850 14th Street West HVAC 2013 CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 13-00003355 Date 9/04/13
Property Address . . . . . . 850 W 14TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
2 . 5 tons 30K btu' s
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
LYON, JONATHAN R TROPIC HEATING & AIR
1837 SEA OATS DR 750 MAYPORT RD
ATLANTIC BEACH FL 32233 ATLANTIC BEACH FL 32233
(904) 241-1788
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 9S . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . - 3/03/14
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph (904)247-5826 Fax(904)247-5845
JOB ADDRESS: S570 Vj 14" ��+ PERmyr
PROJECTVALUE $ ��5V
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
ARI#
Air Conditioning: Unit Quantity Tons Per Unit 2 REQUIRED
Heat: Unit Quantity I BTU's Per Unit 3" Seer Rating 13�
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refterator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified
or not. The permit does not give authority to violate die provisions of any other state or local law regulation construction or the performance of construction.
-7 —/
Property Owners Name 3-0/v Lqcw, Phone Number X' 19
Mechanical Company Tropic Htg and A/C Office Phone 241-1788 Fax 241-2172
Co. Address: 750 MUport Road City Ad. Bch State FL_Zip 32233
License Holder(Print): Charlie Marks S C *fication/Registration# CAC052431
Notarized Signature of License Holder U,01 . !W
Swom and subscri efore me this day of �R-pkff7 b-C 20.
KAREN E.PANTFOEDER Signature of Notary Publicl!z�/
NOTARY PUBLIC
STATE OF FLORIDA
Comm#EE064448
Expires 3/4/2015
L-An'MICERTIFIEDT.
Lwww.ahridirectory.org A'
Cleftificate of Product Ratings
AHRI Certified Reference Number: 3699906 Date: 9/4/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 213BN(A,W)030****A
Indoor Unit Model Number: FB4CNF030
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY LINE PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity(Btuh)-. 30000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F 30000
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh) @ 17 F 18300
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the prGduct(s),or the
unauthorized alteration of data listed on this Certificate.Cenified ratings are valid only for models and configurations listed in the directory at��nvw,ahrtdireciory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference.
CERTIFICATE VERIFICATION
The information forthemodel cited onthis certificate ran beverified atwww.ahridirectory.org, it tAnI Air-Conditioning,Heating,
clickon"Verify Certificate"linkand entertheAHRI Certified Reference Numberand the dateon Paw ims *1 and Refrigeration Institute
which the certificate was issued,which is listed above,and the Certificate No�,which is listed below.
@2013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130227970605184890
AMIN CERTIFIED,.7
www.a h rid ire ctory.a rg
L- -_______--.A
Ceftificate of Product Ratings
AHRI Certified Reference Number: 3699906 Date: 9/4/2013
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 213BN(A,W)030****A
Indoor Unit Model Number: FB4CNF030
Manufacturer: BRYANT HEATING AND COOLING SYSTEMS
Trade/Brand name: LEGACY LINE PURON HP
Manufacturer responsible for the rating of this system combination is BRYANT HEATING AND COOLING
SYSTEMS
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh)-. 30000
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @ 47 F: 30000
Region IV HSPF Rating (Heating): 7.70
Heating Capacity(Btuh) @ 17 F 18300
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibilityfor,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at,�ivvw.ahridirectoryorg.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.
The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated;entered into a computer database;or otherwise utilized,in any
form or manner or by any means,except for the user's individual,personal and confidential reference�
CERTIFICATE VERIFICATION
The Information for the model cited on this certificate can be verified at www.ahvidirectory.org, Aunp, Air-Conditioning, Heating,
dick on"Verify Certificate"linkand entertheAHRI1 Certified Reference Number and the dateon NMI No ILI and Refrigeration Institute
which the certificate was issued,which is listed above.and the Certificate No�,which Is listed below.
02013 Air-Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: 130227970605184890
Job: Lon
Right J@ Mobile Report Date: 914/2013
43 Entire House By: Tropic Heating&Air C...
Tropic Heating & Air Conditioning, Inc.
Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CAC052431
Project Information
For: Lyon,John, Tropic Heating&AirConditioning,lnc.
850 14 th St., Atlantic Beach, FIL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email:TropicacCa msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature(-F) 70 75
Elevation: 43 ft Design TD('F) 35 16
Latitude: 30'N Relative humidity(%) 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Dailyrange('F) - 17 ( M Method Simplified
V�bt bulb('F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Ems=
Component Btu h/ft2 Btuh %of load
Walls 4.9 4972 22.1 W13
Glazing 30.1 3462 15A VWIS
Doors 13.5 433 1.9
Ceilings 1.7 1953 8.7
Floors 4.1 4773 21.2 IrfiqrAcn
Infiltration 2.3 2627 11.7
Ducts 4284 19.0 G m rTg
Piping 0 0
Humidification 0 0 cd-ffr
Ventilation 0 0 Cdirgs
Adjustments 0
Total 225041 100.0 1
N-
Component Btu h/ft2 Btuh %of load
Walls 2.6 2601 13.1 V\dIS Irtard Gins
Glazing 37.9 4355 22.0
Doors 11.4 367 1.8
Ceilings 2.6 2980 15.0
Floors 2.0 2248 1 1.3 Gdng, Ducts
Infiltration 0.5 632 3.2
Ducts 4536 22.9
Ventilation 0 0
Internal gains 2120 10.7
Blower 0 0 aher Infiltration
Adjustments 0 Ceilirr
Total 19840 100.0 gs Flocrs
Latent Cooling Load 2987 Btuh
Overall U-value=0.213 Btuh/ft2-'F
Data entries checked.
