366 Plaza 2013 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD U ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 13-00003283 Date 8/20/13 Property Address . . . . . . 366 PLAZA Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ FOGG MICHAEL L HUXHAM HEATING & AIR 366 PLAZA 2101 FLORIDA BLVD. ATLANTIC BEACH FL 32233 NEPTUNE BEACH FL 32266 (904) 246-6721 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/16/14 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 J Ph(904)247-5826 Fax(904)247-5845 JOB ADDRESS: "I PERMIT# PROJECT VALUE S y 3W NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION ARl# 3(c7 SI Air Conditioning: Unit Quantity l Tons Per Unit 3,S REQ IRED Heat: Unit Quantity t BTU's Per Unit 4/ S a7o Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION (Requires 3 sets of plans) Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity lana Underground Fire Main Value ��l sires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace QtyAutomobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: m wmt is suspended or abandoned for six months.I hereby certify that I have read Permit becomes void.if work does not commence a six month period ibis work will be complied with whether specified this application and know the same to be tree and omrect All provisions of laws ad ordinances g° omrartoe of construction. or not The permit does not give authoridy to violate the provisions of any otber daft or local law regr8 hm mon err the perf Phone Number Property Owners Name � J ' A,� Office Phone�Faxa�y� -037 Mechanical Company T/v���4m Co. Address: �fJf �oy� City ACA State��• Zip License Holder(Print): �' State Certification/Registration#X57815 Notarized Signature of License Hol o and subscribed before this day of u,� 2013 - 1 r n""•4 MMNA A08MAOE-r". WUNQ '•= Notary Putty-Statf ftorW$ tore of Notary Public sr aa=My Comm.Expires O2016 dF•' commission#�EE 845406 Job: 81913 r' Project Summary Date: Aug 19,2013 Entire House By: ERIN RODRIGUEZ • - • • For: FOGG 366 PLAZA DRIVE, ATLANTIC BEACH, FL 32233 Notes: HUXHAM -CHANGE OUT Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 68 °F Inside db 74 °F Design TD 29 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 18804 Btuh Structure 18704 Btuh Ducts 7233 Btuh Ducts 10228 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26037 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 28064 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2170 Btuh Ducts 2565 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 1986 1986 Equipment latent load 4735 Btuh Volume (ft) 15885 15885 32799 Btuh Air changes/hour 0.46 0.20 Equipment total load Equiv. AVF (cfm) 121 53 Req. total capacity at 0.70 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade PREFERRED SERIES PURON HP Trade PREFERRED SERIES PURON HP Model 225BNA042`**'A Cond 225BNA042 A AHRI ref 3677451 Coil FV4CN(B,F)005 AHRI ref 3677451 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15.5 SEER Heating input Sensible cooling 29400 Btuh Heating output 41500 Btuh @ 47°F Latent cooling 12600 Btuh Temperature rise 27 °F Total cooling 42000 Btuh Actual air flow 1400 cfm Actual air flow 1400 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2013-Aug-19 23 23.50 A_ viori+ghtSOfft" Right-Suite®Universal 2012 12.1.08 RSU01508 Page 1 AM ents\Wrightsoft HVAC\Template\HUXHAM-FOGG.rup Calc=MJ8 Front Door faces. N