Application Number . . . . . 13-00003317 Date 8/26/13
Property Address . . . . . . 830 BEGONIA ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SULLIVAN CHARLES A JR & KATHER DONOVAN HEATING & AIR
830 BEGONIA ST 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 322331730 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 2/22/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax(904) 247-5845
FOB ADDRESS: i T PERMIT#
PROJECT VALUE $ �l3`1 U 01� ARI#5L n B5� REQUIRED
Air Handling Equipment Only 4Air Handling Unit & Condenser Condenser Only
4EW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit Seer Ratin
Heat: Unit Quantity BTU's Per Unit gREQUIRED
Duct Systems: Total CFM
1EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit 3 15
Heat: Unit Quantity I BTU's Per Unit�� Seer RatingREQUIRED
Duct Systems: Total CFM
?IRE PREVENTION 3 sets of plans)
Fire Sprinkler System Quantity (Requires
Fire Standpipe Quantity requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
?IRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
kLL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
)THER:
ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
lis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the rovisions of any other state or local law regulation construction or the performance of construction.
'ro erty Owners Name v 1 0 Phone Number 5� _x,'"1_ _
P
dechanical Company. 1 OY�d�I�� i E 1kt' ��� Office Phone�Yl 3'l8�Fax 2 ft �
:o. Address: 3�S le P S City a�a,�State�Zip=-5-6—
,icense Holder(Print)• l 1 n. N State Certification/Registration#
Votarized Signature of License Holder �j
RICHARD TOMPKINS Before me this _day o t/ v 20—�_._.
° commission#FF 040399
Expires July 29,2017 Signature of Notary Public
�, ,_n Trey, i insmarce 800-385-7019
Job:
+ wrigihtsoft Project Summary Date: August 22,2013
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S, Jacksonville Beach, FL 32250 Phone 904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project • •
For: Magg'e Sullivan
830 Begonia St,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 95 OF
Inside db 70 OF Inside db 75 OF
Design TD 31 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26705 Btuh Structure 20836 Btuh
Ducts 4945 Btuh Ducts 4814 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31649 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 25651 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1154 Btuh
Fireplaces 0 Structure
Ducts 2066 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area (ft') 1040 1040 Equipment latent load 3220 Btuh
Volume (ft3) 8320 8320
Btuh
Air changes/hour 0.45 0.23 Equipment total load 28871.1 ton ton
Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 15 SEER N SERIES R41 OA HP Trade
15 SEE GNS�
Coil FXERIES R410A HP
Model NXH536GKA` H536GKA
AHRI ref no3670858 Coil ref noFXM4 *A'
8
Efficiency 8.7 HSPF Efficiency 12.5 EER. 15 SEER
Heating input Sensible cooling 24360 Btuh
Heating output 35400 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 28 OF Total cooling 34800 Btuh
Actual air flow 1160 cfm Actual air flow 1160 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2013-Aug-22 14:42:18
+ wrightsoft Right-SuReO Universal 8 0.24 RSU05995 Page 1
,4'C3'` C:\Users\Owner\Documents\Wrightsoff HVAC\Bogus 3 ton rup Calc=MJ8 Front Door faces: W