AJ I 2013-Sep-04 12:32:30
-r7- wrilghtSOft Right-Suite@ universal 2013 13.0.04 Right JO Mobile Page I
,OCCk ...\wstmp\7fa2cdl6-e3f2-4537-89ff-551948cbf68d.rup Calc=MJ8 Front Door faces: N
Project Summary Job: Lon
Date: 9/412013
Entire House By: Tropic Heating&Air C
Tropic Heating & Air Conditioning, Inc.
Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431
Project Information
For: Lyon, John, Tropic Heating&AirConditioning,lnc.
850 14 th St.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Notes: Email: Tropicac@msn.com
Design Information
Weather: Jacksonville/Craig, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 35 'F Outside db 91 'F
Inside db 70 'F Inside db 75 'F
Design TD 35 'F Design TD 16 'F
Daily range M
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 18219 Btuh Structure 15304 Btuh
Ducts 4284 Btuh Ducts 4536 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22504 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19840 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2067 Btuh
Ducts 920 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 1152 1152 Equipment latent load 2987 Btuh
Volume(ft3) 9216 9216
Air changes/hour 0.45 0.23 Equipment total load 22827 Btuh
Equiv. AVF(cfm) 69 35 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make n/a Make
Trade n/a Trade
Model n/a Cond
AHRI ref n/a Coil
AHRI ref
Efficiency n/a Efficiency 0 SEER
Heating input 0 Btuh Sensible cooling 0 Btuh
Heating output 0 Btuh Latent cooling 0 Btuh
Temperature rise 0 'F Total cooling 0 Btuh
Actual air flow 909 cfm Actual air flow 909 cfrn
Air flow factor 0.040 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2013-Sep-04 12:32:30
-,T- wrightSOft Rig ht-Suitee u niv ersal 2013 13.0.04 Right JO Mobile Page 1
...\wstmp\7fa2cdl6-e3f2-4537-89ff-551948cbf68d.rup Calc=MJ8 Front Door faces N
j@ Worksheet Job: Lon
Right- Date: 9/412013
Entire House By: Tropic Heating&Air Condi...
Tropic Heating &Air Conditioning, Inc.
Atlantic Beach,FIL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.com License:CAC052431
Entire House First Floor
name 144.0 ft 144.0 ft
cxposed wall 8.0 ft d 8.0 ft heat/cool
3 Room height 48.0 x 24.0 ft
4 Room dimensions 11510 ft2 1152.0 ft2
5 Room area
Area Load Area (ft2) Load
Construction e I or HTM (f t') (ft) (Btuh) or perimeter (ft (Btuh)
number (BUtuva,fut' F) (Btuh/ft or perimeter Gross Cool
Cool Gross NIP/S Heat Cool
1710 895 1710 895
13A-4ocs 0,143 n 4.95 2 1154 893 38 1154 893
6 0.870 n 30.10 202991 :3 855 447
8
t---G 1 D-c2om e 4�95 2.59 E 855 447 577 1199
0.143 �2 1773 1792 173
13A-4ocs 0.870 e 30.10 6256 19 0 577 1199 19 0 812
t--G 1 D-c2om 384 314 1552 812 384 314 1552
11 V 13A-4ocs 0.143 s 4.95 2.59 0 1154 1064 38 0 1`154 1064
1 D-c2om 0.870 s 30.10 27.75 38 32 433 367 32 32 433 367
L::2 11DO 0.390 5 13.49 11.43 32 173 855 447 173 655 447
VL_G 13A-4ocs 0.143 w 4.95 2,59 192 11991
0.870 w 30.10 62.56 19 0 577 1199 19 0 577
1 D-c2om 0.049 1.70 259 1152 1152 1953 2980 1152 1152 1953 29801
C 1613-19ad 0.368 4.14 1�95 1152 1152 4773 2248 1152 1152 4773 2248
F 1 9A-OcvtD
0 0
c)AED excursion 15593 12551 15593 12551
2627 632 2627 632
12 a) Infiltration 0 0 0
b) Room ventilation 230 4 920 4 920
13 internal gains. Occupants @ 1200 1200
Appliances/other lQ8219 153 182191 1 04
1 Subtotal(lines 6 to 13) 0 0 0
Less external load 0 0 0
Less transfer 0 0
Redistribution 18219 15304 18219 15304
14 Subtotal 42134 4536 24% 30% 4284 4536
15 Duct loads 2251341 198401
225N 198401 909 909
Tot I room load 909 909 1
Air arequired(cfm)
Calculations awrove by ACCA to meet all requirements of Manual J 8th Ed. 2013-Sep-04 12:3230
wrightSC30ft Right-Suite@ Universal 2013 13.0.04 Right J@ Mobile Pagel
...Nwstmp\7fa2cdl6-e3f2-4537-89ff-5510,48cbf6gd.rup calc=MJ8 Front Door faces� N
Job: Lon
Component Constructions Date: 914/2013
Entire House By: Tropic Heating&Air C...
