... 'Heating Loads AreaBt...........................__.._..._......._........... Wall 4012 13.9 ................................................................._............................_.....__.............................. ........... Floor 7395 25.5 Ceiling 3112 10.7 Windows 4598 15.9 Infiltration 7207 24.9 ._......................_-...._............................._.._.._.........................._...__._................................_........._..._.._................_....... System Efficiency Loss 2632 9.1 ............................................._....................................._.................................._.......................................... Tota I: 28956 ....................................-.-.................................--...................................._............................................. Heating Loads 28,956 BTU/hr System Efficiency Loss Floor Ceiling Wall Infiltration J \ Windows r :lCoolingLoads Area Btuh % of load Wall 2956 8.6 ..................._........_................................................_......._.__1 .... _..,.__.........-.........._ Ceiling 4340 12.6 ........... ...._..._._._...__._ _...._..._.._. Windows 13503 39.3 ._............................................_..._.-.-_......_._............_........- _.........-.....__.. ....._...... ..._........ Sensible Infiltration 2560 7.4 .......__.................................__..........................._...,..._..... .. _ _....._..._.. Latent Infiltration 4661 13.6 System Efficiency Gain 2802 8.2 Internal 2627 7.6 ................._.....,_......._.................... .........._.._........................_......._.................................... ._... Sensible People Load 460 1.3 __ -1- ................................................................. _ _._........................... Latent People Load 460 1.3 Total: 34369 .._............._.................._...................._......._................_..._............_....................._.._..........._............................ Sensible load 29248 Latent load 5121 _....._.I................ ......_..................... ........._._..........................._........................................._........._............ ._ SHR 0.85 Capacity at .75 SHR 3.25 Tons Cooling Loads 34,369 BTU/hr Sensible People Load Latent People Load �—Sensible Infiltration Internal Windows �\ System Efficiency Wall Ceiling Latent Infiltration AED Graph 20000 15000 0 10000 5000 0 8am 9am loam llam 12pm 1pm 2pm Spm 4pm Spm bpm 7pm Bpm —Hourly Loads —Average Equipment • System equipment selection will be made using the following derived values. Glass (E) 121 sq. ft. ................. Glass (S) 16s q ft. --..................................................................................................................................... Glass (N) 16 sq. ft. Glass (W) 89 sq. ft. ..................................................._....._..._..........................................._............................................................. Summer Outdoor 93°F .........................._.......................I........-..._.._.._.._............................................................................._........ Summer Wet Bulb 77°F __I 1_ _................_..._.................................._.............................................................................._... Summer Indoor 75°F ............... .................................................................................-..............._..................._.................. Summer Design Grains 50% ...........- ......_..... ................................_.................................._......................._...................... Winter Outdoor 32°F .... . ...._ _.. _.....__._._..._._.............._. _.___. WinterIndoor 70°F ...................................................--................... Sensible Cooling 29,248 Btuh Latent Cooling 5,121 Btuh ................................._....................._.................... Required Cooling Airflow 1,329 CFM Sensible Heating28,956 Btuh Required Heating Airflow 376 CFM ----.................................._.._.._...._._.._.............................._... ..............._...................._..._.........._............... All calulations ae bad upon hvac standars and es,and ly with ll local, state acnd ederalrc des re quiirements.All computed results are Estima ess.Product rprov ded by Energy a EnergyDesign Systems and Idea Tree