Tropic Heating & Air Conditioning, Inc.
�d,Atlantic Beach,FL 32233 Phone:904-241-17a8 Fax:904-241-2172 Email:Tropicac@msn.00m lJoense:CAC052431
Project Information
For: Lyon, John,Tropic Heating&AirConditioning,lnc.
850 14 th St.,Atlantic Beach, FL 32233
Phone- 904-241-1788 Fax 904-241-2172
Email: Tropicac@msn.com
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature('F) 70 75
Design TD('F) 35 16
Elevation: 43 It '.10 50
Latitude: 30'N Relative humidity(%)
Outdoor: Heating Cooling Moisture difference (gr/lb) 8.4 52.8
Dry bulb('F) 35 91 Infiltration:
Daily range('F) - 17 M Method Simplified
Wetbulbff) - 77 Construction quality Average
Wind speed (mph) 15.0 7.5 Fireplaces 0
Or Area U-value Insul R Htg HTM Loss Cig HTM Gain
Construction descriptions ft� Rh/ft'-'F ft2- F/Rdl 2th/ft2 Btuh Rtuh/ft2 Bt,h
Walls 1710 2.59 895
13A-4ocs:Blk wall,stucco ext, r-4 ext bd ins,6"thk, 1/2"gypsum n 346 0.143 4.0 4.95
e 173 0.143 4.0 4.95 855 2.59 447
board int fnsh s 314 0.143 4.0 4.95 1552 2.59 812
w 173 0.143 4.0 4.95 855 2.59 447
all 1005 0.143 4�O 4�95 4972 2.59 2601
Partitions
(none)
Windows 1154 213 893
1 D-c2om�2 glazing,cIr outr,air gas,mt]no brk frm mat,cir innr, 1/4" n 38 0�870 0 30.1
e 19 O�870 0 30.1 577 6Z6 1199
gap, 1/8"thk;50% blinds 45o, light s 38 0.870 0 30.1 1154 27.8 1064
w 19 O�870 0 30.1 577 62.6 1199
all 115 0.870 0 30.1 3462 37.9 4355
Doors s 32 0.390 0 13.5 433 11.4 367
11 DU Door,wd sc type
Ceilings 1.70 1953 2.59 2980
1613-19ad:Attic ceiling,asphalt shingles roof mat, r-19 cell ins, 1/2' 1152 0.049 19.0
gypsum board int fnsh
Floors 4773 1.95 2248
19A-Ocvtp Fir floor,wd fir, 1"thkns.tile fir fnsh,leaky crwl ovr 1152 0.368 0 4.14
2013-Sep-04 12:3230
+ wrightSOft Right-Suitea Universal 2013 13.0.04 Right J&Mobile Page I
ACCN ,.\wstmp\7fa2cdl6-e3f2-4537-89ff-551948cbf68d.rup Cale=MJ8 Front Door faces: N
Job: Lon
AED Assessment Date: 9/4/2013
Entire House By: Tropic Heating&Air C...
Tropic Heating & Air Conditioning, Inc.
Rd,Atlantic Beach,FL 32233 Phone:904-241-1788 Fax:904-241-2172 Email:Tropicac@msn.00m License:CAC052431
Project Information
For: Lyon, John, Tropic Heating&AirConditioning,lnc.
850 14 th St.,Atlantic Beach, FL 32233
Phone: 904-241-1788 Fax: 904-241-2172
Email: Tropicac@msn.com
Design Conditions
Indoor: Heating Cooling
Location: Indoor temperature(oF) 70 75
Jacksonville/Craig, FL, US Design TD('F) 35 16
Elevation: 43 ft Relative humidity 30 50
Latitude: 30oN Moisture difference(gr/lb) 8.4 52.8
Outdoor: Heating Cooling
Dry bui b('F) 35 91 Infiltration:
Dailyrange('F) - 17 ( M
Wet bulb('F) - 77
Wind speed (mph) 15.0 7.5
Irm a FewTo Min U.1
Hourly Glazing Load
7,00
6,00
5,00
4100
3,00
2,00
1300
0 8 9 10 11 1�2 1'3 14 15 16 17 1'8 19 20
Hour of Day
Houdy Aerage AMjinit
Maximum hourly glazing load exceeds average by 19.7%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
2013-Sep-04 12:32 30
+ wright!50ft Right-SuiteO universal 2013 13�0.04 Right JO Mobile Page 1
A:�C*k ...�wstmp�7ta2cdlr�-e3f2-4537-89ff-551948cbf68d.rup CaIC=MJ8 Front Door faces: N